Assessment of mitral regurgitant jets by three-dimensional color Doppler

被引:19
|
作者
De Simone, R
Glombitza, G
Vahl, CF
Albers, J
Meinzer, HP
Hagl, S
机构
[1] Univ Heidelberg, Abt Herzchirurg, Dept Cardiac Surg, D-69120 Heidelberg, Germany
[2] Deutsch Krebsforschungszentrum, Dept Med & Biol Informat, D-6900 Heidelberg, Germany
来源
ANNALS OF THORACIC SURGERY | 1999年 / 67卷 / 02期
关键词
D O I
10.1016/S0003-4975(98)01096-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Color Doppler echocardiography is a standard technique for assessing mitral regurgitation before and after mitral valvuloplasty. Mitral valve prolapse produces complex eccentric jet flows that cannot be visualized and measured by two-dimensional color Doppler echocardiography. The aim of this study was to evaluate the clinical impact of three-dimensional color Doppler echocardiography, a new technique developed at our institution for assessing mitral regurgitation. Methods. Forty-five patients with mitral regurgitation underwent intraoperative transesophageal echocardiography and three-dimensional Doppler data acquisition The grade of mitral regurgitation was assessed by angiography. The jet areas were calculated by planimetry from conventional color Doppler; the jet volumes were obtained by three-dimensional Doppler data, Results. New patterns of mitral regurgitant flows were recognized according to the origin, direction, and spatial spreading into the left atrium. Conventional jet areas failed to separate the groups of patients with different degrees of regurgitation, whereas the jet volumes were able to divide patients with different regurgitation grades. No significant correlation was found between jet area and angiographic grading (r = 0.63, p = NS). Jet volumes were significantly correlated to angiography (r = 0.89, p < 0.001). Conclusions. Three-dimensional color Doppler echocardiography revealed new patterns of regurgitant now and allowed a more accurate semiquantitative assessment of complex asymmetrical regurgitant jets. (C) 1999 by The Society of Thoracic Surgeons.
引用
收藏
页码:494 / 499
页数:6
相关论文
共 50 条
  • [31] Three-dimensional echocardiographic reconstruction of mitral valve color Doppler flow events
    Irvine, T
    Derrick, G
    Morris, D
    Norton, M
    Kenny, A
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (09): : 1103 - +
  • [32] Quantitative assessment of regurgitant flow with total digital three-dimensional reconstruction of color Doppler flow in the convergent region: In vitro validation
    Coisne, D
    Erwan, D
    Christiaens, L
    Blouin, P
    Allal, J
    Barraine, R
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (03) : 233 - 240
  • [33] Proximal Flow Convergence Method by Three-Dimensional Color Doppler Echocardiography for Mitral Valve Area Assessment in Rheumatic Mitral Stenosis
    Alberto de Agustin, Jose
    Mejia, Hernan
    Viliani, Dafne
    Marcos-Alberca, Pedro
    Juan Gomez de Diego, Jose
    Javier Nunez-Gil, Ivan
    Almeria, Carlos
    Luis Rodrigo, Jose
    Luaces, Maria
    Angel Garcia-Fernandez, Miguel
    Macaya, Carlos
    Perez de Isla, Leopoldo
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (08) : 838 - 845
  • [34] Three-dimensional echocardiographic assessment of annular dimension, shape, and dynamics in the normal and regurgitant mitral valve
    Kaplan, S
    Sheehan, FH
    Munt, B
    Sivarajan, M
    March, MZ
    Bolson, EL
    Martin, RW
    Bashein, G
    ANESTHESIA AND ANALGESIA, 1998, 86 (04): : SCA121 - SCA121
  • [35] SOURCES OF VARIABILITY FOR DOPPLER COLOR FLOW MAPPING OF REGURGITANT JETS IN AN ANIMAL-MODEL OF MITRAL REGURGITATION
    HOIT, BD
    JONES, M
    EIDBO, EE
    ELIAS, W
    SAHN, DJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (07) : 1631 - 1636
  • [36] Three-dimensional echocardiographic assessment of annular dimension, shape, and dynamics in the normal and regurgitant mitral valve
    Kaplan, S
    Sheehan, FH
    Bashein, G
    Munt, B
    Sivarajan, M
    Zeppa, ML
    Bolson, EL
    Martin, RW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 284A - 284A
  • [37] Aliasing-tolerant color Doppler quantification of regurgitant jets
    Stewart, SFC
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06): : 881 - 898
  • [38] Color Doppler and three-dimensional ultrasound in the assessment of early human development
    Kurjak, A
    Kupesic, S
    Kos, M
    Bekavac, I
    Funduk-Kurjak, B
    PERINATAL MEDICINE OF THE NEW MILLENNIUM, 2001, : 233 - 239
  • [39] Diagnostic value of mitral regurgitant jet volume in the assessment of mitral regurgitation severity by general imaging three-dimensional quantification
    Wang, Wugang
    Jiang, Yong
    Li, Junfang
    Gong, Kun
    Zhao, Liang
    Tang, Guozhang
    Meng, Yuanyuan
    Wang, Zhibin
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (10): : 1963 - 1972
  • [40] Diagnostic value of mitral regurgitant jet volume in the assessment of mitral regurgitation severity by general imaging three-dimensional quantification
    Wugang Wang
    Yong Jiang
    Junfang Li
    Kun Gong
    Liang Zhao
    Guozhang Tang
    Yuanyuan Meng
    Zhibin Wang
    The International Journal of Cardiovascular Imaging, 2020, 36 : 1963 - 1972