Enhanced Cerebral Blood Flow and Hemodynamic Status with an Alternative Left Ventricle Chest Compression Position during Cardiopulmonary Resuscitation in Swine

被引:0
|
作者
Marshall, Rory A.
Morton, Jude S.
Luchkanych, Adam M. S.
El Karsh, Yehia
El Karsh, Zeyad
Morse, Cameron
Turnbull, Katie Y.
Schaefer, Niei N.
Tomezak, Corey R.
Grunau, Brian E.
Olver, T. D.
机构
[1] Biomedical Sciences, Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon
[2] College of Kinesiology, University of Saskatchewan, Saskatoon
[3] Department of Emergency Medicine, University of British Columbia, Vancouver
来源
FASEB JOURNAL | 2022年 / 36卷
关键词
D O I
10.1096/fasebj.2022.36.S1.R2076
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
INTRODUCTION: The standard chest compression (SCC) position for cardiopulmonary resuscitation (CPR) is the centre of the chest and typically central to the aortic root. An alternative left ventricle chest compression (LVCC) position may facilitate superior global blood flow. We tested the hypothesis that, consistent with improved ETCO2 (indicative of cardiac output) and blood pressure (BP), LVCC would promote greater cerebral blood flow (CBF) than SCC. METHODS: Female pigs (N=32; 35±2kg) were rotated systematically to receive either SCC (n=14) or LVCC (n=18). Transthoracic echocardiography was used to identify and externally mark: (1) the SCC position, the midline at the level of the aortic route, or (2) the LVCC position, the midpoint of the left ventricle. After 2 minutes of untreated asphyxiated cardiac arrest (CA), swine were treated with three 2-minute cycles of mechanical chest compressions (LUCAS III). ETCO2 (in-line sampling), BP (arterial catheter line), and CBF velocity (CBFv, transcranial Doppler, primary outcome) were measured during the pre-CA, untreated-CA, and CPR-treated phases. Between-group outcomes were compared using a mixed model ANOVA with significant differences considered at P<0.05 and data are presented as mean±standard deviation. RESULTS: Pre- and untreated-CA ETCO2 , BP and CBFv were similar between the SCC and LVCC groups (P>0.100). During CPR, ETCO2 (36±6 mmHg versus 24±10 mmHg; P<0.001), Mean Arterial Pressure (MAP; 49±9 mmHg versus 37±9 mmHg; P=0.002), and Mean CBFv (11±5 cm/s versus 5±2 cm/s; P<0.001) were significantly higher in the LVCC, versus SCC, group. CONCLUSION: In comparison to SCC,LVCC resulted in higher ETCO2 , MAP, and Mean CBFv values throughout CPR in a swine model of CA. NEW AND NOTEWORTHY: We provide novel evidence that compared with mechanical compressions performed over the centre of the chest, compressions performed over the left ventricle promote greater CBF during BLS CPR. Clinical validation of these results may improve survival rates and attenuate neurological deficits following CA. © FASEB.
引用
收藏
页数:2
相关论文
共 50 条
  • [21] THE HEMODYNAMIC INFLUENCE OF RHYTHMIC ABDOMINAL LIFTING AND COMPRESSION DURING CARDIOPULMONARY RESUSCITATION IN A SWINE MODEL OF VENTRICULAR FIBRILLATION
    Li Huiqing
    Wang Lixiang
    Liu Yahua
    Sun Kun
    Ma Lizhi
    Guo Xiaodong
    Li Xiuman
    HEART, 2011, 97 : A9 - A9
  • [22] Enhanced external counterpulsation improves cerebral blood flow following cardiopulmonary resuscitation
    Liu, Rong
    Liang, Zi-Jing
    Liao, Xiao-Xing
    Hu, Chun-Lin
    Jiang, Li
    Dai, Gang
    Li, Ying-Qing
    Wei, Hong-Yan
    Wu, Gui-Fu
    Li, Xin
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (12): : 1638 - 1645
  • [23] The potential of leg-foot chest compression as an alternative to conventional hands-on compression during cardiopulmonary resuscitation
    Takahashi, Yoshiaki
    Saitoh, Takeji
    Okada, Misaki
    Satoh, Hiroshi
    Akai, Toshiya
    Mochizuki, Toshiaki
    Hozumi, Hironao
    Saotome, Masao
    Urushida, Tsuyoshi
    Katoh, Hideki
    Hayashi, Hideharu
    Yoshino, Atsuto
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2019, 26 (02) : 106 - 110
  • [24] Elevation of the Head and Thorax During Cardiopulmonary Resuscitation Improves Cerebral Blood Flow in a Swine Model of Prolonged Cardiac Arrest
    Dodd, K. W.
    Moore, J. C.
    Segal, N.
    Lick, M. C.
    Salverda, B. J.
    Hinke, M. B.
    Robinson, A. E.
    Debaty, G.
    Lurie, K. G.
    ANNALS OF EMERGENCY MEDICINE, 2017, 70 (04) : S139 - S140
  • [25] CEREBRAL AND MYOCARDIAL BLOOD-FLOW RESPONSE TO INCREASING DOSES OF EPINEPHRINE DURING CARDIOPULMONARY-RESUSCITATION IN INFANT SWINE
    BERKOWITZ, ID
    KOEHLER, RC
    SCHLEIEN, CL
    KUBOS, K
    DEAN, JM
    MICHAEL, JR
    ROGERS, MC
    TRAYSTMAN, RJ
    PEDIATRIC RESEARCH, 1987, 21 (04) : A197 - A197
  • [26] The Maximum Diameter of the Left Ventricle May Not Be the Optimum Target for Chest Compression During Cardiopulmonary Resuscitation: A Preliminary, Observational Study Challenging the Traditional Assumption
    Park, Gwang-Yeol
    Oh, Won Sup
    Chon, Sung-Bin
    Kim, Shinwoo
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2020, 34 (02) : 383 - 391
  • [27] HEMODYNAMIC MODELING OF BLOOD-FLOW DURING CARDIOPULMONARY RESUSCITATION (CPR) USING SPICE
    TALLEY, DB
    ORNATO, JP
    CLARK, AM
    RITTGERS, SE
    CLINICAL RESEARCH, 1988, 36 (01): : A8 - A8
  • [28] A MODEL FOR REGIONAL BLOOD-FLOW MEASUREMENTS DURING CARDIOPULMONARY RESUSCITATION IN A SWINE MODEL
    TAYLOR, RB
    BROWN, CG
    BRIDGES, T
    WERMAN, HA
    ASHTON, J
    HAMLIN, RL
    RESUSCITATION, 1988, 16 (02) : 107 - 118
  • [29] Optimal landmark for chest compression during cardiopulmonary resuscitation derived from a chest computed tomography in arms-down position
    Usawasuraiin, P.
    Wittayachamnankul, B.
    Euathrongchit, J.
    Phinyo, P.
    Tangsuwanaruk, T.
    EUROPEAN HEART JOURNAL, 2022, 43
  • [30] Cardiac output, coronary blood flow, and blood gases during open-chest standard and compression-active-decompression cardiopulmonary resuscitation
    Engoren, M
    Severyn, F
    Fenn-Buderer, N
    DeFrank, M
    RESUSCITATION, 2002, 55 (03) : 309 - 316