Intercondylar eminence fracture treated by resorbable magnesium screws osteosynthesis: A case series

被引:36
|
作者
Gigante, A. [1 ]
Setaro, N. [1 ]
Rotini, M. [1 ]
Finzi, S. S. [1 ]
Marinelli, M. [2 ]
机构
[1] Univ Politecn Marche, Sch Med, Dept Clin & Mol Sci, Via Tronto 10-A, I-60126 Ancona, Italy
[2] Azienda Osped Univ, Osped Riuniti Ancona, Clin Adult & Paediat Orthopaed, Ancona, Italy
关键词
Knee; Tibia; Fracture; Intercondylar; Eminence; Avulsion; Magnesium; Resorbable; Screws; Osteosynthesis; TIBIAL SPINE FRACTURES; TERM-FOLLOW-UP; AVULSION FRACTURE; ARTHROSCOPIC FIXATION; CANNULATED SCREW; SUTURE FIXATION; BONE RESPONSE; CHILDREN; IMPLANTS; MANAGEMENT;
D O I
10.1016/j.injury.2018.09.055
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Tibial spine avulsion fractures are mostly a paediatric injury which appropriate treatment is currently debated in literature. The choice between conservative and surgical treatment is based on the radiographic classification of Meyers-McKeever. The most diffused surgical techniques involve either internal fixation devices (screws) or bone tunnels fixation with resorbable sutures. Today, a third option is represented by resorbable magnesium screws which could combine the best features of the two classical systems. Objective of this study is to investigate the efficacy of these new devices in the surgical treatment of tibial spine avulsions. Materials and methods: Since 2014 we have seen seven patients with tibial eminence fracture. Patients underwent clinical and radiological examination (MRI, CT scan) before surgery. Only 3 patients that presented with a grade III or IV lesion were treated surgically with internal fixation with magnesium resorbable screws. In post-operative follow-up, functional recovery was evaluated at 1, 2, 4, 6 and 12 months, clinically and by X-ray. Lysholm and IKDC scores were submitted at 1, 2, 6 and 12 months. MRI was repeated at 6 and 12 months. Results: All three surgical patients showed progressive clinical and functional improvement during the follow-up period. The first case showed a quicker overall recovery rate, which might be due to the lower grade of the lesion. Radiographs and MRI evaluation showed regular healing of the injury. The devices appeared completely resorbed at the 6 months follow-up and replaced by newly formed bone at the 12 months follow-up. Conclusions: The treatment of tibial spine avulsion fractures with arthroscopic reduction and internal fixation (ARIF) technique by magnesium resorbable screws seems to result in an excellent functional recovery without complications related to fixation devices, which were completely resorbed after 6 months and replaced by newly formed bone after 12 months. This new method could be considered as an alternative option to classic techniques by non resorbable fixation devices or bone tunnel fixation. Further studies are needed in order to evaluate the efficacy of these new devices in a wider group of patients. (C) 2018 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:S48 / S53
页数:6
相关论文
共 50 条
  • [21] Outcome of Minimally Invasive Osteosynthesis for Displaced Intra-articular Calcaneal Fractures Using Cannulated Screws: A Prospective Case Series
    Shams, Ahmed
    Gamal, Osama
    Mesregah, Mohamed Kamal
    JOURNAL OF FOOT & ANKLE SURGERY, 2021, 60 (01): : 55 - 60
  • [22] A Case of Distal Femur Medial Condyle Hoffa Type II(C) Fracture Treated with Headless Screws
    Kapoor, Chirag
    Merh, Aditya
    Shah, Malkesh
    Golwala, Paresh
    CUREUS, 2016, 8 (09):
  • [23] MRI evaluation of resorbable poly lactic-co-glycolic acid (PLGA) screws used in pelvic osteotomies in children—a retrospective case series
    Henrik Hedelin
    Hanna Hebelka
    Helena Brisby
    Tero Laine
    Journal of Orthopaedic Surgery and Research, 15
  • [24] Femoral Nerve Palsy After Pelvic Fracture Treated With INFIX: A Case Series
    Hesse, Daniel
    Kandmir, Utku
    Solberg, Brian
    Stroh, Alex
    Osgood, Greg
    Sems, Stephen A.
    Collinge, Cory A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (03) : 138 - 143
  • [25] MRI evaluation of resorbable poly lactic-co-glycolic acid (PLGA) screws used in pelvic osteotomies in children-a retrospective case series
    Hedelin, Henrik
    Hebelka, Hanna
    Brisby, Helena
    Laine, Tero
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [26] Trifocal Femoral Fracture Treated With an Intramedullary Nail Accompanied With Compression Bolts and Lag Screws: Case Presentation and Literature Review
    Papaioannou, Ioannis
    Baikousis, Andreas
    Korovessis, Panagiotis
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (05)
  • [27] Isolated Shear Fracture of the Metatarsal Head in Lesser Toes Treated With ORIF: Case Series
    Li, Ying
    Li, Wenjing
    Li, Shaoliang
    Wang, Yan
    Guan, Shengsheng
    Wu, Yong
    FOOT & ANKLE INTERNATIONAL, 2021, 42 (01) : 46 - 54
  • [28] Incomplete Atypical Femoral Fracture Treated by Prophylactic Intramedullary Nail Fixation: A Case Series
    Sakuda, Tomohiko
    Omoto, Osamu
    Hamasaki, Takahiko
    Okimoto, Nobukazu
    Adachi, Nobuo
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (02)
  • [29] Peri-articular elbow fracture fixations with magnesium implants and a review of current literature: A case series
    Fang, Christopher
    Premchand, Antony Xavier Rex
    Park, Derek Howard
    Toon, Dong Hao
    WORLD JOURNAL OF ORTHOPEDICS, 2024, 15 (03): : 215 - 229
  • [30] Comparison of intraarticular distal humerus fracture outcomes treated with or without olecranon osteotomy - A case series
    Baloch, Naveed
    Ahmad, Tashfeen
    Muhammad, Zehra Abdul
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2020, 70 (02) : S102 - S105