Intercondylar eminence fracture treated by resorbable magnesium screws osteosynthesis: A case series

被引:36
|
作者
Gigante, A. [1 ]
Setaro, N. [1 ]
Rotini, M. [1 ]
Finzi, S. S. [1 ]
Marinelli, M. [2 ]
机构
[1] Univ Politecn Marche, Sch Med, Dept Clin & Mol Sci, Via Tronto 10-A, I-60126 Ancona, Italy
[2] Azienda Osped Univ, Osped Riuniti Ancona, Clin Adult & Paediat Orthopaed, Ancona, Italy
关键词
Knee; Tibia; Fracture; Intercondylar; Eminence; Avulsion; Magnesium; Resorbable; Screws; Osteosynthesis; TIBIAL SPINE FRACTURES; TERM-FOLLOW-UP; AVULSION FRACTURE; ARTHROSCOPIC FIXATION; CANNULATED SCREW; SUTURE FIXATION; BONE RESPONSE; CHILDREN; IMPLANTS; MANAGEMENT;
D O I
10.1016/j.injury.2018.09.055
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Tibial spine avulsion fractures are mostly a paediatric injury which appropriate treatment is currently debated in literature. The choice between conservative and surgical treatment is based on the radiographic classification of Meyers-McKeever. The most diffused surgical techniques involve either internal fixation devices (screws) or bone tunnels fixation with resorbable sutures. Today, a third option is represented by resorbable magnesium screws which could combine the best features of the two classical systems. Objective of this study is to investigate the efficacy of these new devices in the surgical treatment of tibial spine avulsions. Materials and methods: Since 2014 we have seen seven patients with tibial eminence fracture. Patients underwent clinical and radiological examination (MRI, CT scan) before surgery. Only 3 patients that presented with a grade III or IV lesion were treated surgically with internal fixation with magnesium resorbable screws. In post-operative follow-up, functional recovery was evaluated at 1, 2, 4, 6 and 12 months, clinically and by X-ray. Lysholm and IKDC scores were submitted at 1, 2, 6 and 12 months. MRI was repeated at 6 and 12 months. Results: All three surgical patients showed progressive clinical and functional improvement during the follow-up period. The first case showed a quicker overall recovery rate, which might be due to the lower grade of the lesion. Radiographs and MRI evaluation showed regular healing of the injury. The devices appeared completely resorbed at the 6 months follow-up and replaced by newly formed bone at the 12 months follow-up. Conclusions: The treatment of tibial spine avulsion fractures with arthroscopic reduction and internal fixation (ARIF) technique by magnesium resorbable screws seems to result in an excellent functional recovery without complications related to fixation devices, which were completely resorbed after 6 months and replaced by newly formed bone after 12 months. This new method could be considered as an alternative option to classic techniques by non resorbable fixation devices or bone tunnel fixation. Further studies are needed in order to evaluate the efficacy of these new devices in a wider group of patients. (C) 2018 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:S48 / S53
页数:6
相关论文
共 50 条
  • [1] Fracture of the intercondylar eminence of the tibia treated by arthroscopic internal fixation
    Walmsley, JP
    EQUINE VETERINARY JOURNAL, 1997, 29 (02) : 148 - 150
  • [2] Surgical outcomes of scaphoid fracture osteosynthesis with magnesium screws
    Polat, Oktay
    Toy, Serdar
    Kibar, Birkan
    JOINT DISEASES AND RELATED SURGERY, 2021, 32 (03): : 721 - 728
  • [3] Biodegradable magnesium screws in elbow fracture fixation: Clinical case series
    Lam, Wai-Him
    Tso, Chi-Yin
    Tang, Ning
    Cheung, Wing-Hoi
    Qin, Ling
    Wong, Ronald Man-Yeung
    JOURNAL OF ORTHOPAEDICS TRAUMA AND REHABILITATION, 2022, 29 (02)
  • [4] Greenstick intercondylar fracture of the humerus - A case series
    Karmani, S
    Perry, A
    Calvert, P
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (06): : 539 - 540
  • [5] Osteosynthesis in intercondylar and femoral epiphysis fracture in dog: Description of a clinical case
    Angarita C, Yadira
    Molina R, Larry
    Maya M, Daniela
    REVISTA DE INVESTIGACIONES VETERINARIAS DEL PERU, 2020, 31 (02):
  • [6] Fracture of the intercondylar eminence of the tibia type II in children: 20 surgically-treated cases
    Louis, M. -L.
    Guillaume, J. -M.
    Toth, C.
    Launay, F.
    Jouve, J. -L.
    Bollini, G.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2007, 93 (01): : 56 - 62
  • [7] Fracture of the medial intercondylar eminence of the tibia in horses treated by arthroscopic fragment removal (21 horses)
    Rubio-Martinez, L. M.
    Redding, W. R.
    Bladon, B.
    Wilderjans, H.
    Payne, R. J.
    Tessier, C.
    Geffroy, O.
    Parker, R.
    Bell, C.
    Collingwood, F. A.
    EQUINE VETERINARY JOURNAL, 2018, 50 (01) : 60 - 64
  • [8] Resorbable magnesium metal membrane for sinus lift procedures: a case series
    Elad, Akiva
    Pul, Luka
    Rider, Patrick
    Rogge, Svenja
    Witte, Frank
    Tadic, Drazen
    Mijiritsky, Eitan
    Kacarevic, Zeljka Peric
    Steigmann, Larissa
    BMC ORAL HEALTH, 2023, 23 (01)
  • [9] Resorbable magnesium metal membrane for sinus lift procedures: a case series
    Akiva Elad
    Luka Pul
    Patrick Rider
    Svenja Rogge
    Frank Witte
    Dražen Tadić
    Eitan Mijiritsky
    Željka Perić Kačarević
    Larissa Steigmann
    BMC Oral Health, 23
  • [10] Miniplate osteosynthesis in fracture surgeries: Case series with review of concepts
    Yoon, Yong-Cheol
    Oh, Chang-Wug
    Lee, Dong-Whan
    Sim, Jae-Ang
    Oh, Jong-Keon
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (04): : 878 - 886