Influence of nonionic surfactants on the potentiometric response of hydrogen ion-selective polymeric membrane electrodes

被引:45
|
作者
EspadasTorre, C [1 ]
Bakker, E [1 ]
Barker, S [1 ]
Meyerhoff, ME [1 ]
机构
[1] UNIV MICHIGAN, DEPT CHEM, ANN ARBOR, MI 48109 USA
关键词
D O I
10.1021/ac951017g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The influence of poly(ethylene oxide)-based nonionic surfactants (i.e., Triton X-100 and Brij 35) in the sample phase on the response properties of hydrogen ion-selective polymeric membrane electrodes containing mobile (lipophilic amines) or covalently bound (aminated-poly(vinyl chloride)) hydrogen ion carriers is reported. In the presence of these nonionic surfactants, membrane electrode response toward interfering cation activity (e.g., Na+) in the sample phase is increased substantially and the pH measuring range shortened. The degree of cation interference for pH measurements is shown to correlate with the basicity of the hydrogen ion carrier doped within the membrane phase. The observed deterioration in selectivity arises from the partitioning of the surfactant into the membrane and concomitant extraction of metal cations by the surfactants in the organic phase. The effect of nonionic surfactants on pH electrodes prepared with aminated-PVC membranes is shown to be more complex, with additional large shifts in EMF values apparently arising from multidentate interactions between the surfactant molecules and the polymeric amine in the membrane, leading to a change in the apparent pK(a) values for the amine sites. The effects induced by nonionic surfactants on the EMF response function of hydrogen ion-selective polymeric membrane electrodes are modeled, and experimental results are shown to correlate well with theoretical predictions.
引用
收藏
页码:1623 / 1631
页数:9
相关论文
共 50 条
  • [31] ION-SELECTIVE ELECTRODES, POTENTIOMETRY, AND POTENTIOMETRIC TITRATIONS
    BUCK, RP
    ANALYTICAL CHEMISTRY, 1974, 46 (05) : R28 - R51
  • [32] Electrochemical sample matrix elimination for trace-level potentiometric detection with polymeric membrane ion-selective electrodes
    Chumbimuni-Torres, Karin Y.
    Calvo-Marzal, Percy
    Wang, Joseph
    Bakker, Eric
    ANALYTICAL CHEMISTRY, 2008, 80 (15) : 6114 - 6118
  • [33] POTENTIOMETRIC TITRATION OF PESTICIDES WITH ION-SELECTIVE ELECTRODES
    KIYANSKII, VV
    BURAKHTA, VA
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1990, 45 (02): : 266 - 270
  • [34] POTENTIOMETRIC DETERMINATION OF PENICILLINS WITH ION-SELECTIVE ELECTRODES
    YAO, SZ
    SHIAO, J
    NIE, LH
    TALANTA, 1989, 36 (12) : 1249 - 1252
  • [35] POTENTIOMETRIC TITRATION OF SILVER WITH ION-SELECTIVE ELECTRODES
    GEISSLER, M
    ANALYTICA CHIMICA ACTA, 1977, 90 (MAY) : 249 - 252
  • [36] DYNAMIC-RESPONSE OF ION-SELECTIVE MEMBRANE ELECTRODES
    RANGARAJAN, R
    RECHNITZ, GA
    ANALYTICAL CHEMISTRY, 1975, 47 (02) : 324 - 326
  • [37] POTENTIOMETRIC MICRODETERMINATION WITH ION-SELECTIVE REFERENCE ELECTRODES
    LEXA, J
    STULIK, K
    CHEMICKE LISTY, 1988, 82 (12): : 1287 - 1294
  • [38] DEFINITION OF THE RESPONSE-TIME OF ION-SELECTIVE ELECTRODES AND POTENTIOMETRIC CELLS
    LINDNER, E
    TOTH, K
    PUNGOR, E
    UMEZAWA, Y
    ANALYTICAL CHEMISTRY, 1984, 56 (04) : 808 - 810
  • [39] Pulsed Galvanostatic Control of a Polymeric Membrane Ion-Selective Electrode for Potentiometric Immunoassays
    Ding, Jiawang
    Wang, Xuewei
    Qin, Wei
    ACS APPLIED MATERIALS & INTERFACES, 2013, 5 (19) : 9488 - 9493
  • [40] MEMBRANE ION-SELECTIVE ELECTRODES FOR SEMIAUTOMATIC POTENTIOMETRIC ANALYSIS OF ELECTROLYTES IN PLATING BATHS
    KIYANSKII, VV
    AITYURINA, TG
    INDUSTRIAL LABORATORY, 1981, 47 (12): : 1211 - 1214