Effect of platelet additive solution on bacterial dynamics and their influence on platelet quality in stored platelet concentrates

被引:32
|
作者
Greco, Carey A.
Zhang, Jerry G.
Kalab, Miloslav
Yi, Qi-Long
Ramirez-Arcos, Sandra M. [1 ]
Gyongyossy-Issa, Maria I. C.
机构
[1] Canadian Blood Serv, Ottawa, ON K1G 4J5, Canada
关键词
BLOOD COMPONENTS; STORAGE; PLASMA; TRANSFUSION; CONTAMINATION; PAS; METABOLISM; PARAMETERS; REDUCTION; GROWTH;
D O I
10.1111/j.1537-2995.2010.02726.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Platelet additive solutions (PASs) are an alternative to plasma for the storage of platelet concentrates (PCs) However, little is known about the effect of PAS on the growth dynamics of contaminant bacteria Conversely, there have been no studies on the influence of bacteria on platelet (PLT) quality indicators when suspended in PAS. STUDY DESIGN AND METHODS: Eight bully coats were pooled, split, and processed into PCs suspended in either plasma or PAS (SSP+, MacoPharma) PCs were inoculated with 10 and 100 colony-forming units (CFUs)/bag of either Serratia liquefaciens or Staphylococcus epidermidis Bacterial growth was measured over 5 days by colony counts and bacterial biofilm formation was assayed by scanning electron microscopy and crystal violet staining Concurrently, PLT markers were measured by an assay panel and flow cytometry. RESULTS: S liquefaciens exhibited an apparent slower doubling time in plasma-suspended PCs (plasma-PCs). Biofilm formation by S. liquefaciens and S epidermidis was significantly greater in PCs stored in plasma than in PAS Although S. liquefaciens altered several PLT quality markers by Days 3 to 4 postinoculation in both PAS- and plasma-PCs, S epidermidis contamination did not produce measurable PLT changes. CONCLUSIONS: S liquefaciens can be detected more quickly in PAS-suspended PCs (PAS-PCs) than in plasma-PCs by colony counting. Furthermore, reduced biofilm formation by S liquefaciens and S. epidermidis during storage in PAS-PCs increases bacteria availability for sampling detection Culture-based detection remains the earliest indicator of bacterial presence in PAS-PCs, while changes of PLT quality can herald S liquefaciens contamination when in excess of 10(8) CFUs/mL.
引用
收藏
页码:2344 / 2352
页数:9
相关论文
共 50 条
  • [41] Quality assessment and transfusion efficacy of buffy coat-derived platelet concentrates washed with platelet additive solution
    Fernandez-Munoz, Hermogenes
    Castilla-Llorente, Cristina
    Plaza, Eva M.
    Martinez-Millan, Cristina
    Heras, Inmaculada
    Iniesta, Pastora
    Amigo, Maria L.
    Ferrer-Marin, Francisca
    Candela, Maria J.
    Lozano, Maria L.
    Vicente, Vicente
    Rivera, Jose
    [J]. BLOOD TRANSFUSION, 2018, 16 (03) : 273 - 278
  • [42] Flow cytometric analysis of platelet function in stored platelet concentrates
    Wang, C
    Mody, M
    Herst, R
    Sher, G
    Freedman, J
    [J]. TRANSFUSION SCIENCE, 1999, 20 (02): : 129 - 139
  • [43] Introduction of platelet additive solution in platelet concentrates: Towards a decrease of blood transfusion reactions
    Rebibo, D.
    Simonet, A.
    Hauser, L.
    [J]. TRANSFUSION CLINIQUE ET BIOLOGIQUE, 2008, 15 (05) : 289 - 293
  • [44] Are the BaCT/ALERT and PALL enhanced bacterial detection systems suitable for screening platelet additive solution (PAS) platelet concentrates?
    McDonald, C. P.
    Sapsford, J.
    Colvin, J.
    Biggs, C.
    Goodhand, K.
    [J]. VOX SANGUINIS, 2006, 91 : 94 - 94
  • [45] The effect of interruption of agitation on in vitro measures of platelet concentrates in additive solution
    van der Meer, Pieter F.
    Liefting, Lara A. E.
    Pietersz, Ruby N. I.
    [J]. TRANSFUSION, 2007, 47 (06) : 955 - 959
  • [46] BACTERIAL CONTAMINATION OF PLATELET CONCENTRATES STORED AT 20 DEGREES C
    CUNNINGHAM, M
    CASH, JD
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1973, 26 (06) : 401 - 404
  • [47] EFFECT OF AGITATION ON THE QUALITY OF PLATELET CONCENTRATES
    MITCHELL, SG
    HAWKER, RJ
    TURNER, VS
    HESSLEWOOD, SR
    HARDING, LK
    [J]. VOX SANGUINIS, 1994, 67 (02) : 160 - 165
  • [48] QUALITY OF PLATELET CONCENTRATES
    SWEENEY, JD
    HOLME, S
    HEATON, A
    [J]. IMMUNOLOGICAL INVESTIGATIONS, 1995, 24 (1-2) : 353 - 370
  • [49] Quality of platelet concentrates
    Flegel, WA
    [J]. TRANSFUSION, 1998, 38 (08) : 799 - 799
  • [50] QUALITY OF PLATELET CONCENTRATES
    Jaroonsirimaneekul, Th
    Phumiyoch, N.
    Paupairoj, C.
    Romphruk, A.
    [J]. VOX SANGUINIS, 2011, 101 : 70 - 70