Development and applications of solid-phase extraction and liquid chromatography-mass spectrometry methods for quantification of microcystins in urine, plasma, and serum

被引:29
|
作者
Palagama, Dilrukshika S. W. [1 ]
Baliu-Rodriguez, David [1 ]
Lad, Apurva [2 ]
Levison, Bruce S. [3 ]
Kennedy, David J. [2 ]
Hailer, Steven T. [2 ]
Westrick, Judy [4 ]
Hensley, Kenneth [5 ]
Isailovic, Dragan [1 ]
机构
[1] Univ Toledo, Coll Nat Sci & Math, Dept Chem & Biochem, Toledo, OH 43606 USA
[2] Univ Toledo, Med Ctr, Dept Med, Hlth Sci Campus, Toledo, OH 43614 USA
[3] Univ Toledo, Med Ctr, Dept Physiol & Pharmacol, Hlth Sci Campus, Toledo, OH 43614 USA
[4] Wayne State Univ, Coll Liberal Arts & Sci, Dept Chem, Detroit, MI 48202 USA
[5] Arkansas Coll Osteopath Med, Dept Biochem Cellular & Mol Biol, Ft Smith, AR 72916 USA
关键词
Solid-phase extraction; Biofluids; Microcystins; Quantification; LC-MS; MS/MS; BLUE-GREEN-ALGA; CYANOBACTERIAL TOXINS; BIOLOGICAL EVIDENCE; EXPOSURE; WATER; LR; EXCRETION; TOXICITY; LIVER; PEPTIDE;
D O I
10.1016/j.chroma.2018.08.023
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The protocols for solid-phase extraction (SPE) of six microcystins (MCs; MC-LR, MC-RR, MC-LA, MC-LF, MC-LW, and MC-YR) from mouse urine, mouse plasma, and human serum are reported. The quantification of those MCs in biofluids was achieved using HPLC-orbitrap-MS in selected-ion monitoring (SIM) mode, and MCs in urine samples were also quantified by ultra-HPLC-triple quadrupole-tandem mass spectrometry (UHPLC-QqQ-MS/MS) in multiple reaction monitoring (MRM) mode. Under optimal conditions, the extraction recoveries of MCs from samples spiked at two different concentrations (1 mu g/L and 10 mu g/L) ranged from 90.4% to 104.3% with relative standard deviations (RSDs) <= 4.7% for mouse urine, 90.4-106.9% with RSDs <= 6.3% for mouse plasma, and 90.0-104.8% with RSDs <= 5.0% for human serum. Matrix-matched internal standard calibration curves were linear with R-2 >= 0.9950 for MC-LR, MC-RR and MC-YR, and R-2 >= 0.9883 for MC-LA, MC-LF, and MC-LW. The limits of quantification (LOQs) in spiked urine samples were similar to 0.13 mu g/L for MC-LR, MC-RR, and MC-YR, and similar to 0.50 mu g/L for MC-LA, MC-LF, and MC-LW, while the LOQs in spiked plasma and serum were similar to 0.25 mu g/L for MC-LR, MC-RR, and MC-YR, and similar to 1.00 mu g/L for MC-LA, MC-LF, and MC-LW. The developed methods were applied in a proof-of-concept study to quantify urinary and blood concentrations of MC-LR after oral administration to mice. The urine of mice administered 50 mu g of MC-LR per kg bodyweight contained on average 1.30 mu g/L of MC-LR (n = 8), while mice administered 100 mu g of MC-LR per kg bodyweight had average MC-LR concentration of 2.82 mu g/L (n = 8). MC-LR was also quantified in the plasma of the same mice. The results showed that increased MC-LR dosage led to larger urinary and plasma MC-LR concentrations and the developed methods were effective for the quantification of MCs in mouse biofluids. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:66 / 77
页数:12
相关论文
共 50 条
  • [31] Determination of quaternary ammonium compounds in seawater samples by solid-phase extraction and liquid chromatography-mass spectrometry
    Bassarab, P.
    Williams, D.
    Dean, J. R.
    Ludkin, E.
    Perry, J. J.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (05) : 673 - 677
  • [32] Enhanced methods for conditioning, storage, and extraction of liquid and solid samples of manure for determination of steroid hormones by solid-phase extraction and gas chromatography-mass spectrometry
    Combalbert, Sarah
    Pype, Marie-Laure
    Bernet, Nicolas
    Hernandez-Raquet, Guillermina
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (02) : 973 - 984
  • [33] Simultaneous determination of four opioids in urine by solid-phase extraction and derivatization coupled with gas chromatography-mass spectrometry
    Gao Hang
    Liu Yaxun
    Ke Wei
    Liu Kai
    Ni Liuyang
    Tao Tao
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2020, 38 (11) : 1348 - 1354
  • [34] Pipette tip solid-phase extraction and gas chromatography-mass spectrometry for the determination of mequitazine in human plasma
    Kumazawa, Takeshi
    Hasegawa, Chika
    Lee, Xiao-Pen
    Marumo, Akemi
    Shimmen, Natsuko
    Ishii, Akira
    Seno, Hiroshi
    Sato, Keizo
    [J]. TALANTA, 2006, 70 (02) : 474 - 478
  • [35] Quantification of free and esterified sterols in Portuguese olive oils by solid-phase extraction and gas chromatography-mass spectrometry
    Cunha, Sara S.
    Fernandes, Jose O.
    Oliveira, M. Beatriz P. P.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1128 (1-2) : 220 - 227
  • [36] Validated Method for the Quantification of Baclofen in Human Plasma Using Solid-Phase Extraction and Liquid Chromatography-Tandem Mass Spectrometry
    Nahar, Limon Khatun
    Cordero, Rosa Elena
    Nutt, David
    Lingford-Hughes, Anne
    Turton, Samuel
    Durant, Claire
    Wilson, Sue
    Paterson, Sue
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2016, 40 (02) : 117 - 123
  • [37] Quantification of trandolapril and its metabolite trandolaprilat in human plasma by liquid chromatography/tandem mass spectrometry using solid-phase extraction
    Nirogi, Ramakrishna V. S.
    Kandikere, Vishwottam N.
    Shrivastava, Wishu
    Mudigonda, Koteshwara
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (24) : 3709 - 3716
  • [38] Synthesis of a magnetic covalent organic framework as sorbents for solid-phase extraction of aflatoxins in food prior to quantification by liquid chromatography-mass spectrometry
    Li, Jie
    Xu, Xiuli
    Guo, Wei
    Zhang, Yuan
    Feng, Xuesong
    Zhang, Feng
    [J]. FOOD CHEMISTRY, 2022, 387
  • [39] Quantification of dissolved metabolites in environmental samples through cation-exchange solid-phase extraction paired with liquid chromatography-mass spectrometry
    Sacks, Joshua S.
    Heal, Katherine R.
    Boysen, Angela K.
    Carlson, Laura T.
    Ingalls, Anitra E.
    [J]. LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2022, 20 (11): : 683 - 700
  • [40] Determination of cocaine and cocaethylene in urine by solid-phase microextraction and gas chromatography-mass spectrometry
    Yonamine, Mauricio
    Saviano, Alessandro Morais
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (10) : 1071 - 1075