The Difference in Intraocular Pressure before and after Visual Field Test Measured by Rebound Tonometer

被引:0
|
作者
Park, Joong Hyun [1 ]
Kim, Jin Young [1 ]
Lee, Eun Kyoung [2 ]
Lee, Hye Jin [1 ]
Jeong, Jin Ho [1 ]
Lee, Sang-Yoon [1 ]
机构
[1] Jeju Natl Univ, Sch Med, Jeju Natl Univ Hosp, Dept Ophthalmol, Jeju, South Korea
[2] Seoul Natl Univ, Coll Med, Seoul Natl Univ Hosp, Dept Ophthalmol, Seoul, South Korea
来源
关键词
Intraocular pressure; Normal tension glaucoma; Rebound tonometer; Visual field test; GOLDMANN APPLANATION TONOMETER; OPEN-ANGLE GLAUCOMA; ICARE;
D O I
10.3341/jkos.2020.61.1.78
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the effect of a visual field (VF) test on intraocular pressure (IOP) and relevant parameters in a normal group and an open-angle glaucoma group, and to determine the appropriate time of IOP measurements. Methods: The IOP was measured by a rebound tonometer before and after a VF test for the normal, normal-tension glaucoma, and high-tension glaucoma groups, and IOP differences after the VF tests were compared among groups. Parameters including age, sex, axial length, central corneal thickness, IOP before the VF test, the VF index, mean deviation, VF test duration, and usage of IOP lowering medications were investigated, and the correlations of these parameters with IOP changes after VF tests were determined using linear regression analyses. Results: A total of 232 participants (232 eyes) included 55 normal subjects, 131 normal-tension glaucoma patients, and 46 high-tension glaucoma patients. The IOP differences after VF tests were not statistically significant in the normal and high-tension glaucoma groups, and the difference was 0.31 mmHg in the normal-tension glaucoma group (p = 0.013). Multivariate regression analyses revealed that axial length (p = 0.005) and IOP before the VF test (p < 0.001) were relevant factors in the total number of patients, and the axial length (p = 0.017), IOP before the VF test (p = 0.001), and duration (p = 0.029) were found to be significantly associated with IOP differences in the normal-tension glaucoma group. Conclusions: The IOP changes after VF tests using the rebound tonometer were significant in the normal-tension glaucoma group, but were within an acceptable range. The IOP value measured after a VF test is clinically valid in clinical practice.
引用
收藏
页码:78 / 85
页数:8
相关论文
共 50 条
  • [1] Central and peripheral intraocular pressure measured by a rebound tonometer
    Yamashita, Tsutomu
    Miki, Atsushi
    Ieki, Yoshiaki
    Kiryu, Junichi
    Yaoeda, Kiyoshi
    Shirakashi, Motohiro
    [J]. CLINICAL OPHTHALMOLOGY, 2011, 5 : 1113 - 1118
  • [2] Evaluation of the Effect of Body Position on Intraocular Pressure Measured with Rebound Tonometer
    Mayali, Huseyin
    Tekin, Beyza
    Kayikcioglu, Ozcan Rasim
    Kurt, Emin
    Ilker, Suleyman Sami
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2019, 49 (01): : 6 - 9
  • [3] Evaluation of intraocular pressure measurements obtained by use of a rebound tonometer and applanation tonometer in dogs before and after elective phacoemulsification
    Thompson-Hom, Amy L.
    Gerding, Paul A., Jr.
    [J]. AMERICAN JOURNAL OF VETERINARY RESEARCH, 2012, 73 (05) : 709 - 713
  • [4] Effect of Body Position on Intraocular Pressure Measured by Rebound Tonometer in Healthy Children
    Uzlu, Dilek
    Akyol, Nurettin
    Turk, Adem
    Gursoy, Nurcan
    Somuncu, Ahmet Mehmet
    Oruc, Yavuz
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2020, 50 (05): : 271 - 274
  • [5] Rebound Tonometer: Ideal Tonometer for Measurement of Accurate Intraocular Pressure
    Suman, Suwarna
    Agrawal, Ajai
    Pal, Virendra K.
    Pratap, Vir B.
    [J]. JOURNAL OF GLAUCOMA, 2014, 23 (09) : 633 - 637
  • [6] Evaluation of monkey intraocular pressure by rebound tonometer
    Yu, Wenhan
    Cao, Guiqun
    Qiu, Jinghua
    Liu, Xuyang
    Ma, Jia
    Li, Ni
    Yu, Man
    Yan, Naihong
    Chen, Lei
    Pang, Iok-Hou
    [J]. MOLECULAR VISION, 2009, 15 (235-36): : 2196 - 2201
  • [7] Intraocular pressure before and after visual field examination
    L Martin
    [J]. Eye, 2007, 21 : 1479 - 1481
  • [8] Intraocular pressure before and after visual field examination
    Martin, L.
    [J]. EYE, 2007, 21 (12) : 1479 - 1481
  • [9] Fluctuation of Intraocular Pressure with Noncontact Tonometer and Rebound Tonometer in the Normal Volunteers
    Tatara, Shunya
    Maeda, Fumiatsu
    Tsukahara, Yoshinosuke
    Yaoeda, Kiyoshi
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [10] Intraocular pressure variation by pneumatic tonometer before and after phacoemulsification
    Rodrigues, Francisco W.
    Silva, Camilla de M. N.
    Modesto, Deborah C.
    de Oliveira, Antonio W. S.
    da Silva, Rodrigo Egidio
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (04) : 393 - 397