Evaluation of the Effect of Body Position on Intraocular Pressure Measured with Rebound Tonometer

被引:11
|
作者
Mayali, Huseyin [1 ]
Tekin, Beyza [1 ]
Kayikcioglu, Ozcan Rasim [1 ]
Kurt, Emin [1 ]
Ilker, Suleyman Sami [1 ]
机构
[1] Manisa Celal Bayar Univ, Fac Med, Dept Ophthalmol, Manisa, Turkey
关键词
Intraocular pressure; body position; tonometer; EPISCLERAL VENOUS-PRESSURE; CENTRAL CORNEAL THICKNESS; POSTURAL RESPONSE; HEALTHY-SUBJECTS; GLAUCOMA; PATTERN; HEAD;
D O I
10.4274/tjo.galenos.2018.90359
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: It is important to determine variables that influence intraocular pressure (IOP) measurement. This study aimed to evaluate the effect of body position on IOP. Materials and Methods: The study included 52 right eyes of 52 patients who presented to the ophthalmology department of our hospital and had no ocular disease except refractive errors. IOP was measured with an Icare PRO tonometer while patients were in sitting, standing, and supine positions, with intervals of 10 minutes between the positions. Correlations between the results were evaluated using Spearman's correlation analysis and Wilcoxon tests. Results: Thirty-six of the 52 patients were female, 16 were male. Mean age was 31.65 +/- 6.30 (23-47) years. Mean IOP values in the sitting, standing, and lying positions were 17.76 +/- 3.41 (12.70-25.60) mmHg, 17.10 +/- 3.27 (11.50-25.20) mmHg, and 18.46 +/- 4.67 (10.50-29.40) mmHg, respectively. There were no statistically significant differences between measurements taken in the different positions (p=0.112, p=0.472, p=0.071). We observed that there was no relationship between age and body position (p>0.45, p>0.79, p>0.77) or between gender and position (p>0.59, p>0.69, p>0.54). Conclusion: Gender and age had no effect on IOP measured in different body positions. There were also no significant differences between IOP values measured in the different positions. Therefore, we believe the portable Icare PRO tonometer can be used for patients who are confined to bed and will provide IOP measurements that are concordant with values obtained while sitting.
引用
收藏
页码:6 / 9
页数:4
相关论文
共 50 条
  • [1] Effect of Body Position on Intraocular Pressure Measured by Rebound Tonometer in Healthy Children
    Uzlu, Dilek
    Akyol, Nurettin
    Turk, Adem
    Gursoy, Nurcan
    Somuncu, Ahmet Mehmet
    Oruc, Yavuz
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2020, 50 (05): : 271 - 274
  • [2] Evaluation of Rebound Tonometer for Measuring Intraocular Pressure at Deviated Angle and Position
    Takenaka, Joji
    Mochizuki, Hideki
    Kunihara, Eriko
    Tanaka, Junko
    Kiuchi, Yoshiaki
    [J]. CURRENT EYE RESEARCH, 2011, 36 (05) : 422 - 428
  • [3] Central and peripheral intraocular pressure measured by a rebound tonometer
    Yamashita, Tsutomu
    Miki, Atsushi
    Ieki, Yoshiaki
    Kiryu, Junichi
    Yaoeda, Kiyoshi
    Shirakashi, Motohiro
    [J]. CLINICAL OPHTHALMOLOGY, 2011, 5 : 1113 - 1118
  • [4] Intraocular Pressure Measurements in Standing Position with a Rebound Tonometer
    De Bernardo, Maddalena
    Borrelli, Maria
    Cembalo, Giovanni
    Rosa, Nicola
    [J]. MEDICINA-LITHUANIA, 2019, 55 (10):
  • [5] Evaluation of monkey intraocular pressure by rebound tonometer
    Yu, Wenhan
    Cao, Guiqun
    Qiu, Jinghua
    Liu, Xuyang
    Ma, Jia
    Li, Ni
    Yu, Man
    Yan, Naihong
    Chen, Lei
    Pang, Iok-Hou
    [J]. MOLECULAR VISION, 2009, 15 (235-36): : 2196 - 2201
  • [6] The influence of the tonometer position on canine intraocular pressure measurements using the Tonovet (R) rebound tonometer
    de Oliveira, Juliana Kravetz
    Montiani-Ferreira, Fabiano
    Williams, David L.
    [J]. OPEN VETERINARY JOURNAL, 2018, 8 (01) : 68 - 76
  • [7] Evaluation of a rebound tonometer for measuring intraocular pressure in dogs and horses
    Knollinger, AM
    La Croix, NC
    Barrett, PM
    Miller, PE
    [J]. JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2005, 227 (02): : 244 - 248
  • [8] Rebound Tonometer: Ideal Tonometer for Measurement of Accurate Intraocular Pressure
    Suman, Suwarna
    Agrawal, Ajai
    Pal, Virendra K.
    Pratap, Vir B.
    [J]. JOURNAL OF GLAUCOMA, 2014, 23 (09) : 633 - 637
  • [9] Evaluation of the ICare Rebound Tonometer as a Home Intraocular Pressure Monitoring Device
    Asrani, Sanjay
    Chatterjee, Ashmita
    Wallace, David K.
    Santiago-Turla, Cecilia
    Stinnett, Sandra
    [J]. JOURNAL OF GLAUCOMA, 2011, 20 (02) : 74 - 79
  • [10] Evaluation of intraocular pressure estimates obtained using an iCare rebound tonometer
    Khanal, Safal
    Walton, Meredith
    Davey, Pinakin Gunvant
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2017, 100 (02) : 179 - 183