Estimation of intra-abdominal pressure by bladder pressure measurement: Validity and methodology

被引:135
|
作者
Fusco, MA
Martin, RS
Chang, MC
机构
[1] Wake Forest Univ, Bowman Gray Sch Med, Dept Gen Surg, Winston Salem, NC 27157 USA
[2] Melbourne Internal Med Associates, Melbourne, FL USA
关键词
bladder pressure; intra-abdominal pressure; abdominal compartment syndrome; intra-abdominal hypertension; abdominal decompression; urinary catheterization; manometry; bladder volume; monitoring techniques;
D O I
10.1097/00005373-200102000-00016
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Increased intra-abdominal pressure (IAP) is an adverse complication seen in critically ill, injured, and postoperative patients. IAP is estimated via the measurement of bladder pressure. Few studies have been performed to establish the actual relationship between IAP and bladder pressure. The purpose of this study was to confirm the association between intravesicular pressure and IAP and to determine the bladder volume that best approximates IAP, Methods: Thirty-seven patients undergoing laparoscopy had intravesicular pressures measured with bladder volumes of 0, 50, 100, 150, and 200 mi, at directly measured intra-abdominal pressures of 0, 5, 10, 15, 20, and 25 mm Hg, Correlation coefficients and differences were then determined. Results: Across the IAP range of 0 to 25 mm tig using all of the tested bladder volumes, the difference between IAP and intravesicular pressures (bias) was -3.8 +/- 0.29 mm Hg (95% confidence interval) and measurements were well correlated (R-2 = 0.68), Assessing all IAPs tested, a bladder volume of 0 mt demonstrated the lowest bias (-0.79 +/- 0.73 mm Hg). When considering only elevated IAPs (25 mm tig), a bladder volume of 50 mt revealed the lowest bias (-1.5 +/- 1.36 mm Hg), A bladder volume of 50 mt in patients with elevated IAP resulted in an intravesicular pressure 1 to 3 mm Hg higher than IAP (95% confidence interval). Conclusion: Intravesicular pressure closely approximates IAP, Instillation of 50 mt of liquid into the bladder improves the accuracy of the intravesicular pressure in measuring elevated IAPs.
引用
收藏
页码:297 / 302
页数:6
相关论文
共 50 条
  • [21] INTRA-ABDOMINAL PRESSURE
    ASPDEN, R
    [J]. CLINICAL BIOMECHANICS, 1988, 3 (01) : 48 - 48
  • [22] Estimating optimal bladder volume for intra-abdominal pressure measurement by bladder PV-curves
    Malbrain, MLNG
    Deeren, D
    Darquennes, K
    Van Mieghem, N
    Verbrugghe, W
    Daelemans, R
    Lins, R
    [J]. INTENSIVE CARE MEDICINE, 2003, 29 : S147 - S147
  • [23] Assessment of Intra-Abdominal Pressure by Measurement of Abdominal Wall Tension
    Havens, Joaquim M.
    Soybel, David I.
    [J]. JOURNAL OF SURGICAL RESEARCH, 2011, 166 (01) : 70 - 72
  • [24] Correlation between bladder pressure and intra-abdominal pressure in relation to respiratory pressures
    Mahler, C
    Kloosterziel, P
    Eshuis, J
    Weverling, G
    Bemelman, W
    Boermeester, M
    [J]. SHOCK, 2004, 21 : 110 - 110
  • [25] Effect of abdominal negative-pressure wound therapy on the measurement of intra-abdominal pressure
    Federico Garcia, Alberto
    Ignacio Sanchez, Alvaro
    Jose Gutierrez, Alvaro
    Gabriel Bayona, Juan
    Paula Naranjo, Maria
    Lago, Sebastian
    Carlos Puyana, Juan
    [J]. JOURNAL OF SURGICAL RESEARCH, 2018, 227 : 112 - 118
  • [26] New technique of direct intra-abdominal pressure measurement
    Risin, Elena
    Kessel, Boris
    Lieberman, Noah
    Schmilovich, Michael
    Ashkenazi, Itamar
    Alfici, Ricardo
    [J]. ASIAN JOURNAL OF SURGERY, 2006, 29 (04) : 247 - 250
  • [27] The Measurement of Intra-abdominal Pressure in Awake Rat Cystometry
    Kim, Khae Hawn
    [J]. INTERNATIONAL NEUROUROLOGY JOURNAL, 2013, 17 (02) : 43 - 43
  • [28] A user's guide to intra-abdominal pressure measurement
    Sugrue, Michael
    De Waele, Jan J.
    De Keulenaer, Bart L.
    Roberts, Derek J.
    Malbrain, Manu L. N. G.
    [J]. ANAESTHESIOLOGY INTENSIVE THERAPY, 2015, 47 (03) : 241 - 251
  • [30] Direct measurement of intra-abdominal pressure with a solid microtranducer
    Pracca F.F.
    Biestro A.A.
    Moraes L.
    Puppo C.B.
    Calvo S.M.
    Gorrasi J.
    Cancela M.
    [J]. Journal of Clinical Monitoring and Computing, 2007, 21 (3) : 167 - 170