摘要
Since the development of the first Point-of-care Testing device (POCT) in 1962, POCTs have found their way into nearly every facet of laboratory diagnostics due to their rapid turn-around-times, testing convenience, ease of use, and relatively lower costs. This review provides an update on the progress in the development of POCTs for TSH assays while highlighting the challenges of these methods and suggesting ways of overcoming them. To achieve this, a literature search of the appropriate databases (Google Scholar, MEDLINE, Science Direct, and PubMed) was conducted using the keywords: POCT, TSH, hyperthyroidism, and hypothyroidism. Relevant articles were identified, duplicates eliminated, then critically analyzed, and discussed in terms of their relevance to the research questions. The different sensitivities of the POCTs reported in the scientific literature are traceable to the peculiarities of the detection technique adopted and the sensitivity of the immune complex recognition, i.e., labelled versus unlabeled immunoassay methods. The main factors limiting the wide acceptance of POCTs are concerns over their clinical usefulness, accuracy, and data (in)security. Routine assessment of the technical competence of POCT operators and regular quality checks of the performance of these devices are critical to maintaining the clinical usefulness of POCTs in TSH measurement. Finally, further research is required to understand the dynamic expectations of clinicians regarding POCT use in diagnosing thyroid dysfunction especially in low- and middle-income countries where data on this subject is lacking.
引用
收藏
页码:8 / 14
页数:7
相关论文
共 46 条
  • [31] Automated pipette failure monitoring using image processing for point-of-care testing devices
    Chan-Young Park
    Jun Yeon
    Hye-Jeong Song
    Yu-Seop Kim
    Ki-Bong Nahm
    Jong-Dae Kim
    BioMedical Engineering OnLine, 17
  • [32] Electrochemical immunoassay for one-pot detection of thyroxin (T4) and thyroid-stimulating hormone (TSH) using magnetic and Janus nanoparticles
    Karami, Pari
    Gholamin, Danial
    Johari-Ahar, Mohammad
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (19) : 4741 - 4751
  • [33] Immunoradiometric assay for the in-vitro determination of thyroid stimulating hormone in human serum and plasma using solid phase anti-TSH cellulose particles
    N. L. Mehany
    M. T. El Kolaly
    S. M. Ayyoub
    S. E. M. Hassan
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 265 : 61 - 71
  • [34] Immunoradiometric assay for the in-vitro determination of thyroid stimulating hormone in human serum and plasma using solid phase anti-TSH cellulose particles
    Mehany, NL
    El Kolaly, MT
    Ayyoub, SM
    Hassan, SEM
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 265 (01) : 61 - 71
  • [35] Electrochemical immunoassay for one-pot detection of thyroxin (T4) and thyroid-stimulating hormone (TSH) using magnetic and Janus nanoparticles
    Pari Karami
    Danial Gholamin
    Mohammad Johari-Ahar
    Analytical and Bioanalytical Chemistry, 2023, 415 : 4741 - 4751
  • [36] Continuous quality improvement for point-of-care testing using background monitoring of duplicate specimens
    Kilgore, ML
    Steindel, SJ
    Smith, JA
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 1999, 123 (09) : 824 - 828
  • [37] Introduction of the Mobile Health Check System to Home Health Care Using Point-of-Care Testing Devices in Japan
    Sakamoto, Hideo
    Hata, Kiyomi
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2012, 138 : A193 - A193
  • [38] Prevalence of elevated thyroid stimulating hormone (TSH) levels using the conventional cut-off of 4.0 uIU/mL versus 3.0 uIU/mL.
    Sproul, K.
    Buyalos, R. P.
    Hubert, G. D.
    Kumar, A.
    FERTILITY AND STERILITY, 2007, 87 : S18 - S18
  • [39] Evaluation of Microvalves Developed for Point-of-Care Testing Devices Using Shape-Memory Polymers
    Jiang, Chenyang
    Takehara, Hiroaki
    Uto, Koichiro
    Ebara, Mitsuhiro
    Aoyagi, Takao
    Ichiki, Takanori
    JOURNAL OF PHOTOPOLYMER SCIENCE AND TECHNOLOGY, 2013, 26 (05) : 581 - 585
  • [40] A FOLLOW-UP-STUDY OF 85 PATIENTS WITH GRAVES-DISEASE IN REMISSION WHO DEVELOPED UNDETECTABLE SERUM THYROID-STIMULATING HORMONE CONCENTRATIONS USING SENSITIVE TSH ASSAYS
    NAGAI, K
    TAMAI, H
    MUKUTA, T
    MORITA, T
    MATSUBAYASHI, S
    KUMA, K
    NAKAGAWA, T
    HORMONE RESEARCH, 1991, 35 (05) : 185 - 189