Design and manufacture of the carrier and flex cable for the Leonardo 1K

被引:0
|
作者
Vaccarella, A. [1 ]
Herrald, N. [1 ]
Sharp, R. [1 ]
Gilbert, J. [1 ]
Ellis, M. [1 ]
Zemaityte, E. [2 ]
Hicks, M. [2 ]
机构
[1] Australian Natl Univ, Mt Stromlo Observ, Weston, ACT 2611, Australia
[2] Leonardo, First Ave, Southampton SO15 0LG, Hants, England
关键词
Avalanche photodiode; infra red; LmAPD; thermal analysis;
D O I
10.1117/12.2629916
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Leonardo partnered with the Institute for Astronomy (IfA), University of Hawaii to develop a 1K x 1K infrared avalanche photo diode suitable for low background science applications. Presented here is the design and thermal modeling for the Kovar carrier for mounting the detector as well as the challenges faced in designing and manufacturing the complex flex cable. The flex cable provides the 68 bond pads necessary to service the detector in a width of just over 17mm as well as providing filtering for the bias supplies. The final package is a compact, three side buttable package that has been successfully tested at an operating temperature of 80K.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Key design criteria for high-flex cable constructions
    Levesque, Mike
    Long, Dale S.
    Crouch, Ron
    Electronic Products, 2012, 54 (06):
  • [22] Immersing the human in the design: Design-for-manufacture of cable harnesses
    Simmons, JEL
    Ritchie, JM
    Holt, POB
    Russell, GT
    6TH WORLD MULTICONFERENCE ON SYSTEMICS, CYBERNETICS AND INFORMATICS, VOL XII, PROCEEDINGS: INDUSTRIAL SYSTEMS AND ENGINEERING II, 2002, : 75 - 79
  • [23] Accuracy of digital imaging interpretation on an 1K x 1K PC-based workstation in the emergency department
    Spigos D.G.
    Tzalonikou M.T.
    Bennett W.F.
    Mueller C.F.
    Terrell J.
    Emergency Radiology, 1999, 6 (5) : 272 - 275
  • [24] 基于1K×1K的多通道综合图像信号处理系统设计
    雷宏
    沈龙龙
    白江坡
    光电技术应用, 2020, 35 (03) : 26 - 30
  • [25] A new 1K*1K frame transfer CCD camera for high speed, high fidelity, digital imaging
    Litwiller, DJ
    SOLID STATE SENSOR ARRAYS: DEVELOPMENT AND APPLICATIONS, 1997, 3019 : 210 - 220
  • [26] A 1K SHADOW RAM FOR CIRCUMVENTION APPLICATIONS
    MURRAY, JR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (06) : 1403 - 1409
  • [27] 1K DELAY-LINE DIGITIZER
    NUNNALLY, C
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) : 722 - 729
  • [29] ON THE DIOPHANTINE EQUATION Σj=1k jPjp = Pnq
    Tchammou, E.
    Togbe, A.
    ACTA MATHEMATICA HUNGARICA, 2020, 162 (02) : 647 - 676
  • [30] NMR-SPECTRA AND RELAXATION BELOW 1K
    WAUGH, JS
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 195 : 1 - PHYS