Technical note: evaluation of dosimetric performance in a commercial 3D treatment planning system

被引:4
|
作者
Sandilos, P [1 ]
Seferlis, S [1 ]
Antypas, C [1 ]
Karaiskos, P [1 ]
Dardoufas, C [1 ]
Vlahos, L [1 ]
机构
[1] Univ Athens, Areteion Hosp, Med Sch, Dept Radiol, Athens 11528, Greece
来源
BRITISH JOURNAL OF RADIOLOGY | 2005年 / 78卷 / 934期
关键词
D O I
10.1259/bjr/57562962
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this work was to evaluate the dosimetric performance of a commercial treatment planning system (TPS) which employs a three-dimensional calculation algorithm (Nucletron Plato version 2.2.3), following the guidelines of the AAPM Task Group 23 (TG23). Seven test cases were used to test the TPS dosimetric performance in homogeneous water. These cases involved absolute dose measurements on central as well as off-axis points situated at various depths, using simple field arrangements, and comparison with corresponding TPS calculations. This comparison yielded differences within +/- 2% at all points, for all test cases. To test the ability of the TPS to account for tissue inhomogeneities, corresponding comparisons were performed with the presence of a low-density material in the beam to resemble an air inhomogeneity. Absolute dose measurements and corresponding TPS calculations showed a mean deviation of the order of +/- 3.5%, reaching a maximum of 11.5% for small field sizes (5 cm x 5 cm). In summary, observed deviations are well within the set tolerance levels while comparison with previous TPS versions showed that Plato version 2.2.3 is significantly improved, especially in dose calculations in the presence of low density inhomogeneities.
引用
收藏
页码:899 / 905
页数:7
相关论文
共 50 条
  • [21] Dosimetric evaluation of a three-dimensional treatment planning system
    Murugan, Appasamy
    Valas, Xavier Sidonia
    Thayalan, Kuppusamy
    Ramasubramanian, Velayudham
    [J]. JOURNAL OF MEDICAL PHYSICS, 2011, 36 (01) : 15 - 21
  • [22] Dosimetric evaluation of the clinical implementation of the first commercial IMRT Monte Carlo treatment planning system at 6 MV
    Heath, E
    Seuntjens, J
    Sheikh-Bagheri, D
    [J]. MEDICAL PHYSICS, 2004, 31 (10) : 2771 - 2779
  • [23] Evaluation system for 3d vr factory planning systems
    Integration von hard-und software für die digitale fabrikplanung: Bewertungssystem für 3d-vr-fabrikplanungssysteme
    [J]. Augustin, Harald (harald.augustin@reutlingen-university.de), 1600, VDI Fachmedien GmBH & Co. KG (111): : 591 - 596
  • [24] A new system for 3D planning of orthodontic treatment and 3D tooth movement simulation
    Alcañiz, M
    Chinesta, F
    Albalat, S
    Grau, V
    Monserrat, C
    [J]. COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, : 645 - 654
  • [25] 3D analytical dosimetric model for radiation treatment planning with the HDR Leipzig surface applicator
    Hsi, W
    Niu, H
    Chu, J
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1808 - 1808
  • [26] DOSIMETRIC EVALUATION OF A 3D DOSIMETER FOR HELICAL TOMOTHERAPY
    Paiusco, M.
    Errico, V. D.
    Cagni, E.
    Botti, A.
    Lambertini, D.
    Scotti, L.
    Gianlornbardo, A.
    Iori, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S552 - S552
  • [27] Methodology for commissioning a brachytherapy treatment planning system in the era of 3D planning
    Dempsey, Claire
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2010, 33 (04) : 373 - 373
  • [28] Methodology for commissioning a brachytherapy treatment planning system in the era of 3D planning
    Claire Dempsey
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2010, 33 : 341 - 349
  • [29] 3D CT simulation and treatment planning system for radiotherapy
    Yang, YL
    Liu, Q
    [J]. ICIA 2004: PROCEEDINGS OF 2004 INTERNATIONAL CONFERENCE ON INFORMATION ACQUISITION, 2004, : 436 - 439
  • [30] Methodology for commissioning a brachytherapy treatment planning system in the era of 3D planning
    Dempsey, Claire
    [J]. Australasian Physical and Engineering Sciences in Medicine, 2010, 33 (04): : 341 - 349