Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise

被引:295
|
作者
Hsieh, J [1 ]
机构
[1] GE Co, Med Syst, Appl Sci Lab, Milwaukee, WI 53201 USA
关键词
computed tomography; x-ray photon starvation; streak artifact; adaptive filtering;
D O I
10.1118/1.598410
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The quality of a computed tomography (CT) image is often degraded by streaking artifacts resulting from excessive x-ray quantum noise. Often, a patient has to be rescanned at a higher technique or at a larger slice thickness in order to obtain an acceptable image for diagnosis. This results in a higher dose to the patient, a degraded cross plane resolution, or a reduced patient throughput. In this paper, we propose an adaptive filtering approach in Radon space based on the local statistical properties of the CT projections. We first model the noise characteristics of a projection sample undergoing important preprocessing steps. A filter is then designed such that its parameters are dynamically adjusted to adapt to the local noise characteristics. Because of the adaptive nature of the filter, a proper balance between streak artifact suppression and spatial resolution preservation is achieved. Phantom and clinical studies have been conducted to evaluate the robustness of our approach. Results demonstrate that the adaptive filtering approach is effective in reducing or eliminating quantum noise induced artifacts in CT. At the same time, the impact on the spatial resolution is kept at a low level. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)00311-3].
引用
收藏
页码:2139 / 2147
页数:9
相关论文
共 50 条
  • [41] Metal Artifact Reduction in Cone-Beam X-Ray Computed Tomography Using Statistical Iterative Reconstruction
    Aootaphao, Sorapong
    Pintavirooj, Chuchart
    Sotthivirat, Saowapak
    [J]. ECTI-CON 2008: PROCEEDINGS OF THE 2008 5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY, VOLS 1 AND 2, 2008, : 493 - +
  • [42] Using Experiment and Simulation to Understand the Effects of Source Filtering on Artifact Reduction for Industrial X-ray Computed Tomography
    Roth, Don
    [J]. MATERIALS EVALUATION, 2020, 78 (02) : 203 - 212
  • [43] Image-based Metal Artifact Reduction in X-ray Computed Tomography utilizing Local Anatomical Similarity
    Dong, Xue
    Yang, Xiaofeng
    Rosenfield, Jonathan
    Elder, Eric
    Dhabaan, Anees
    [J]. MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [44] Using Experiment and Simulation to Understand the Effects of Source Filtering on Artifact Reduction for Industrial X-ray Computed Tomography
    [J]. Roth, Don (don.roth@bhge.com), 1600, American Society for Nondestructive Testing (78):
  • [45] Metal Artifact Reduction Based on Beam Hardening Correction and Statistical Iterative Reconstruction for X-ray Computed Tomography
    Zhang, Yanbo
    Mou, Xuanqin
    [J]. MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [46] Statistical X-ray Computed Tomography Imaging from Photon-starved Measurements
    Chang, Zhiqian
    Zhang, Ruoqiao
    Thibault, Jean-Baptiste
    Sauer, Ken
    Bouman, Charles
    [J]. COMPUTATIONAL IMAGING XII, 2014, 9020
  • [47] X-RAY COMPUTED TOMOGRAPHY
    HORN, E
    [J]. ELECTRONICS AND POWER, 1978, 24 (01): : 36 - 41
  • [48] X-ray computed tomography
    Kalender, Willi A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13): : R29 - R43
  • [49] X-ray computed tomography
    Withers, Philip J.
    Bouman, Charles
    Carmignato, Simone
    Cnudde, Veerle
    Grimaldi, David
    Hagen, Charlotte K.
    Maire, Eric
    Manley, Marena
    Du Plessis, Anton
    Stock, Stuart R.
    [J]. NATURE REVIEWS METHODS PRIMERS, 2021, 1 (01):
  • [50] X-RAY COMPUTED TOMOGRAPHY
    HORN, E
    [J]. ELECTRONICS AND POWER, 1978, 24 (03): : 181 - 181