Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise

被引:294
|
作者
Hsieh, J [1 ]
机构
[1] GE Co, Med Syst, Appl Sci Lab, Milwaukee, WI 53201 USA
关键词
computed tomography; x-ray photon starvation; streak artifact; adaptive filtering;
D O I
10.1118/1.598410
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The quality of a computed tomography (CT) image is often degraded by streaking artifacts resulting from excessive x-ray quantum noise. Often, a patient has to be rescanned at a higher technique or at a larger slice thickness in order to obtain an acceptable image for diagnosis. This results in a higher dose to the patient, a degraded cross plane resolution, or a reduced patient throughput. In this paper, we propose an adaptive filtering approach in Radon space based on the local statistical properties of the CT projections. We first model the noise characteristics of a projection sample undergoing important preprocessing steps. A filter is then designed such that its parameters are dynamically adjusted to adapt to the local noise characteristics. Because of the adaptive nature of the filter, a proper balance between streak artifact suppression and spatial resolution preservation is achieved. Phantom and clinical studies have been conducted to evaluate the robustness of our approach. Results demonstrate that the adaptive filtering approach is effective in reducing or eliminating quantum noise induced artifacts in CT. At the same time, the impact on the spatial resolution is kept at a low level. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)00311-3].
引用
收藏
页码:2139 / 2147
页数:9
相关论文
共 50 条
  • [1] Iterative correction applied to streak artifact reduction in an X-ray computed tomography image of the dento-alveolar region
    Atsushi Kondo
    Yoshihiko Hayakawa
    Jian Dong
    Akira Honda
    [J]. Oral Radiology, 2010, 26 : 61 - 65
  • [2] Iterative correction applied to streak artifact reduction in an X-ray computed tomography image of the dento-alveolar region
    Kondo, Atsushi
    Hayakawa, Yoshihiko
    Dong, Jian
    Honda, Akira
    [J]. ORAL RADIOLOGY, 2010, 26 (01) : 61 - 65
  • [3] Metal artifact reduction in x-ray computed tomography (CT) by constrained optimization
    Zhang, Xiaomeng
    Wang, Jing
    Xing, Lei
    [J]. MEDICAL PHYSICS, 2011, 38 (02) : 701 - 711
  • [4] Streak Artifact Reduction in Low Dose Computed Tomography
    Zamyatin, Alexander A.
    Yang, Zhi
    Akino, Naruomi
    Nakanishi, Satoru
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4150 - +
  • [5] NOISE DUE TO PHOTON-COUNTING STATISTICS IN COMPUTED X-RAY TOMOGRAPHY
    CHESLER, DA
    RIEDERER, SJ
    PELC, NJ
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (01) : 64 - 74
  • [6] Metal-induced streak artifact reduction using iterative reconstruction algorithms in x-ray computed tomography image of the dentoalveolar region
    Dong, Jian
    Hayakawa, Yoshihiko
    Kannenberg, Sven
    Kober, Cornelia
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 115 (02): : E63 - E73
  • [7] Metal artifact reduction in x-ray computed tomography: inpainting versus missing value
    Heil, Ulrich
    Gross, Daniel
    Schulze, Ralf
    Schwanecke, Ulrich
    Schoemer, Elmar
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2675 - 2677
  • [8] Prior-Guided Metal Artifact Reduction for Iterative X-Ray Computed Tomography
    Chang, Zhiqian
    Ye, Dong Hye
    Srivastava, Somesh
    Thibault, Jean-Baptiste
    Sauer, Ken
    Bouman, Charles
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (06) : 1532 - 1542
  • [9] A method for zinger artifact reduction in high-energy x-ray computed tomography
    Mertens, J. C. E.
    Williams, J. J.
    Chawla, Nikhilesh
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 800 : 82 - 92
  • [10] Metal Artifact Reduction in X-Ray Computed Tomography Based On Local Anatomical Similarity
    Dong, X.
    Yang, X.
    Rosenfield, J.
    Elder, E.
    Dhabaan, A.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3326 - 3326