Performance evaluation of the variable refrigerant flow (VRF) air-conditioning system subjected to partial and unbalanced thermal loadings

被引:5
|
作者
Enteria, Napoleon [1 ]
Yamaguchi, Hideki [2 ]
Miyata, Masato [2 ]
Sawachi, Takao [2 ]
Kuwasawa, Yasou [1 ]
机构
[1] BRI, 1 Tachihara, Tsukuba, Ibaraki 3050802, Japan
[2] NILIM, 1 Tachihara, Tsukuba, Ibaraki 3050802, Japan
来源
关键词
Air-conditioning system; Variable refrigerant flow; Thermal loading; Energy consumption;
D O I
10.1299/jtst.2016jtst0013
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper shows the performance evaluation of the variable refrigerant flow (VRF) air-conditioning system subjected to partial and unbalanced thermal (cooling and heating) loadings. The one outdoor unit's and two indoor units' VRF system was used as a test specimen in the controlled outdoor chamber in which temperature and humidity were controlled. The indoor chamber thermal loading was controlled from full to partial thermal loadings and from balanced to unbalanced thermal loadings with respect to the specified rated capacity of the test specimen. The purpose of this study is to determine the real performance of the system when it is operating under actual operating situations. The general results show that the system coefficient of performance much depends on the partial and unbalanced thermal loadings. It is shown that the system maximum coefficient of performance occurred at around 50% of the rated thermal loadings. It is shown that as the load balance ratio decreases, the system coefficient of performance decreases, particularly for the cooling operation, due to the increase of compressor speed to support the refrigerant sub-cooling. In the heating operation, the compressor speed increase is very minimal which results in a very small decrease of the system coefficient of performance as the load balance ratio decreases. Based on this study, the system coefficient of performance becomes much different as the system is operating at partial thermal loadings. Also, during the unbalanced thermal loadings, the system coefficient of performance further decreases, particularly during the cooling operation. With the results of the study and analyses of the system operation, it is important to consider how the VRF system operates in an actual building when estimating the energy consumption of the VRF air-conditioning system to be installed in a new or in a retrofitted building.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Exergoenvironmental Evaluation of the Desiccant Air-Conditioning System Subjected to Different Regeneration Temperatures
    Enteria, Napoleon
    Yoshino, Hiroshi
    Sataki, Akira
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2016, 24 (04)
  • [32] Study on thermal performance of air-Type radiation air-conditioning system
    [J]. 1600, Architectural Institute of Japan (82):
  • [33] Optimal control of combined air conditioning system with variable refrigerant flow and variable air volume for energy saving
    Zhu, Yonghua
    Jin, Xinqiao
    Fang, Xing
    Du, Zhimin
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 42 : 14 - 25
  • [34] Performance simulation of a joint solid desiccant heat pump and variable refrigerant flow air conditioning system in EnergyPlus
    Jiang, Yu
    Ge, Tianshu
    Wang, Ruzhu
    [J]. ENERGY AND BUILDINGS, 2013, 65 : 220 - 230
  • [35] A hybrid control strategy for frequency regulation with variable refrigerant flow air conditioning system
    Zhou, Fenglin
    Li, Yaoyu
    Dong, Liujia
    [J]. ENERGY AND BUILDINGS, 2024, 303
  • [36] Online optimal control of variable refrigerant flow and variable air volume combined air conditioning system for energy saving
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    Fang, Xing
    [J]. APPLIED THERMAL ENGINEERING, 2015, 80 : 87 - 96
  • [37] Heating control strategy in fresh air processor matched with variable refrigerant flow air conditioning system
    Tu, Qiu
    Mao, Shoubo
    Feng, Yuhai
    Guo, Defang
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (07) : 2542 - 2554
  • [38] Research and Performance Optimization of Refrigerant Flow Noise in Automotive Air Conditioning System
    Zhang, Zhenyu
    Wang, Linan
    Chen, Jiangping
    [J]. Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2019, 53 (04): : 454 - 460
  • [39] Performance Evaluation and Experimental Study of the Induction Radiant Air-conditioning System
    Si, Qiang
    Zhang, Xiaosong
    [J]. 9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 1795 - 1804
  • [40] State space based modeling and performance evaluation of an air-conditioning system
    Kumar, Mahendra
    Kar, I. N.
    Ray, Anjan
    [J]. HVAC&R RESEARCH, 2008, 14 (05): : 797 - 816