Recent diamond single crystal x-ray optics developments at the European Synchrotron Radiation Facility

被引:10
|
作者
Freund, AK [1 ]
Sellschop, JPF [1 ]
Lieb, K [1 ]
Rony, S [1 ]
Schulze, C [1 ]
Schroeder, L [1 ]
Teyssier, J [1 ]
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
来源
关键词
diamond; single crystals; synchrotron; x-ray optics;
D O I
10.1117/12.332529
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In an effort to provide synchrotron x-ray beamlines with improved monochromators, a new series of 111-oriented diamond crystals up to 50 mm(2) large with thicknesses ranging from 67 mu m to 175 mu m was prepared, tested and found to be of very high quality. One sample appeared to be without any defects. Some linear defects were observed by topography on the other samples but without any consequences for the rocking curve width, except for one sample that revealed some mosaicity in part of its volume and could serve as variable flux/resolution monochromator. The rocking curve width exceeded sometimes the theoretical perfect crystal value by a couple of arcsec. Peak and integrated reflectivities were observed to be very dose to the theoretical values for a perfect diamond crystal. For the first time, a diamond crystal was elastically bent to achieve sagittal focusing. Although the bending was not absolutely uniform, a spot size of 21 mu m and gain factors exceeding one order of magnitude were obtained. These results showed that dispersion-free diamond double crystal monochromators of the classical type can be made.
引用
收藏
页码:53 / 63
页数:11
相关论文
共 50 条
  • [11] MEDIUM POWER X-RAY CRYSTAL OPTICS FOR SYNCHROTRON RADIATION SOURCES
    CERNIK, R
    HART, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 281 (02): : 403 - 405
  • [12] CHARACTERIZATION OF X-RAY OPTICS BY SYNCHROTRON RADIATION
    KUHNE, M
    MULLER, P
    X-RAY INSTRUMENTATION IN MEDICINE AND BIOLOGY, PLASMA PHYSICS, ASTROPHYSICS, AND SYNCHROTRON RADIATION, 1989, 1140 : 220 - 225
  • [13] X-RAY OPTICS AND MONOCHROMATORS FOR SYNCHROTRON RADIATION
    HASTINGS, JB
    JOURNAL OF APPLIED PHYSICS, 1977, 48 (04) : 1576 - 1584
  • [14] A synchrotron radiation facility for x-ray astronomy
    Hall, CJ
    Lewis, RA
    Christensen, FE
    Fraser, G
    Norman, D
    Kent, B
    Owens, A
    Ubertini, P
    GRAZING INCIDENCE AND MULTILAYER X-RAY OPTICAL SYSTEMS, 1997, 3113 : 509 - 514
  • [15] Single crystal CVD diamond for synchrotron X-ray beam monitoring
    Morse, J.
    Salome, M.
    Barrett, R.
    INDUSTRIAL DIAMOND REVIEW, 2006, 66 (03): : 34 - +
  • [16] The Recent Development of an X-ray Grating Interferometer at Shanghai Synchrotron Radiation Facility
    Sun, Haohua
    Kou, Bingquan
    Xi, Yan
    Qi, Juncheng
    Sun, Jianqi
    Mohr, Juergen
    Boerner, Martin
    Zhao, Jun
    Xu, Lisa X.
    Xiao, Tiqiao
    Wang, Yujie
    INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS, 2012, 1466 : 243 - 248
  • [17] Recent developments in synchrotron radiation X-ray scattering on (bio)-polymers.
    Koch, MHJ
    Svergun, DI
    Gabriel, A
    Goderis, B
    Unruh, T
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 222 : U355 - U355
  • [18] POLARIZATION PHENOMENA IN X-RAY OPTICS OF SYNCHROTRON RADIATION
    BELYAKOV, VA
    DMITRIENKO, VE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 282 (2-3): : 526 - 528
  • [19] Surface metrology of X-ray optics for synchrotron radiation
    Ohashi H.
    Seimitsu Kogaku Kaishi/Journal of the Japan Society for Precision Engineering, 2010, 76 (11): : 1239 - 1243
  • [20] Graded X-ray optics for synchrotron radiation applications
    J. Synchrotron Radiat., 3 (239-245):