Real-time two-dimensional imaging in scattering media by use of a femtosecond Cr4+:forsterite laser

被引:26
|
作者
Abraham, E
Bordenave, E
Tsurumachi, N
Jonusauskas, G
Oberlé, J
Rullière, C
Mito, A
机构
[1] Univ Bordeaux 1, Opt & Hertzienne, Ctr Phys Mol, F-33400 Talence, France
[2] Natl Res Lab Metrol, Tsukuba, Ibaraki 305, Japan
关键词
D O I
10.1364/OL.25.000929
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An original femtosecond Cr4+:forsterite laser source associated with a nonlinear optical correlator was used for imaging through scattering media with 1220-nm light. The system, which operates as an ultrafast optical gate by sum-frequency generation in a nonlinear crystal, was able to detect the Light reflected from a resolution chart hidden in a turbid medium, at an attenuation of as much as 15 mean free paths, When the object was illuminated with a collimated beam, real-time two-dimensional images were obtained, with a maximum transverse resolution of similar to 20 mu m. (C) 2000 Optical Society of America. OCIS codes: 320.7110, 320.2250, 290.7050, 290.1990, 290.1350.
引用
收藏
页码:929 / 931
页数:3
相关论文
共 50 条
  • [41] REAL-TIME TWO-DIMENSIONAL BLOOD-FLOW IMAGING USING AN AUTOCORRELATION TECHNIQUE
    KASAI, C
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1986, 33 (01) : 94 - 94
  • [42] REAL-TIME TWO-DIMENSIONAL BLOOD-FLOW IMAGING USING ULTRASOUND DOPPLER
    KASAI, C
    NAMEKAWA, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1987, 26 : 9 - 13
  • [43] Improved two-dimensional product imaging: The real-time ion-counting method
    Chang, BY
    Hoetzlein, RC
    Mueller, JA
    Geiser, JD
    Houston, PL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (04): : 1665 - 1670
  • [44] Two-dimensional spectroscopy by spectrally resolved real-time resonant coherent Raman scattering in polydiacetylene
    Ishii, N
    Tokunaga, E
    Adachi, S
    Kimura, T
    Matsuda, H
    Kobayashi, T
    ULTRAFAST PHENOMENA XIV, 2005, 79 : 563 - 565
  • [45] Single-Shot Real-Time Ultrafast Imaging of Femtosecond Laser Fabrication
    Yao, Yunhua
    He, Yilin
    Qi, Dalong
    Cao, Fengyan
    Yao, Jiali
    Ding, Pengpeng
    Jin, Chengzhi
    Wu, Xianyu
    Deng, Lianzhong
    Jia, Tianqing
    Huang, Feng
    Liang, Jinyang
    Sun, Zhenrong
    Zhang, Shian
    ACS PHOTONICS, 2021, 8 (03): : 738 - 744
  • [46] Real time imaging of two-dimensional charge on dielectric surfaces
    Budakian, R
    Putterman, SJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02): : 444 - 449
  • [48] Two-dimensional resolution pyrometer for real-time monitoring of temperature image in laser materials processing
    Ignatiev, M
    Smurov, IY
    Flamant, G
    Senchenko, V
    Dozhdikov, V
    APPLIED SURFACE SCIENCE, 1997, 109 : 498 - 508
  • [49] A two-dimensional transducer array for real-time 3D medical ultrasound imaging
    Bureau, JM
    Steichen, W
    Lebail, G
    1998 IEEE ULTRASONICS SYMPOSIUM - PROCEEDINGS, VOLS 1 AND 2, 1998, : 1065 - 1068
  • [50] ULTRASOUND ANGIOSCOPY - REAL-TIME, TWO-DIMENSIONAL, INTRALUMINAL ULTRASOUND IMAGING OF BLOOD-VESSELS
    PANDIAN, NG
    KREIS, A
    BROCKWAY, B
    ISNER, JM
    SACHAROFF, A
    BOLEZA, E
    CARO, R
    MULLER, D
    AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (07): : 493 - 494