Associations of indoor carbon dioxide concentrations, air temperature, and humidity with perceived air quality and sick building syndrome symptoms in Chinese homes

被引:43
|
作者
Hou, Jing [1 ]
Sun, Yuexia [1 ]
Dai, Xilei [1 ]
Liu, Junjie [1 ]
Shen, Xiong [1 ]
Tan, Hongwei [2 ]
Yin, Haiguo [3 ]
Huang, Kailiang [4 ]
Gao, Yao [5 ]
Lai, Dayi [1 ,6 ]
Hong, Weiping [1 ]
Zhai, Xinping [3 ]
Norback, Dan [7 ,8 ]
Chen, Qingyan [9 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin Key Lab Indoor Air Environm Qual Control, Tianjin 300350, Peoples R China
[2] Tongji Univ, Sch Mech Engn, Shanghai, Peoples R China
[3] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian, Shaanxi, Peoples R China
[4] Shenyang Jianzhu Univ, Dept Municipal & Environm Engn, Shenyang, Peoples R China
[5] Shenzhen Inst Bldg Res Co Ltd, Shenzhen, Peoples R China
[6] Shanghai Jiao Tong Univ, Sch Design, Dept Architecture, Shanghai, Peoples R China
[7] Uppsala Univ, Dept Med Sci, Uppsala, Sweden
[8] Univ Hosp, Uppsala, Sweden
[9] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
基金
中国国家自然科学基金;
关键词
CO2; home; odors; perceived dry air; relative humidity; sick building syndrome; RELATIVE-HUMIDITY; ORGANIC-COMPOUNDS; VOC EMISSIONS; VENTILATION; HEALTH; EXPOSURE; DAMPNESS; DRYNESS; IMPACT; TIME;
D O I
10.1111/ina.12810
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The indoor environment influences occupants' health. From March 1, 2018, to February 28, 2019, we continuously monitored indoor temperature (T), relative humidity (RH), and CO2 concentration in bedrooms via an online system in 165 residences that covered all five climate zones of China. Meanwhile, we asked one specific occupant in each home to complete questionnaires about perceived air quality and sick building syndrome (SBS) symptoms at the end of each month. Higher CO2 concentration was significantly associated with a higher percentage of perceived stuffy odor and skin SBS symptoms. Higher relative humidity was associated with higher percentage of perceived moldy odor and humid air, while lower RH was associated with a higher percentage of perceived dry air. Occupants who lived in residences with high RH were less likely to have mucosal and skin SBS symptoms (adjusted odds ratio (AOR): 0.73-0.78). However, the benefit of high humidity for perceived dry air and skin dryness symptoms is weaker if there is a high CO2 concentration level.
引用
收藏
页码:1018 / 1028
页数:11
相关论文
共 50 条
  • [41] Dampness and mould in Chinese homes and sick building syndrome (SBS) symptoms - Associations with climate, family size, cleaning and ventilation
    Zhang, Bin
    Norback, Dan
    Cheng, Hong
    Li, Baizhan
    Zhang, Yinping
    Zhao, Zhuohui
    Deng, Qihong
    Huang, Chen
    Yang, Xu
    Lu, Chan
    Qian, Hua
    Wang, Tingting
    Zhang, Ling
    Yu, Wei
    Wang, Juan
    Zhang, Xin
    BUILDING AND ENVIRONMENT, 2023, 245
  • [42] Influence of heating systems on indoor air quality and sick building syndrome (a case study in Qom, Iran)
    Salari, Mehdi
    Tabatabaei, Fatemeh Sadat
    Fouladi-Fard, Reza
    Mohammadbeigi, Abolfazl
    Nadali, Azam
    Fahiminia, Mohammad
    Fiore, Maria
    INTERNATIONAL JOURNAL OF VENTILATION, 2023, 22 (03) : 257 - 272
  • [43] Indoor Air Quality of Tottori University Lecture Rooms and Measures for Decreasing Carbon Dioxide Concentrations
    Houri, Daisuke
    Kanazawa, Yousuke
    Morioka, Ikuharu
    Matsumoto, Kenji
    YONAGO ACTA MEDICA, 2009, 52 (02) : 77 - 84
  • [44] The effect of structures on indoor humidity - possibility to improve comfort and perceived air quality
    Simonson, CJ
    Salonvaara, M
    Ojanen, T
    INDOOR AIR, 2002, 12 (04) : 243 - 251
  • [45] Use of portable air purifiers in homes: Operating behaviour, effect on indoor PM2.5 and perceived indoor air quality
    Cooper, Elizabeth
    Wang, Yan
    Stamp, Samuel
    Burman, Esfandiar
    Mumovic, Dejan
    BUILDING AND ENVIRONMENT, 2021, 191
  • [46] INFLUENCE OF INDOOR AIR-QUALITY AND PERSONAL FACTORS ON THE SICK BUILDING SYNDROME (SBS) IN SWEDISH GERIATRIC HOSPITALS
    NORDSTROM, K
    NORBACK, D
    AKSELSSON, R
    OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1995, 52 (03) : 170 - 176
  • [47] Relationship of multiple indoor air pollutants and sick building syndrome at air-conditioned office buildings in Taiwan
    Wu, PC
    Li, YY
    Chiang, CM
    Su, HJ
    Lee, CC
    EPIDEMIOLOGY, 2004, 15 (04) : S16 - S16
  • [48] Effects of ventilation rate per person and per floor area on perceived air quality, sick building syndrome symptoms, and decision-making
    Maddalena, R.
    Mendell, M. J.
    Eliseeva, K.
    Chan, W. R.
    Sullivan, D. P.
    Russell, M.
    Satish, U.
    Fisk, W. J.
    INDOOR AIR, 2015, 25 (04) : 362 - 370
  • [49] Influences of Temperature and Humidity on Perceived Air Quality with Radiant Panel Workstation
    He, Meiling
    Li, Nianping
    He, Yingdong
    He, De
    Wang, Kuan
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 765 - 772
  • [50] Psychosocial Problems, Indoor Air-Related Symptoms, and Perceived Indoor Air Quality among Students in Schools without Indoor Air Problems: A Longitudinal Study
    Finell, Eerika
    Tolvanen, Asko
    Pekkanen, Juha
    Minkkinen, Jaana
    Stahl, Timo
    Rimpela, Arja
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (07)