An comparison of acute toxicities and patient-reported outcomes between intensity-modulated proton therapy and volumetric-modulated arc therapy after ipsilateral radiation for head and neck cancers

被引:9
|
作者
Jeans, Elizabeth B. [1 ]
Shiraishi, Satomi [1 ]
Manzar, Gohar [1 ]
Morris, Lindsay K. [1 ]
Amundson, Adam [1 ]
McGee, Lisa A. [2 ]
Rwigema, Jean-Claude [2 ]
Neben-Wittich, Michelle [1 ]
Routman, David M. [1 ]
Ma, Daniel J. [1 ]
Patel, Samir H. [2 ]
Foote, Robert L. [1 ]
Lester, Scott C. [1 ]
机构
[1] Mayo Clin, Dept Radiat Oncol, 200 First St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Radiat Oncol, Phoenix, AZ USA
关键词
head and neck cancer; IMPT; ipsilateral neck radiotherapy; proton radiotherapy; tonsil and salivary cancer; SQUAMOUS-CELL CARCINOMA; RADIOTHERAPY; IMPT; IMRT;
D O I
10.1002/hed.26937
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
BACKGROUND Intensity-modulated proton therapy (IMPT) demonstrates superior dose distribution over volumetric-modulated arc therapy (VMAT) for sparing organs-at-risk (OARs) in ipsilateral radiotherapy. To determine a clinical benefit, assessment of patient-reported outcomes (PRO) and physician-reported toxicities alongside a dosimetric analysis is needed. METHODS Plans were analyzed for dosimetric differences. PROs were compared for patients undergoing ipsilateral curative-intent radiotherapy for tonsil and salivary gland cancers with VMAT or IMPT from 2015 to 2020. Physician-reported toxicities were compared. RESULTS In 40 patients, IMPT was associated with decreased dose to multiple OARs and less deterioration in the following PROs: pain, swallowing function, dry mouth, sticky saliva, sensory change, cough, speech, feeling ill, and social eating. Physician-reported toxicities demonstrated less oral pain. CONCLUSION IMPT is associated with decreased dose to OARs and less patient-reported acute deterioration in multiple head and neck domains. A strong consideration for IMPT in ipsilateral head and neck patients with cancer is warranted.
引用
收藏
页码:359 / 371
页数:13
相关论文
共 50 条
  • [31] Effects of full-neck volumetric-modulated arc therapy vs split-field intensity-modulated head and neck radiation therapy on low neck targets and structures
    Anamalayil, Shibu J.
    Teo, Boon-Keng K.
    Lin, Alexander
    Lustig, Robert A.
    Ahn, Peter H.
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1062):
  • [32] Evaluation of Healthy Tissue Dose at Different Regions between Volumetric-Modulated Arc Therapy and Intensity-Modulated Radiation Therapy Plans in the Treatment of Various Cancers
    Krishnan, Jayapalan
    Rao, Suresh
    Hegde, Sanath
    Shetty, Jayarama
    JOURNAL OF MEDICAL PHYSICS, 2019, 44 (03) : 213 - 221
  • [33] A prospective trial of volumetric intensity-modulated arc therapy vs conventional intensity modulated radiation therapy in advanced head and neck cancer
    Fung-Kee-Fung, Simon D.
    Hackett, Rachel
    Hales, Lee
    Warren, Graham
    Singh, Anurag K.
    WORLD JOURNAL OF CLINICAL ONCOLOGY, 2012, 3 (04): : 57 - 62
  • [34] Comparison of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy in the treatment of cervical esophageal carcinoma
    Yang, Hao
    Feng, Cong
    Cai, Bo-Ning
    Yang, Jun
    Liu, Hai-Xia
    Ma, Lin
    DISEASES OF THE ESOPHAGUS, 2017, 30 (02):
  • [35] Late Toxicities of Intensity-Modulated Radiation Therapy for Head and Neck Rhabdomyosarcoma
    Lockney, Natalie A.
    Friedman, Danielle Novetsky
    Wexler, Leonard H.
    Sklar, Charles A.
    Casey, Dana L.
    Wolden, Suzanne L.
    PEDIATRIC BLOOD & CANCER, 2016, 63 (09) : 1608 - 1614
  • [36] Evaluation of Integral Dose in Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy for Head and Neck Cancer Patient
    Al-Basheer, A.
    Hunag, J.
    Kaminski, J.
    Dasher, B.
    Howington, J.
    Stewart, J.
    Martin, D.
    Kong, F.
    Jin, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 260 - 261
  • [37] Hypofractionated radiation therapy for head and neck cancers in the era of intensity-modulated radiation therapy
    Eom, Keun-Yong
    RADIATION ONCOLOGY JOURNAL, 2024, 42 (01): : 1 - 3
  • [38] Intensity-modulated proton therapy (IMPT) versus intensity-modulated radiation therapy (IMRT) for the treatment of head and neck cancer: A dosimetric comparison
    Nguyen, My-Lien
    Cantrell, J. Nathan
    Ahmad, Salahuddin
    Henson, Christina
    MEDICAL DOSIMETRY, 2021, 46 (03) : 259 - 263
  • [39] Comparison of testicular dose delivered by intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with prostate cancer
    Martin, Jeffrey M.
    Handorf, Elizabeth A.
    Price, Robert A.
    Cherian, George
    Buyyounouski, Mark K.
    Chen, David Y.
    Kutikov, Alexander
    Johnson, Matthew E.
    Ma, Chung-Ming Charlie
    Horwitz, Eric M.
    MEDICAL DOSIMETRY, 2015, 40 (03) : 186 - 189
  • [40] Intensity-modulated radiation therapy in head and neck cancers: The Mallinckrodt experience
    Chao, KSC
    Low, DA
    Perez, CA
    Purdy, JA
    INTERNATIONAL JOURNAL OF CANCER, 2000, 90 (02) : 92 - 103