Evaluating the temporomandibular joint disc using calcium-suppressed technique in dual-layer detector computed tomography

被引:1
|
作者
Zhang, Xiaohuan [1 ]
Liu, Mengqi [1 ,2 ]
Wang, Yanyi [3 ]
Deng, Weiwei [4 ]
Tan, Houmin [4 ]
Fan, Wenping [1 ]
Chen, Zhiye [1 ,2 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Radiol, Hainan Hosp, Sanya 572013, Hainan, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Radiol, Beijing, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Hainan Hosp, Dept Stomatol, Sanya, Hainan, Peoples R China
[4] Philips Healthcare China, Shanghai, Peoples R China
关键词
Temporomandibular disorders; temporomandibular joint; dual-layer detector CT; spectral detector CT; magnetic resonance imaging; calcium-suppressed technique; BONE-MARROW EDEMA; ENERGY CT; QUANTITATIVE PARAMETERS; PREOPERATIVE DIAGNOSIS; FRACTURES; CANCER; ACCURACY;
D O I
10.1177/0300060519891332
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives To investigate the application value of the calcium-suppressed (CaSupp) images of dual-layer detector computed tomography (DLCT) in the evaluation of the temporomandibular joint (TMJ) discs. Methods Thirty-three healthy subjects underwent DLCT and magnetic resonance imaging (MRI) examinations. CaSupp images were reconstructed from the spectral-based images using a calcium suppression algorithm. The location, morphology, and thickness of the posterior band of the TMJ discs were evaluated on the oblique sagittal proton-density weighted images and CaSupp images. Results Of the 66 TMJ discs, anterior displacement was observed on 9 TMJ discs on MR images and 6 TMJ discs on CaSupp images, and posterior displacement was present on 3 TMJ discs on MR and CaSupp images. No significant difference was observed in TMJ disc displacement between MR images and CaSupp images (P value = 0.730). The TMJ discs without displacement had no significant difference in the thickness of the posterior band between the MR and CaSupp images (P value = 0.401). Conclusions The calcium-suppressed technique in DLCT may be a simple and preliminary way to evaluate the TMJ disc displacement and structure.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Feasibility and accuracy of dual-layer spectral detector computed tomography for quantification of gadolinium: a phantom study
    van Hamersvelt, Robbert W.
    Willemink, Martin J.
    de Jong, Pim A.
    Milles, Julien
    Vlassenbroek, Alain
    Schilham, Arnold M. R.
    Leiner, Tim
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3677 - 3686
  • [12] Calcium decomposition and phantomless bone mineral density measurements using dual-layer based spectral computed tomography
    Mei, Kai
    Schwaiger, Benedikt J.
    Kopp, Felix K.
    Ehn, Sebastian
    Gersing, Alexandra S.
    Kirschke, Jan S.
    Muenzel, Daniela
    Fingerle, Alexander A.
    Rummeny, Ernst J.
    Pfeiffer, Franz
    Baum, Thomas
    Noel, Peter B.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [13] Evaluation of Virtual Monoenergetic Images on Pulmonary Vasculature Using the Dual-Layer Detector-Based Spectral Computed Tomography
    Ghandour, Abed
    Sher, Andrew
    Rassouli, Negin
    Dhanantwari, Amar
    Rajiah, Prabhakar
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 858 - 865
  • [14] Clinical Usefulness of Dual-Energy Cardiac Computed Tomography in Acute Coronary Syndrome Using a Dual-Layer Spectral Detector Scanner
    Nishihara, Taiki
    Oda, Seitaro
    Sueta, Daisuke
    Izumiya, Yasuhiro
    Kaikita, Koichi
    Tsujita, Kenichi
    Utsunomiya, Daisuke
    Nakaura, Takeshi
    Yamashita, Yasuyuki
    CIRCULATION-CARDIOVASCULAR IMAGING, 2018, 11 (02)
  • [15] Bone marrow edema in traumatic vertebral compression fractures: Diagnostic accuracy of dual-layer detector CT using calcium suppressed images
    Neuhaus, Victor
    Lennartz, Simon
    Abdullayev, Nuran
    Hokamp, Nils Grosse
    Shapira, Nadav
    Kafri, Galit
    Holz, Jasmin A.
    Krug, Barbara
    Hellmich, Martin
    Maintz, David
    Borggrefe, Jan
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 : 216 - 220
  • [16] Quantitative analysis of late iodine enhancement using dual-layer spectral detector computed tomography: comparison with magnetic resonance imaging
    Liu, Peijun
    Lin, Lu
    Xu, Cheng
    Han, Yechen
    Lin, Xue
    Hou, Yang
    Lu, Xiaomei
    Vembar, Mani
    Jin, Zhengyu
    Wang, Yining
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (01) : 310 - 320
  • [17] Usefulness and limitations of dual-layer spectral detector computed tomography for diagnosing biliary stones not detected by conventional computed tomography: a report of three cases
    Saito H.
    Noda K.
    Ogasawara K.
    Atsuji S.
    Takaoka H.
    Kajihara H.
    Nasu J.
    Morishita S.
    Matsushita I.
    Katahira K.
    Clinical Journal of Gastroenterology, 2018, 11 (2) : 172 - 177
  • [18] Metal artifact reduction by dual-layer computed tomography using virtual monoenergetic images
    Neuhaus, Victor
    Hokamp, Nils Grosse
    Abdullayev, Nuran
    Rau, Robert
    Mpotsaris, Anastasios
    Maintz, David
    Borggrefe, Jan
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 93 : 143 - 148
  • [19] Spectral imaging with dual-layer spectral detector computed tomography for the detection of perfusion defects in acute coronary syndrome
    Mochizuki, Junji
    Nakaura, Takeshi
    Yoshida, Naofumi
    Nagayama, Yasunori
    Kidoh, Masafumi
    Uetani, Hiroyuki
    Funama, Yoshinori
    Hata, Yoshiki
    Azuma, Minako
    Hirai, Toshinori
    HEART AND VESSELS, 2022, 37 (07) : 1115 - 1124
  • [20] Dual-layer spectral detector computed tomography multiparameter machine learning model for prediction of invasive lung adenocarcinoma
    Wan, Jiayu
    Lin, Xue
    Wang, Zhaokai
    Sun, Peng
    Gui, Shen
    Ye, Tianhe
    Fan, Qianqian
    Liu, Weiwei
    Pan, Feng
    Yang, Bo
    Geng, Xiaotong
    Quan, Zhen
    Yang, Lian
    TRANSLATIONAL LUNG CANCER RESEARCH, 2025, 14 (02)