Evaluating the temporomandibular joint disc using calcium-suppressed technique in dual-layer detector computed tomography

被引:1
|
作者
Zhang, Xiaohuan [1 ]
Liu, Mengqi [1 ,2 ]
Wang, Yanyi [3 ]
Deng, Weiwei [4 ]
Tan, Houmin [4 ]
Fan, Wenping [1 ]
Chen, Zhiye [1 ,2 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Radiol, Hainan Hosp, Sanya 572013, Hainan, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Radiol, Beijing, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Hainan Hosp, Dept Stomatol, Sanya, Hainan, Peoples R China
[4] Philips Healthcare China, Shanghai, Peoples R China
关键词
Temporomandibular disorders; temporomandibular joint; dual-layer detector CT; spectral detector CT; magnetic resonance imaging; calcium-suppressed technique; BONE-MARROW EDEMA; ENERGY CT; QUANTITATIVE PARAMETERS; PREOPERATIVE DIAGNOSIS; FRACTURES; CANCER; ACCURACY;
D O I
10.1177/0300060519891332
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives To investigate the application value of the calcium-suppressed (CaSupp) images of dual-layer detector computed tomography (DLCT) in the evaluation of the temporomandibular joint (TMJ) discs. Methods Thirty-three healthy subjects underwent DLCT and magnetic resonance imaging (MRI) examinations. CaSupp images were reconstructed from the spectral-based images using a calcium suppression algorithm. The location, morphology, and thickness of the posterior band of the TMJ discs were evaluated on the oblique sagittal proton-density weighted images and CaSupp images. Results Of the 66 TMJ discs, anterior displacement was observed on 9 TMJ discs on MR images and 6 TMJ discs on CaSupp images, and posterior displacement was present on 3 TMJ discs on MR and CaSupp images. No significant difference was observed in TMJ disc displacement between MR images and CaSupp images (P value = 0.730). The TMJ discs without displacement had no significant difference in the thickness of the posterior band between the MR and CaSupp images (P value = 0.401). Conclusions The calcium-suppressed technique in DLCT may be a simple and preliminary way to evaluate the TMJ disc displacement and structure.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Calcium-Suppressed Technique in Dual-layer Detector Computed Tomography to Evaluate Knee Articular Cartilage
    Meng, Qinglin
    Liu, Mengqi
    Deng, Weiwei
    Chen, Ke
    Wang, Botao
    Zhang, Xiaohuan
    Chen, Zhiye
    CURRENT MEDICAL IMAGING, 2021, 17 (03) : 433 - 438
  • [2] Assessment of solitary pulmonary nodules using dual-layer spectral detector computed tomography
    Ko, Tse-Pang
    Chang, Yu-Pin
    Chai, Jyh-Wen
    MEDICINE, 2024, 103 (41)
  • [3] Early rectal neoplasm in dual-layer spectral detector computed tomography: dual-layer spectral computed tomography (CT) images improve tumor detection and staging
    Pan, Xuelin
    Wu, Zhihan
    Zhao, Jin
    Zhang, Xinyi
    Zhang, Xiaodi
    Tang, Li
    Yang, Jinlin
    Deng, Kai
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (12) : 8260 - 8271
  • [4] Dual-energy computed tomography colonography using dual-layer spectral detector computed tomography: Utility of virtual monochromatic imaging for electronic cleansing
    Taguchi, Narumi
    Oda, Seitaro
    Imuta, Masanori
    Yamamura, Sadahiro
    Yokota, Yasuhiro
    Nakaura, Takeshi
    Nagayama, Yasunori
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Baba, Hideo
    Yamashita, Yasuyuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 108 : 7 - 12
  • [5] Dynamic evaluation of myocardial extracellular volume fraction using dual-layer spectral detector computed tomography
    Kidoh, Masafumi
    Oda, Seitaro
    Takashio, Seiji
    Tsujita, Kenichi
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2020, 4 (06)
  • [6] Use of dual-layer spectral detector computed tomography in the diagnosis of pancreatic neuroendocrine neoplasms
    Yuan, Jiaxin
    Wang, Yangdi
    Hu, Xuefang
    Shi, Siya
    Zhang, Ning
    Wang, Liqin
    Deng, Weiwei
    Feng, Shi-Ting
    Peng, Zhenpeng
    Luo, Yanji
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 159
  • [7] The application of dual-layer spectral detector computed tomography in solitary pulmonary nodule identification
    Wen, Qingyun
    Yue, Yong
    Shang, Jin
    Lu, Xiaomei
    Gao, Lu
    Hou, Yang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (02) : 521 - +
  • [8] Quantitative parameters of dual-layer spectral detector computed tomography for evaluating differentiation grade and lymphovascular and perineural invasion in colorectal adenocarcinoma
    Chen, Jinghua
    Ni, Lei
    Gong, Jingjing
    Wu, Jie
    Qian, Tingting
    Wang, Mengjia
    Huang, Jian
    Liu, Kefu
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 178
  • [9] Dual-layer spectral detector computed tomography versus magnetic resonance cholangiopancreatography for biliary stones
    Saito, Hirokazu
    Iwagoi, Yuki
    Noda, Kana
    Atsuji, Shutaro
    Takaoka, Hiroko
    Kajihara, Hiroo
    Shono, Takashi
    Nasu, Jiro
    Obara, Hitoshi
    Kakuma, Tatsuyuki
    Tada, Shuji
    Morishita, Shoji
    Matsushita, Ikuo
    Katahira, Kazuhiro
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2021, 33 (01) : 32 - 39
  • [10] Feasibility and accuracy of dual-layer spectral detector computed tomography for quantification of gadolinium: a phantom study
    Robbert W. van Hamersvelt
    Martin J. Willemink
    Pim A. de Jong
    Julien Milles
    Alain Vlassenbroek
    Arnold M. R. Schilham
    Tim Leiner
    European Radiology, 2017, 27 : 3677 - 3686