Advances in cardiac CT imaging: 64-slice scanner

被引:107
|
作者
Nikolaou, K
Flohr, T
Knez, A
Rist, C
Wintersperger, B
Johnson, T
Reiser, MF
Becker, CR
机构
[1] Univ Munich, Dept Clin Radiol, Univ Hosp Grosshadern, D-81377 Munich, Germany
[2] Siemens Med Solut, Forchheim, Germany
[3] Univ Munich, Dept Internal Med 1, Univ Hosp Grosshadern, D-81377 Munich, Germany
来源
关键词
D O I
10.1007/s10554-004-7015-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Clinical progress by the development of multi-slice CT (MSCT) technology beyond 16 slices can more likely be expected from further improved spatial and temporal resolution rather than from a mere increase in the volume coverage speed. We present an evaluation of a recently introduced 64-slice CT (64SCT) system, which makes use of a periodic motion of the focal spot in the longitudinal direction (z-flying focal spot) to double the number of simultaneously acquired slices. Materials and Methods: A recently introduced 64SCT system (SOMATOM Sensation 64, Siemens Medical Solutions, Forchheim, Germany) is being described and tested in first clinical practice, applying the following parameters: z-flying focal spot technology, 64 x 0.6 mm slices; spatial resolution, 0.4 x 0.4 x 0.4 mm; gantry rotation time, 330 ms; temporal resolution, 83-165 ms. Various phantom studies and first clinically implemented protocols are being described, to evaluate the full spectrum of possible applications for this scanner type, with a focus on cardiac imaging. Results:ECG-gated cardiac scanning with this 64-slice CT system benefits clearly from both the improved temporal resolution and improved spatial resolution. These benefits enable a more reliable assessment of mixed plaques, due to reduced partial-voluming and beam-hardening artefacts caused by calcifications, and holds great promise for the reliable assessment of in-stent stenoses, as stent lumen visibility is clearly improved as compared to earlier MSCT systems. With the increased volume coverage and acquisition speed of the 64SCT system, a comprehensive emergency protocol of the thorax becomes feasible within an acceptable breath-hold time, performing an ECG-gated CT angiography of the complete thoracic vasculature. This protocol enables a detailed assessment of the thoracic aorta, the pulmonary arteries and the coronary arteries in one single examination. Conclusion: 64SCT Cardiac imaging provides an increased spatial resolution with an isotropic voxel size of 0.4 mm and an improved temporal resolution of 83-165 ms. These benefits hold great promise especially for fast-moving organs requiring detailed imaging, such as the heart and coronary arteries.
引用
收藏
页码:535 / 540
页数:6
相关论文
共 50 条
  • [21] First experience with monochromatic coronary computed tomography angiography from a 64-slice CT scanner with Gemstone Spectral Imaging (GSI)
    Fuchs, Tobias A.
    Stehli, Julia
    Fiechter, Michael
    Dougoud, Suetlana
    Gebhard, Catherine
    Ghadri, Jelena R.
    Husmann, Lars
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2013, 7 (01) : 25 - 31
  • [22] Radiation dose for cardiac CT angiography - A comparison between dual source and 64-slice CT
    Hermann, Franziska
    Meyer, Tanja
    Hadamitzky, Martin
    Hendrich, Eva
    Lang, Ute
    Schwarzer, Christine
    Martinoff, Stefan
    Hausleiter, Joerg
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A142 - A142
  • [23] Cardiac magnetic resonance and 64-slice cardiac CT of lipomatous metaplasia of chronic myocardial infarction
    Deux, Jean-Francois
    Rahmouni, Alain
    Garot, Jerome
    EUROPEAN HEART JOURNAL, 2008, 29 (04) : 570 - 570
  • [24] The Influence of X-ray Spectra Filtration on Image Quality and Patient Dose in the GE VCT 64-Slice Cardiac CT Scanner
    Ay, M. R.
    Ahmadian, A.
    Ghadiri, H.
    Maleki, A.
    Ghafarian, P.
    Zaidi, H.
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2388 - +
  • [25] A Novel Approach for Experimental Measurement of Scatter Profile and Scatter to Primary Ratio in 64-Slice CT Scanner
    Akbarzadeh, A.
    Ay, M. R.
    Ghadiri, H.
    Sarkar, S.
    Zaidi, H.
    4TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2008, VOLS 1 AND 2, 2008, 21 (1-2): : 473 - +
  • [26] Evaluation of dose exposure in 64-slice CT colonography
    O. Luz
    M. Buchgeister
    M. Klabunde
    T. Trabold
    A. F. Kopp
    C. D. Claussen
    M. Heuschmid
    European Radiology, 2007, 17 : 2616 - 2621
  • [27] Determination of cardiac allograft vasculaopthy in heart transplant patients with 64-slice multislice CT
    Knez, A.
    Von Ziegler, F.
    Kaczmarek, I.
    Leber, A.
    Becker, C.
    Becker, A.
    EUROPEAN HEART JOURNAL, 2006, 27 : 144 - 144
  • [28] Coronary ostial involvement in acute aortic dissection: detection with 64-slice cardiac CT
    Ryan, E. Ronan
    Martos, Ramon
    O'Neill, Ailbhe
    Mc Creery, Charles
    Dodd, Jonathan D.
    CLINICAL IMAGING, 2009, 33 (06) : 471 - 473
  • [29] Use of 64-slice tomodensitometry after cardiac arrest
    Toussaint, M.
    Meyer, P.
    Peraton, A.
    Choukroun, G.
    Gonin, S.
    Amrar-Vennier, F.
    Goube, P.
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 2011, 60 (05): : 282 - 284
  • [30] 64-slice CT: a comparison with invasive coronary angiography
    Ruth Kirby
    Nature Clinical Practice Cardiovascular Medicine, 2005, 2 (11): : 552 - 552