Advances in cardiac CT imaging: 64-slice scanner

被引:107
|
作者
Nikolaou, K
Flohr, T
Knez, A
Rist, C
Wintersperger, B
Johnson, T
Reiser, MF
Becker, CR
机构
[1] Univ Munich, Dept Clin Radiol, Univ Hosp Grosshadern, D-81377 Munich, Germany
[2] Siemens Med Solut, Forchheim, Germany
[3] Univ Munich, Dept Internal Med 1, Univ Hosp Grosshadern, D-81377 Munich, Germany
来源
关键词
D O I
10.1007/s10554-004-7015-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Clinical progress by the development of multi-slice CT (MSCT) technology beyond 16 slices can more likely be expected from further improved spatial and temporal resolution rather than from a mere increase in the volume coverage speed. We present an evaluation of a recently introduced 64-slice CT (64SCT) system, which makes use of a periodic motion of the focal spot in the longitudinal direction (z-flying focal spot) to double the number of simultaneously acquired slices. Materials and Methods: A recently introduced 64SCT system (SOMATOM Sensation 64, Siemens Medical Solutions, Forchheim, Germany) is being described and tested in first clinical practice, applying the following parameters: z-flying focal spot technology, 64 x 0.6 mm slices; spatial resolution, 0.4 x 0.4 x 0.4 mm; gantry rotation time, 330 ms; temporal resolution, 83-165 ms. Various phantom studies and first clinically implemented protocols are being described, to evaluate the full spectrum of possible applications for this scanner type, with a focus on cardiac imaging. Results:ECG-gated cardiac scanning with this 64-slice CT system benefits clearly from both the improved temporal resolution and improved spatial resolution. These benefits enable a more reliable assessment of mixed plaques, due to reduced partial-voluming and beam-hardening artefacts caused by calcifications, and holds great promise for the reliable assessment of in-stent stenoses, as stent lumen visibility is clearly improved as compared to earlier MSCT systems. With the increased volume coverage and acquisition speed of the 64SCT system, a comprehensive emergency protocol of the thorax becomes feasible within an acceptable breath-hold time, performing an ECG-gated CT angiography of the complete thoracic vasculature. This protocol enables a detailed assessment of the thoracic aorta, the pulmonary arteries and the coronary arteries in one single examination. Conclusion: 64SCT Cardiac imaging provides an increased spatial resolution with an isotropic voxel size of 0.4 mm and an improved temporal resolution of 83-165 ms. These benefits hold great promise especially for fast-moving organs requiring detailed imaging, such as the heart and coronary arteries.
引用
收藏
页码:535 / 540
页数:6
相关论文
共 50 条
  • [1] Advances in cardiac CT imaging: 64-slice scanner
    Konstantin Nikolaou
    Thomas Flohr
    Andreas Knez
    Carsten Rist
    Bernd Wintersperger
    Thorsten Johnson
    Maximilian F. Reiser
    Christoph R. Becker
    The International Journal of Cardiovascular Imaging, 2004, 20 : 535 - 540
  • [2] Characterization of Solid Renal Masses using 64-Slice Multidetector CT Scanner
    El-Esawy, Saleh S.
    Abou El-Ghar, Mohamed E.
    Gaballa, Ghada M.
    Zahra, Saly A.
    THESCIENTIFICWORLDJOURNAL, 2009, 9 : 441 - 448
  • [3] Cardiac carcinoid: tricuspid delayed hyperenhancement on cardiac 64-slice multidetector CT and magnetic resonance imaging
    R. Martos
    C. Ridge
    M. Quinn
    J. Dodd
    Irish Journal of Medical Science, 2010, 179 : 447 - 449
  • [4] Cardiac carcinoid: tricuspid delayed hyperenhancement on cardiac 64-slice multidetector CT and magnetic resonance imaging
    Martos, R.
    Ridge, C.
    Quinn, M.
    Dodd, J.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2010, 179 (03) : 447 - 449
  • [5] Application of 64-slice Spiral CT in coronary artery imaging
    Wang, Jiaoyang
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2020, 70 (10) : 2 - 8
  • [6] Imaging by 64-slice CT accurately diagnoses stenosis in CABG
    Nature Clinical Practice Cardiovascular Medicine, 2006, 3 (8): : 404 - 405
  • [7] Radiation Dose to the Breast by 64-slice CT: Effects of Scanner Model and Study Protocol
    Qi, Zhihua
    Lemen, Lisa C.
    Lamba, Michael
    Chen, Hua-Hsuan
    Samaratunga, Ranasinghage
    Mahoney, Mary
    Hendrick, R. Edward
    ACADEMIC RADIOLOGY, 2016, 23 (08) : 987 - 993
  • [8] A motion phantom system for image quality assessment of a 64-slice volume CT scanner
    So, J.
    Nickoloff, E.
    Lu, Z.
    Dutta, A.
    MEDICAL PHYSICS, 2007, 34 (06) : 2339 - 2339
  • [9] Pancreatic adenocarcinoma: dynamic 64-slice helical CT with perfusion imaging
    Xu, Jin
    Liang, Zonghui
    Hao, Sijie
    Zhu, Li
    Ashish, Maskay
    Jin, Chen
    Fu, Deliang
    Ni, Quanxing
    ABDOMINAL IMAGING, 2009, 34 (06): : 759 - 766
  • [10] Timing on 16-slice scanner and implications for 64-slice cardiac CT: Do you start scanning immediately after breath hold?
    Horiguchi, J
    Shen, Y
    Hirai, N
    Yamamoto, H
    Akiyama, Y
    Ishifuro, M
    Kakizawa, H
    Hieda, M
    Tachikake, T
    Matsuura, N
    Ito, K
    ACADEMIC RADIOLOGY, 2006, 13 (02) : 173 - 176