Kinect V2-Based Gait Analysis for Children with Cerebral Palsy: Validity and Reliability of Spatial Margin of Stability and Spatiotemporal Variables

被引:14
|
作者
Ma, Yunru [1 ]
Mithraratne, Kumar [2 ]
Wilson, Nichola [3 ]
Zhang, Yanxin [1 ]
Wang, Xiangbin [4 ,5 ]
机构
[1] Univ Auckland, Dept Exercise Sci, Auckland 1142, New Zealand
[2] Univ Auckland, Auckland Bioengn Inst, Auckland 1142, New Zealand
[3] Univ Auckland, Dept Surg, Auckland 1142, New Zealand
[4] Fujian Univ Tradit Chinese Med, Coll Rehabil Med, Fuzhou 350122, Peoples R China
[5] Fujian Univ Tradit Chinese Med, Key Lab Orthoped & Traumatol Tradit Chinese Med &, Minist Educ, Fuzhou 350122, Peoples R China
基金
中国国家自然科学基金;
关键词
cerebral palsy; spatiotemporal; margin of stability; reliability; validity; Kinect V2; TEST-RETEST RELIABILITY; MICROSOFT KINECT; CONCURRENT VALIDITY; POSTURAL BALANCE; POSE TRACKING; PARAMETERS; TREADMILL; WALKING; SYSTEM; FALLS;
D O I
10.3390/s21062104
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Children with cerebral palsy (CP) have high risks of falling. It is necessary to evaluate gait stability for children with CP. In comparison to traditional motion capture techniques, the Kinect has the potential to be utilised as a cost-effective gait stability assessment tool, ensuring frequent and uninterrupted gait monitoring. To evaluate the validity and reliability of this measurement, in this study, ten children with CP performed two testing sessions, of which gait data were recorded by a Kinect V2 sensor and a referential Motion Analysis system. The margin of stability (MOS) and gait spatiotemporal metrics were examined. For the spatiotemporal parameters, intraclass correlation coefficient (ICC2,k) values were from 0.83 to 0.99 between two devices and from 0.78 to 0.88 between two testing sessions. For the MOS outcomes, ICC2,k values ranged from 0.42 to 0.99 between two devices and 0.28 to 0.69 between two test sessions. The Kinect V2 was able to provide valid and reliable spatiotemporal gait parameters, and it could also offer accurate outcome measures for the minimum MOS. The reliability of the Kinect V2 when assessing time-specific MOS variables was limited. The Kinect V2 shows the potential to be used as a cost-effective tool for CP gait stability assessment.
引用
收藏
页码:1 / 17
页数:15
相关论文
共 45 条
  • [41] Spatial-temporal analysis and clinical gait findings: comparison of two treatment modalities treatment in children with cerebral palsy-spastic hemiplegia. Preliminary report
    Tamara Arellano-Martinez, Irma
    Rodriguez-Reyes, Gerardo
    Quinones-Uriostegui, Ivet
    Elena Arellano-Saldana, Maria
    [J]. CIRUGIA Y CIRUJANOS, 2013, 81 (01): : 14 - 20
  • [42] Usability and Reliability of the Edinburgh Visual Gait Score in Children with Spastic Cerebral Palsy Using Smartphone Slow-Motion Video Technology and a Motion Analysis Application: A Pilot Study
    Aroojis, Alaric
    Sagade, Bhushan
    Chand, Suresh
    [J]. INDIAN JOURNAL OF ORTHOPAEDICS, 2021, 55 (04) : 931 - 938
  • [43] Usability and Reliability of the Edinburgh Visual Gait Score in Children with Spastic Cerebral Palsy Using Smartphone Slow-Motion Video Technology and a Motion Analysis Application: A Pilot Study
    Alaric Aroojis
    Bhushan Sagade
    Suresh Chand
    [J]. Indian Journal of Orthopaedics, 2021, 55 : 931 - 938
  • [44] Validity and reliability of the Turkish version of the pediatric motor activity log-revised (PMAL-R) for 2-17 year old children with hemiparetic cerebral palsy
    Gunel, Mintaze Kerem
    Seyhan, Kubra
    Delioglu, Kivanc
    Dogan, Tuba Derya
    Altunalan, Turgay
    Kala, Yasemin
    Taub, Edward
    Uswatte, Gitendra
    [J]. DISABILITY AND REHABILITATION, 2022, 44 (15) : 4047 - 4054