A theoretical framework for filtered backprojection in tomosynthesis

被引:130
|
作者
Lauritsch, G [1 ]
Harer, WH [1 ]
机构
[1] Siemens AG, Med Engn Grp, Erlangen, Germany
关键词
reconstruction; 3D-imaging; limited angle tomography; tomosynthesis; filtered backprojection; ectomography; transfer function; dentistry; filter design; classical tomography;
D O I
10.1117/12.310839
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tomosynthesis provides only incomplete 3D-data of the imaged object. Therefore it is important for reconstruction tasks to take all available information carefully into account. We are focusing on geometrical aspects of the scan process which can be incorporated into reconstruction algorithms by filtered backprojection methods. Our goal is a systematic approach to filter design. A unified theory of tomosynthesis is derived in the context of linear system theory, and a general four-step filter design concept is presented. Since the effects of filtering are understandable in this context, a methodical formulation of filter functions is possible in order to optimize image quality regarding the specific requirements of any application. By variation of filter parameters the slice thickness and the spatial resolution can easily be adjusted. The proposed general concept of filter design is exemplarily discussed for circular scanning but is valid for any specific scan geometry. The inherent limitations of tomosynthesis are pointed out and strategies for reducing the effects of incomplete sampling are developed. Results of a dental application show a striking improvement in image quality.
引用
收藏
页码:1127 / 1137
页数:11
相关论文
共 50 条
  • [1] Filtered backprojection for modifying the impulse response of circular tomosynthesis
    Stevens, GM
    Fahrig, R
    Pelc, NJ
    [J]. MEDICAL PHYSICS, 2001, 28 (03) : 372 - 380
  • [2] Generalized Filtered Backprojection for Digital Breast Tomosynthesis Reconstruction
    Erhard, Klaus
    Grass, Michael
    Hitziger, Sebastian
    Iske, Armin
    Nielsen, Tim
    [J]. MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [3] Filtered-backprojection for improved blurring in circular tomosynthesis
    Stevens, GM
    Fahrig, R
    Pelc, NJ
    [J]. RADIOLOGY, 2000, 217 : 314 - 315
  • [4] A novel approach for filtered backprojection in tomosynthesis based on filter kernels determined by iterative reconstruction techniques
    Ludwig, Jasmina
    Mertelmeier, Thomas
    Kunze, Holger
    Haerer, Wolfgang
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 612 - 620
  • [5] Reflective filtered backprojection
    Bellet, Jean-Baptiste
    Berginc, Gerard
    [J]. COMPTES RENDUS MATHEMATIQUE, 2016, 354 (09) : 960 - 964
  • [6] 3-d view weighted cone-beam filtered backprojection reconstruction for digital tomosynthesis
    Li, Baojun
    Avinash, Gopal
    Claus, Bernhard
    Metz, Stephen
    [J]. MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [7] Adaptation of image quality using various filter setups in the filtered backprojection approach for digital breast tomosynthesis
    Orman, Jasmina
    Mertelmeier, Thomas
    Haerer, Wolfgang
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2006, 4046 : 175 - 182
  • [8] ON THE OPTIMALITY OF THE FILTERED BACKPROJECTION ALGORITHM
    HANSON, KM
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (03) : 361 - 363
  • [9] Optimizing filtered backprojection reconstruction for a breast tomosynthesis prototype device - art. no. 61420F
    Mertelmeier, Thomas
    Orman, Jasmina
    Haerer, Wolfgang
    Dudam, Mithun K.
    [J]. Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 : F1420 - F1420
  • [10] Filtered backprojection implementation of the immediately-after-backprojection filtering
    Zeng, Gengsheng L.
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (04):