The St. Jude medical cardiac valve prosthesis: Long-term follow up of patients having double valve replacement

被引:0
|
作者
Emery, Robert W. [1 ]
Emery, Ann M. [1 ]
Krogh, Christopher [1 ]
Shake, Jay G. [1 ]
Holter, Arlen R. [1 ]
Blake, David P. [1 ]
Raikar, Goya V. [1 ]
机构
[1] Cardiac Surg Associates, St Paul, MN USA
来源
JOURNAL OF HEART VALVE DISEASE | 2007年 / 16卷 / 06期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: Between October 1977 and February 2002, a total of 343 patients (mean age 62 13 years; range: 19-91 years) underwent double valve replacement (DVR) with the St. Jude Medical (SJM) heart valve. Among the replacements, 337 (98%) were aortic and mitral in nature. Concomitant coronary artery bypass was performed in 73 patients (21%). Methods: Cardiac Surgical Associates has maintained an independent database of patients undergoing valve replacement with the SJM prosthesis since the valve's first implantation in October 1977. Patients were contacted by questionnaire and/or telephone (94% complete) between November 2002 and June 2003. The patients' hospital course and valve-related events were verified by patient chart review and/or physician contact. Results: Operative mortality was 8% (n = 29); mortality was valve-related in two cases. The mean follow up was 6.5 +/- 6.0 years (range: 1 month to 24 years); total follow up was 2,226 patient-years. Over 25 years, patient freedom from late mortality was 62%, and from valve-related mortality 78%. Freedom from thromboembolic events was 82% (93% from permanent defect), from bleeding events 76%, from endocarditis 98%, from valve thrombosis 99.9%, and from reoperation 98%. Six reoperations were carried out in five patients (2%), valve repair or replacement in five (2%), and suture closure of paravalvular leak in one patient (0.3%). There were no valve structural failures reported. Conclusion: The SJM valve has proven to be an effective and durable heart valve prosthesis. Over the long term, the event rate is low and there is excellent freedom from reoperation in the double valve configuration.
引用
收藏
页码:634 / 640
页数:7
相关论文
共 50 条
  • [1] Reoperative valve replacement with the St. Jude Medical valve prosthesis: Long-term follow-up
    Emery, RW
    Arom, KV
    Krogh, C
    Joyce, LD
    Nicoloff, D
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 438A - 438A
  • [2] Long-term experience with the St. Jude Medical valve prosthesis
    Zellner, JL
    Kratz, JM
    Crumbley, AJ
    Stroud, MR
    Bradley, SM
    Sade, RM
    Crawford, FA
    ANNALS OF THORACIC SURGERY, 1999, 68 (04): : 1210 - 1218
  • [3] Replacement of the aortic valve in patients under 50 years of age: Long-term follow-up of the St. Jude Medical prosthesis
    Emery, RW
    Erickson, CA
    Arom, KV
    Northrup, WF
    Kersten, TE
    Von Rueden, TJ
    Lillehei, TJ
    Nicoloff, DM
    ANNALS OF THORACIC SURGERY, 2003, 75 (06): : 1815 - 1819
  • [4] Long-Term Follow Up of Patients Undergoing Reoperative Surgery with Aortic or Mitral Valve Replacement Using a St. Jude Medical Prosthesis
    Emery, Robert W.
    Krogh, Christopher C.
    McAdams, Sean
    Emery, Ann M.
    Holter, Arlen R.
    JOURNAL OF HEART VALVE DISEASE, 2010, 19 (04): : 473 - 484
  • [5] Bileaflet mechanical valve (St. Jude Medical valve) replacement in long-term dialysis patients
    Ura, M
    Sakata, R
    Nakayama, Y
    Fukui, H
    ANNALS OF THORACIC SURGERY, 1999, 68 (03): : 870 - 873
  • [6] Long-term experience with the St. Jude Medical valve prosthesis - Discussion
    Arom, KV
    Zellner
    Ungerleider, RM
    ANNALS OF THORACIC SURGERY, 1999, 68 (04): : 1218 - 1218
  • [7] EXCELLENT LONG-TERM RESULTS OF CARDIAC-VALVE REPLACEMENT WITH THE ST-JUDE MEDICAL VALVE PROSTHESIS
    SMITH, JA
    WESTLAKE, GW
    MULLERWORTH, MH
    SKILLINGTON, PD
    TATOULIS, J
    CIRCULATION, 1993, 88 (05) : 49 - 54
  • [8] EXCELLENT LONG-TERM RESULTS OF CARDIAC-VALVE REPLACEMENT WITH THE ST-JUDE MEDICAL VALVE PROSTHESIS
    SMITH, JA
    WESTLAKE, GW
    MULLERWORTH, MH
    SKILLINGTON, PD
    TATOULIS, J
    CIRCULATION, 1992, 86 (04) : 699 - 699
  • [9] Long-term results of aortic valve replacement with a small St. Jude Medical Valve in Japanese patients
    Yoshikawa, Kazuhiro
    Fukunaga, Shuji
    Arinaga, Koichi
    Hori, Hidetsugu
    Nakamura, Eiji
    Ueda, Tomohiro
    Tayama, Eiki
    Aoyagi, Shigeaki
    ANNALS OF THORACIC SURGERY, 2008, 85 (04): : 1303 - 1309
  • [10] LONG-TERM RESULTS OF VALVE-REPLACEMENT WITH THE ST-JUDE MEDICAL PROSTHESIS
    BAUDET, EM
    PUEL, V
    MCBRIDE, JT
    GRIMAUD, JP
    ROQUES, F
    CLERC, F
    ROQUES, X
    LABORDE, N
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 109 (05): : 858 - 870