Measurement of Lubricant Film Thickness Using Spectral Domain Optical Coherence Tomography (SD-OCT)

被引:0
|
作者
Qin, Y-W. [1 ,2 ]
Zhao, H. [1 ]
Zhang, L. [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Mfg Syst Engn, Xian 710049, Peoples R China
[2] Weinan Normal Univ, Sch Phys & Elect Engn, Weinan 714000, Peoples R China
基金
中国博士后科学基金;
关键词
Laser; lubricant; flint thickness; optical coherence tomography (OCT); spectral domain optical coherence tomography (SD-OCT); cross-sectional image; IN-VIVO;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A thermal-light source spectral domain optical coherence tomography (SD-OCT) was introduced to measure lubricant film thickness. An efficient interference spectrum decoupling algorithm was used to improve the signal-to-noise ratio and image contrast by eliminating both the direct current (DC) and the autocorrelation noise. Then high quality one-dimensional (1-D) depth and two-dimensional (2-D) image of the film were obtained with the proposed method. The film thickness was measured from the obtained image. It was experimentally demonstrated that this method can achieve the accurate measurement of lubricant film thickness.
引用
收藏
页码:129 / 139
页数:11
相关论文
共 50 条
  • [11] Differentiation of Underlying Pathologies of Macular Edema Using Spectral Domain Optical Coherence Tomography (SD-OCT)
    Dysli, Muriel
    Ruckert, Rene
    Munk, Marion R.
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2019, 27 (03) : 474 - 483
  • [12] Epiretinal membrane as a source of errors during the measurement of peripapillary nerve fibre thickness using spectral-domain optical coherence tomography (SD-OCT)
    Ruefer, Florian
    Bartsch, Julia Jasmin
    Erb, Carl
    Riehl, Anneliese
    Zeitz, Philipp Franko
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (10) : 2017 - 2023
  • [13] Epiretinal membrane as a source of errors during the measurement of peripapillary nerve fibre thickness using spectral-domain optical coherence tomography (SD-OCT)
    Florian Rüfer
    Julia Jasmin Bartsch
    Carl Erb
    Anneliese Riehl
    Philipp Franko Zeitz
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2016, 254 : 2017 - 2023
  • [14] En-face spectral domain optical coherence tomography (SD-OCT) of the corneoscleral limbus
    Wajdene, Ghouali
    Hassani, Rachid Tahiri Joutei
    Liang, Hong
    Djerada, Zoubir
    El Sanharawi, Mohamed
    Labbe, Antoine
    Baudouin, Christophe
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [15] Spectral Domain Optical Coherence Tomography (SD-OCT) in Surgery for Optic Disc Pit Maculopathy
    Stoffelns, B. M.
    Laspas, P.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2016, 233 (04) : 505 - 507
  • [16] Spectral domain - Optical coherence tomography (SD-OCT) as a monitoring tool for alterations in mouse lenses
    Pawliczek, Daniel
    Dalke, Claudia
    Fuchs, Helmut
    Gailus-Durner, Valerie
    de Angelis, Martin Hrabe
    Graw, Jochen
    Amarie, Oana Veronica
    EXPERIMENTAL EYE RESEARCH, 2020, 190
  • [17] Macular thickness measurements of healthy, naive cynomolgus monkeys assessed with spectral-domain optical coherence tomography (SD-OCT)
    Denk, Nora
    Maloca, Peter
    Steiner, Guido
    Freichel, Christian
    Bassett, Simon
    Schnitzer, Tobias K.
    Hasler, Pascal W.
    PLOS ONE, 2019, 14 (10):
  • [18] Effect of Age on Healthy Retinal Nerve Fiber Layer Thickness Measurements Using Spectral-Domain Optical Coherence Tomography (SD-OCT)
    Layer, N.
    Soliman, A.
    Wu, H.
    De Boer, J. F.
    Chen, T. C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [19] Impact of segmentation density on spectral domain optical coherence tomography (SD-OCT) assessments in Stargardt disease
    Jha, Anamika
    Ho, Alexander
    Nittala, Muneeswar Gupta
    Strauss, Rupert Wolfgang
    Scholl, Hendrik P.
    Sadda, Srinivas R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [20] Glaucoma discrimination of segmented cirrus spectral domain optical coherence tomography (SD-OCT) macular scans
    Kotowski, Jacek
    Folio, Lindsey S.
    Wollstein, Gadi
    Ishikawa, Hiroshi
    Ling, Yun
    Bilonick, Richard A.
    Kagemann, Larry
    Schuman, Joel S.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (11) : 1420 - 1425