Composite removal by means of erbium, chromium:yttrium-scandium-gallium-garnet laser compared with rotary instruments

被引:2
|
作者
Tantbirojn, Daranee [1 ]
Walinski, Christopher J. [1 ,2 ]
Ross, Judith A. [1 ]
Taylor, Charlotte R. [1 ]
Versluis, Antheunis [3 ]
机构
[1] Univ Tennessee, Coll Dent, Dept Gen Dent, Hlth Sci Ctr, 875 Union Ave, Memphis, TN 38163 USA
[2] Touro Coll Dent Med, Hawthorne, NY USA
[3] Univ Tennessee, Ctr Hlth Sci, Dept Biosci Res, Coll Dent, Memphis, TN 38163 USA
来源
关键词
Bur; composite; laser; restoration removal; tooth structure; BOND STRENGTH; TOOTH SURFACES; RESTORATIONS; ADHESIVE; ABLATION; REPLACEMENT; SURVIVAL; REPAIR; DENTIN;
D O I
10.1016/j.adaj.2019.07.033
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background. Complete removal of existing composite restorations without unnecessary removal of tooth structure is challenging. The authors compared the amount of tooth structure removed and composite remaining in Class III preparations when using an erbium laser or a rotary instrument. Methods. Mesiolingual and distolingual preparations were prepared in 14 extracted anterior teeth, restored with shade-matched composite, finished, and polished. One restoration was removed with an erbium, chromium:yttrium-scandium-gallium-garnet laser and the other with a rotary instrument (handpiece and carbide burs). Gypsum models made from vinyl polysiloxane impressions of the preparation and removal stages were scanned. The 2 scans were precisely aligned to calculate the amount of tooth structure removed and residual composite, which were statistically compared (t test) between the bur and laser groups. Results. Rotary instruments removed significantly more tooth structure than the laser in terms of mean depth (P = .0017) but not maximum depth (P = .0762). Although mean depth of tooth loss was smaller in the laser group, the area of tooth loss was significantly larger (P = .0004) because the rotary instrumentation left significantly more composite than the laser in terms of volume (P = .0104), mean depth (P = .0375), maximum depth (P = .0318), and area (P = .0056). Conclusions and Practical Implications. The erbium, chromium:yttrium-scandium-galliumgarnet laser was more selective in removing existing composite restorations than a rotary instrument because it removed less tooth structure and left behind less composite. Unintentional loss of tooth structure and unnoticeable residual composite are inevitable when removing existing composites. Erbium lasers are alternative means of composite removal that may be more selective than a rotary instrument.
引用
收藏
页码:1040 / 1047
页数:8
相关论文
共 50 条
  • [41] Measurement of pressure changes during laser-activated irrigant by an erbium, chromium: yttrium, scandium, gallium, garnet laser
    Harry Huiz Peeters
    Roeland J. G. De Moor
    Lasers in Medical Science, 2015, 30 : 1449 - 1455
  • [42] Measurement of pressure changes during laser-activated irrigant by an erbium, chromium: yttrium, scandium, gallium, garnet laser
    Peeters, Harry Huiz
    De Moor, Roeland J. G.
    LASERS IN MEDICAL SCIENCE, 2015, 30 (05) : 1449 - 1455
  • [43] The use of the erbium, chromium:yttrium -: scandium-gallium-garnet laser in endodontic treatment -: The results of an in vitro study
    Schoop, Ulrich
    Goharkhay, Kawe
    Klimscha, Johannes
    Zagler, Manuela
    Wernisch, Johann
    Georgopoulos, Apostolos
    Sperr, Wolfgang
    Moritz, Andreas
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2007, 138 (07): : 949 - 955
  • [44] Clinical and Biochemical Effects of Erbium, Chromium: Yttrium, Scandium, Gallium, Garnet Laser Treatment as a Complement to Periodontal Treatment
    Ustun, K.
    Hatipoglu, M.
    Daltaban, O.
    Felek, R.
    Firat, M. Z.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2018, 21 (09) : 1150 - 1157
  • [45] Visualising the procedures in the influence of water on the ablation of dental hard tissue with erbium:yttrium–aluminium–garnet and erbium, chromium:yttrium–scandium–gallium-garnet laser pulses
    Maziar Mir
    Norbert Gutknecht
    Reinhart Poprawe
    Leon Vanweersch
    Friedrich Lampert
    Lasers in Medical Science, 2009, 24 : 365 - 374
  • [46] Cystic lesions associated with rhinophyma treated with an ablative fractional yttrium-scandium-gallium-garnet laser
    Alcantara Gonzalez, Javier
    Boixeda, Pablo
    Truchuelo Diez, Maria Teresa
    Allende Markixana, Irati
    Jaen, Pedro
    JOURNAL OF COSMETIC AND LASER THERAPY, 2010, 12 (06) : 261 - 263
  • [47] Evaluation of microtensile and tensile bond strength tests determining effects of erbium, chromium: yttrium-scandium-gallium-garnet laser pulse frequency on resin-enamel bonding
    Yildirim, T.
    Ayar, M. K.
    Yesilyurt, C.
    Kilic, S.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2016, 19 (05) : 585 - 590
  • [48] The effects of using erbium, chromium-doped:yttrium-scandium-gallium-garnet laser on the surface modification, bacterial decontamination, and cell adhesion on zirconia discs: an in vitro study
    Pham, Charles M.
    Chen, Chia-Yu
    Kim, David M.
    LASERS IN MEDICAL SCIENCE, 2021, 36 (08) : 1701 - 1708
  • [49] Comparison of Bacterial Reduction in Straight and Curved Canals Using Erbium, Chromium:Yttrium-Scandium-Gallium-Garnet Laser Treatment versus a Traditional Irrigation Technique With Sodium Hypochlorite
    Dewsnup, Nathan
    Pileggi, Roberta
    Haddix, James
    Nair, Uma
    Walker, Clay
    Varella, Claudio Herdy
    JOURNAL OF ENDODONTICS, 2010, 36 (04) : 725 - 728
  • [50] The effects of using erbium, chromium-doped:yttrium-scandium-gallium-garnet laser on the surface modification, bacterial decontamination, and cell adhesion on zirconia discs: an in vitro study
    Charles M. Pham
    Chia-Yu Chen
    David M. Kim
    Lasers in Medical Science, 2021, 36 : 1701 - 1708