CT sinogram-consistency learning for metal-induced beam hardening correction

被引:84
|
作者
Park, Hyoung Suk [1 ]
Lee, Sung Min [2 ]
Kim, Hwa Pyung [2 ]
Seo, Jin Keun [2 ]
Chung, Yong Eun [3 ]
机构
[1] Natl Inst Math Sci, Div Integrated Math, Daejeon 34047, South Korea
[2] Yonsei Univ, Dept Computat Sci & Engn, Seoul 120749, South Korea
[3] Yonsei Univ, Coll Med, Dept Radiol, Seoul 03722, South Korea
基金
新加坡国家研究基金会;
关键词
computerized tomography; deep learning; metal artifact reduction; tomographic image reconstruction; ARTIFACTS; REDUCTION;
D O I
10.1002/mp.13199
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose This paper proposes a sinogram-consistency learning method to deal with beam hardening-related artifacts in polychromatic computerized tomography (CT). The presence of highly attenuating materials in the scan field causes an inconsistent sinogram that does not match the range space of the Radon transform. When the mismatched data are entered into the range space during CT reconstruction, streaking and shading artifacts are generated owing to the inherent nature of the inverse Radon transform Methods The proposed learning method aims to repair inconsistent sinogram by removing the primary metal-induced beam hardening factors along the metal trace in the sinogram. Taking account of the fundamental difficulty in obtaining sufficient training data in a medical environment, the learning method is designed to use simulated training data and a patient's implant type-specific learning model is used to simplify the learning process. Results The feasibility of the proposed method is investigated using a dataset, consisting of real CT scans of pelvises containing simulated hip prostheses. The anatomical areas in training and test data are different, in order to demonstrate that the proposed method extracts the beam hardening features, selectively. The results show that our method successfully corrects sinogram inconsistency by extracting beam hardening sources by means of deep learning. Conclusion This paper proposed a deep learning method of sinogram correction for beam hardening reduction in CT for the first time. Conventional methods for beam hardening reduction are based on regularizations, and have the fundamental drawback of being not easily able to use manifold CT images, while a deep learning approach has the potential to do so.
引用
收藏
页码:5376 / 5384
页数:9
相关论文
共 50 条
  • [1] Beam-hardening correction method based on original sinogram for X-CT
    Fu, J
    Lu, HN
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 556 (01): : 379 - 385
  • [2] Sinogram domain metal artifact correction of CT via deep learning
    Zhu, Yulin
    Zhao, Hanqing
    Wang, Tangsheng
    Deng, Lei
    Yang, Yupeng
    Jiang, Yuming
    Li, Na
    Chan, Yinping
    Dai, Jingjing
    Zhang, Chulong
    Li, Yunhui
    Xie, Yaoqin
    Liang, Xiaokun
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2023, 155
  • [3] Technical Note: A model-based sinogram correction for beam hardening artifact reduction in CT
    Lee, Sung Min
    Seo, Jin Keun
    Chung, Yong Eun
    Baek, Jongduk
    Park, Hyoung Suk
    [J]. MEDICAL PHYSICS, 2017, 44 (09) : E147 - E152
  • [4] A Direct Sinogram Correction Method to Reduce Metal-Related Beam-Hardening in Computed Tomography
    Lee, Sung Min
    Bayaraa, Taigyntuya
    Jeong, Hosan
    Hyun, Chang Min
    Seo, Jin Keun
    [J]. IEEE ACCESS, 2019, 7 : 128828 - 128836
  • [5] Reduction of beam hardening induced metal artifacts using consistency conditions
    Abdurahman, Shiras
    Frysch, Robert
    Rose, Georg
    [J]. 15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [6] Beam Hardening Correction Using Cone Beam Consistency Conditions
    Abdurahman, Shiras
    Frysch, Robert
    Bismark, Richard
    Melnik, Steffen
    Beuing, Oliver
    Rose, Georg
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (10) : 2266 - 2277
  • [7] Metal Artifact Reduction Based on Sinogram Correction in CT
    Jeong, Kye Young
    Ra, Jong Beom
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3480 - 3483
  • [8] A beam hardening correction method based on HL Consistency
    Mou, Xuanqin
    Tang, Shaojie
    Yu, Hengyong
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [9] A sinogram based technique for image correction and removal of metal clip artifacts in cone beam breast CT
    Wang, T.
    Shen, Y.
    Zhong, Y.
    Lai, C. -J.
    Wang, J.
    Shaw, C. C.
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [10] Iterative correction of beam hardening artifacts in CT
    Van Gompel, G.
    Van Slambrouck, K.
    Defrise, M.
    Batenburg, K. J.
    de Mey, J.
    Sijbers, J.
    Nuyts, J.