A Strategic and Significant Method for the Optimal Placement of Phasor Measurement Unit for Power System Network

被引:7
|
作者
Baba, Maveeya [1 ]
Nor, Nursyarizal B. M. [1 ]
Sheikh, M. Aman [2 ]
Irfan, Muhammad [3 ]
Tahir, Mohammad [2 ]
机构
[1] Univ Teknol Petronas, Dept Elect & Elect Engn, Tronoh 32610, Perak, Malaysia
[2] Sunway Univ, Dept Comp & Informat Syst, Bandar Sunway,Petaling Jaya 47500, Petaling Jaya 47500, Selangor, Malaysia
[3] Najran Univ, Coll Engn, Elect Engn Dept, Najran 1988, Saudi Arabia
来源
SYMMETRY-BASEL | 2020年 / 12卷 / 07期
关键词
channel limits; optimal PMU placement problem (OPPP); phasor measurement units (PMUs); PMUs outage; zero injection buses (ZIBs); OPTIMAL PMU PLACEMENT; BINARY PSO ALGORITHM; OBSERVABILITY;
D O I
10.3390/sym12071174
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Currently the new state of power system relies on a precise monitoring of electrical quantities such as voltage and current phasors. Occasionally, its operation gets disturbed because of the flicking in load and generation which may result in the interruption of power supply or may cause catastrophic failure. The advanced technology of phasor measurement unit (PMU) is introduced in the late 1990s to measure the behavior of power system more symmetrically, accurately, and precisely. However, the implementation of this device at every busbar in a grid station is not an easy task because of its expensive installation and manufacturing cost. As a result, an optimum placement of PMU is much needed in this case. Therefore, this paper proposes a new symmetry approach of multiple objectives for the optimum placement of PMU problem (OPPP) in order to minimize the installed number of PMUs and maximize the measurement redundancy of the network. To overcome the drawbacks of traditional techniques in the proposed work a reduction and exclusion of pure transit node technique is used in the placement set. In which only the strategic, significant, and the most desirable buses are selected without considering zero injection buses (ZIBs). The fundamental novelty of the proposed work considers most importantly the reduction technique of ZIBs from the optimum PMU locations, as far as the prior approaches concern almost every algorithm have taken ZIBs as their optimal placement sets. Furthermore, a PMUs channel limits and an alternative symmetry location for the PMUs placement are considered when there is an outage or PMUs failure may occur. The performance of the proposed method is verified on different IEEE-standard such as: IEEE-9, IEEE-14, IEEE-24, IEEE-30, IEEE-57, IEEE-118, and a New England-39 bus system. The success of the proposed work was compared with the existing techniques' outcomes from the literature.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] A Hierarchical Analysis of Phasor Measurement Unit Placement Optimization in Transmission Network
    Zhong, Jiangxia
    Wong, K. L.
    [J]. 2011 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2011,
  • [32] System Redundancy Index based Optimized Phasor Measurement Unit Placement for Complete Network Observability
    Awon, Muhammad
    Butt, Hassan Zahid
    Khalid, Hassan Abdullah
    Janjua, Abdul Kashif
    [J]. 2018 4TH INTERNATIONAL CONFERENCE ON POWER GENERATION SYSTEMS AND RENEWABLE ENERGY TECHNOLOGIES (PGSRET-2018), 2018, : 181 - 185
  • [33] Optimization of Phasor Measurement Unit Placement Using Several Proposed Case Factors for Power Network Monitoring
    Baba, Maveeya
    Nor, Nursyarizal B. M.
    Sheikh, Muhammad Aman
    Baba, Abdul Momin
    Irfan, Muhammad
    Glowacz, Adam
    Kozik, Jaroslaw
    Kumar, Anil
    [J]. ENERGIES, 2021, 14 (18)
  • [34] Optimal phasor measurement units placement considering multi-objectives in shipboard power system
    [J]. Wang, J. (wang0600519@sina.com), 1600, Science Press (38):
  • [35] A Multi-criteria Optimal Phasor Measurement Unit Placement for Multiple Applications
    Fadiran, J. I.
    Chowdhury, S.
    Chowdhury, S. P.
    [J]. 2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [36] Algorithm of optimal phasor measurement unit placement considering multi-constraints
    Chen X.-G.
    Yu H.
    Wang B.
    Jiang Z.-W.
    Jiang Q.-Y.
    Guo C.-X.
    Cao Y.-J.
    [J]. Zhejiang Daxue Xuebao(Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2010, 44 (03): : 539 - 543
  • [37] Optimal Placement of Phasor Measurement Unit in Smart Grids Considering Multiple Constraints
    Chen, Tengpeng
    Ren, He
    Sun, Yuhao
    Kraft, Markus
    Amaratunga, Gehan A. J.
    [J]. JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2023, 11 (02) : 479 - 488
  • [38] Optimal placement of phasor measurement unit in distribution networks considering the changes in topology
    Su, Hongzhi
    Wang, Chengshan
    Li, Peng
    Liu, Zhelin
    Yu, Li
    Wu, Jianzhong
    [J]. APPLIED ENERGY, 2019, 250 : 313 - 322
  • [39] Optimal Placement of Phasor Measurement Unit in Smart Grids Considering Multiple Constraints
    Tengpeng Chen
    He Ren
    Yuhao Sun
    Markus Kraft
    Gehan A.J.Amaratunga
    [J]. Journal of Modern Power Systems and Clean Energy, 2023, 11 (02) : 479 - 488
  • [40] Globally optimal phasor measurement unit placement using branch and bound algorithm
    Kamh, Mohamed Z.
    Younis, Mohamed R.
    Ibrahim, Amr M.
    [J]. AIN SHAMS ENGINEERING JOURNAL, 2021, 12 (03) : 2789 - 2798