Quantifying chlorine-reactive substances to establish a chlorine decay model of reclaimed water using chemical chlorine demands

被引:25
|
作者
Wang Yun-Hong [1 ]
Wu Yin-Hu [1 ]
Du Ye [1 ]
Li Qing [1 ]
Cong Yi [1 ]
Huo Zheng-Yang [1 ]
Chen Zhuo [1 ,2 ]
Yang Hong-Wei [1 ]
Liu Shu-Ming [1 ]
Hu Hong-Ying [1 ,2 ]
机构
[1] Tsinghua Univ, Sch Environm, State Environm Protect Key Lab Microorganism Appl, Environm Simulat & Pollut Control State Key Joint, Beijing 100084, Peoples R China
[2] Tsinghua Berkeley Shenzhen Inst, Shenzhen Environm Sci & New Energy Technol Engn L, Shenzhen 518055, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Chlorine decay model; Reclaimed water; Chlorine demands; Residual chlorine; DISSOLVED ORGANIC-MATTER; DRINKING-WATER; BULK-DECAY; RECLAMATION; RESIDUALS; KINETICS; REUSE;
D O I
10.1016/j.cej.2018.09.091
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In order to guarantee the water quality of reclaimed water in pipeline system, a chlorine bulk-decay model is required for simulation and prediction of chlorine profiles in networks. Conventional chlorine decay models of drinking water are not applicable to reclaimed water due to its complex and varying water quality. In this study, the chlorine decay of reclaimed water was investigated under different operational conditions. Based on these results, different chlorine-reactive substances (CRSs) in reclaimed water were quantified by total chlorine demand (TCD), instantaneous chlorine demand (ICD) and lasting chlorine demand (LCD), respectively. A stoichiometric model (CRS model) of chlorine decay of reclaimed water was established using ICD, TCD and reaction rate constant (k) as key independent parameters. The experimental data were fitted to the CRS model with promising results under various initial chlorine concentrations (3-10 mg-Cl-2/L) and temperatures (8-35 degrees C). The ICD, TCD and k of different reclaimed water samples were in the range of 0.23 to 2.85 mg-Cl-2/L, 1.07 to 4.73 mg-Cl-2/L, and 0.04 to 4.06 L/(mg.h), respectively. Furthermore, the ICDs, TCDs and k could be determined directly by measuring the chlorine consumption at 5 min (Delta C-Cl,C-5min) and 8 h (Delta C-Cl,C-8h) after the addition of chlorine into reclaimed water, and the UV254 of reclaimed water, respectively. The relationships between ICD, TCD, k and the corresponding water quality indexes were further validated. In this way, the chlorine decay profile of reclaimed water could be predicted rapidly and precisely by measuring the Delta C-Cl,C-5min, Delta C-Cl,C-8h, and UV254 of reclaimed water.
引用
收藏
页码:791 / 798
页数:8
相关论文
共 50 条
  • [21] Multifactor interaction-based free chlorine decay model in bulk water
    Jiang, Hui
    Jiang, Wenchao
    Long, Tengrui
    Deng, Xiaoli
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2013, 41 (02): : 128 - 132
  • [23] Modeling of chlorine decay in drinking water supply systems using EPANET MSX
    Monteiro, L.
    Figueiredo, D.
    Dias, S.
    Freitas, R.
    Covas, D.
    Menaia, J.
    Coelho, S. T.
    12TH INTERNATIONAL CONFERENCE ON COMPUTING AND CONTROL FOR THE WATER INDUSTRY, CCWI2013, 2014, 70 : 1192 - 1200
  • [24] A study on evaluation of the pipe wall decay constants of residual chlorine and affecting factors in reclaimed water supply system
    Lee, H. D.
    Park, J. H.
    Kang, S. W.
    Kong, M. S.
    DESALINATION AND WATER TREATMENT, 2015, 53 (09) : 2378 - 2387
  • [25] Chlorine decay prediction in bulk water using the parallel second order model: An analytical solution development
    Kohpaei, Ahmad Jabari
    Sathasivan, Arumugam
    CHEMICAL ENGINEERING JOURNAL, 2011, 171 (01) : 232 - 241
  • [26] Using Bayesian statistics to estimate chlorine wall decay coefficients for water supply system
    Huang, Jinhui Jeanne
    McBean, Edward Arthur
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT-ASCE, 2008, 134 (02): : 129 - 137
  • [27] Simultaneous model of chlorine dosing and decay in drinking water distribution system and model predictive control application
    Muslim, Abrar
    Li, Qin
    Tade, Moses O.
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2008, 3 (06) : 613 - 621
  • [28] Decay kinetics model of available chlorine in slightly acidic electrolyzed water in storage and disinfection process
    He, Jinsong
    Qi, Fanyu
    Ye, Zhangying
    Yang, Nan
    Wei, Xiaoming
    Zhu, Songming
    Zhu, S. (zhusm@zju.edu.cn), 2013, Chinese Society of Agricultural Engineering (29): : 263 - 270
  • [29] Investigation into the relationship between chlorine decay and water distribution parameters using data driven methods
    Gibbs, M. S.
    Morgan, N.
    Maier, H. R.
    Dandy, G. C.
    Nixon, J. B.
    Holmes, M.
    MATHEMATICAL AND COMPUTER MODELLING, 2006, 44 (5-6) : 485 - 498
  • [30] Chlorine modeling in water distribution networks using ARX and ARMAX model structures
    Karadirek, I. Ethem
    Soyupak, Selcuk
    Muhammetoglu, Habib
    DESALINATION AND WATER TREATMENT, 2016, 57 (25) : 11592 - 11598