Disinfectant efficacy of chlorite and chlorine dioxide in drinking water biofilms

被引:124
|
作者
Gagnon, GA
Rand, JL
O'Leary, KC
Rygel, AC
Chauret, C
Andrews, RC
机构
[1] Dalhousie Univ, Dept Civil Engn, Halifax, NS B3J 2X4, Canada
[2] Cavanaugh Solut, Winston Salem, NC 27101 USA
[3] Indiana Univ Kokomo, Kokomo, IN 46904 USA
[4] Univ Toronto, Dept Civil Engn, Toronto, ON M1S 1A4, Canada
关键词
distribution system; chlorine dioxide; chlorite; biofilm; disinfection; heterotrophic bacteria;
D O I
10.1016/j.watres.2005.02.004
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The drinking water industry is closely examining options to maintain disinfection in distribution systems. In particular this research compared the relative efficiency of the chlorite ion (ClO2-) to chlorine dioxide (ClO2) for biofilm control. Chlorite levels were selected for monitoring since they are typically observed in the distribution system as a by-product whenever chlorine dioxide is applied for primary or secondary disinfection. Previous research has reported the chlorite ion to be effective in mitigating nitrification in distribution systems. Annular reactors (ARs) containing polycarbonate and cast iron coupons were used to simulate water quality conditions in a distribution system. Following a 4 week acclimation period, individual ARs operated in parallel were dosed with high (0.25 mg/l) and low (0.1 mg/l) chlorite concentrations and with high (0.5 mg/l) and low (0.25 mg/l) chlorine dioxide concentrations, as measured in the effluent of the AR. Another set of ARs that contained cast iron and polycarbonate coupons served as controls and did not receive any disinfection. The data presented herein show that the presence of chlorite at low concentration levels was not effective at reducing heterotrophic bacteria. Log reductions of attached heterotrophic bacteria for low and high chlorite ranged between 0.20 and 0.34. Chlorine dioxide had greater log reductions for attached heterotrophic bacteria ranging from 0.52 to 1.36 at the higher dose. The greatest log reduction in suspended heterotrophic bacteria was for high dose Of ClO2 on either cast iron or polycarbonate coupons (1.77 and 1.55). These data indicate that it would be necessary to maintain a chlorine dioxide residual concentration in distribution systems for control of microbiological regrowth. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1809 / 1817
页数:9
相关论文
共 50 条
  • [41] PREOXIDATION AND INTERMEDIATE OXIDATION OF DRINKING-WATER WITH OZONE, CHLORINE AND CHLORINE DIOXIDE
    SCHALEKAMP, M
    [J]. OZONE-SCIENCE & ENGINEERING, 1986, 8 (02) : 151 - 186
  • [42] POTENTIAL HEALTH EFFECTS OF CHLORINE DIOXIDE AS A DISINFECTANT IN POTABLE WATER-SUPPLIES
    MOORE, GS
    CALABRESE, EJ
    DINARDI, SR
    TUTHILL, RW
    [J]. MEDICAL HYPOTHESES, 1978, 4 (05) : 481 - 496
  • [43] CHLORITE AND CHLORINE DIOXIDE REMOVAL BY ACTIVATED CARBON
    VELLEITNER, NK
    DELAAT, J
    DORE, M
    SUTY, H
    POUILLOT, M
    [J]. WATER RESEARCH, 1992, 26 (08) : 1053 - 1066
  • [44] TOXICOLOGICAL EFFECTS OF CHLORINE DIOXIDE, CHLORITE AND CHLORATE
    COURI, D
    ABDELRAHMAN, MS
    BULL, RJ
    [J]. ENVIRONMENTAL HEALTH PERSPECTIVES, 1982, 46 (DEC) : 13 - 17
  • [45] THE INFLUENCE OF AN OZONE, CHLORINE AND CHLORINE DIOXIDE TREATMENT ON MUTAGENIC ACTIVITY IN (DRINKING) WATER
    KOOL, HJ
    HRUBEC, J
    [J]. OZONE-SCIENCE & ENGINEERING, 1986, 8 (03) : 217 - 234
  • [46] THE EFFECT OF CHLORINE AND CHLORINE DIOXIDE ON MICROBIAL-POPULATIONS IN DRINKING-WATER
    ROUF, MA
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 210 : 165 - ENVR
  • [47] Disinfection by-products in drinking water: A comparison between chlorine and chlorine dioxide
    Aggazzotti, G.
    Fantuzzi, G.
    Righi, E.
    Predieri, G.
    Giacobazzi, P.
    [J]. EPIDEMIOLOGY, 2007, 18 (05) : S61 - S61
  • [48] Formation of natural biofilms during chlorine dioxide and u.v. disinfection in a public drinking water distribution system
    Schwartz, T
    Hoffmann, S
    Obst, U
    [J]. JOURNAL OF APPLIED MICROBIOLOGY, 2003, 95 (03) : 591 - 601
  • [49] Determinants of disinfectant pretreatment efficacy for nitrosamine control in chloraminated drinking water
    McCurry, Daniel L.
    Krasner, Stuart W.
    von Gunten, Urs
    Mitch, William A.
    [J]. WATER RESEARCH, 2015, 84 : 161 - 170
  • [50] The formation of chlorine dioxide in the electrochemical treatment of drinking water for disinfection
    Bergmann, H
    Koparal, AS