Thrombolysis using multi-frequency high intensity focused ultrasound at MHz range: an in vitro study

被引:48
|
作者
Suo, Dingjie [1 ]
Guo, Sijia [1 ]
Lin, Weili [2 ,3 ]
Jiang, Xiaoning [1 ]
Jing, Yun [1 ]
机构
[1] N Carolina State Univ, Dept Mech & Aerosp Engn, Raleigh, NC 27695 USA
[2] Univ N Carolina, Dept Radiol, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Biomed Res Imaging Ctr, Chapel Hill, NC 27599 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2015年 / 60卷 / 18期
关键词
thrombolysis; multi-frequency HIFU; ultrasound; TISSUE-PLASMINOGEN ACTIVATOR; ENHANCED THROMBOLYSIS; TRANSCRANIAL ULTRASOUND; THERAPEUTIC ULTRASOUND; GAS-BUBBLES; CAVITATION; STROKE; SONOTHROMBOLYSIS; DEPENDENCE; EFFICACY;
D O I
10.1088/0031-9155/60/18/7403
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High intensity focused ultrasound (HIFU) based thrombolysis has emerged as a promising drug-free treatment approach for ischemic stroke. The large amount of acoustic power required by this approach, however, poses a critical challenge to the future clinical translation. In this study, multi-frequency acoustic waves at MHz range (near 1.5 MHz) were introduced as HIFU excitations to reduce the required power for treatment as well as the treatment time. In vitro bovine blood clots weighing around 150 mg were treated by single-frequency and multi-frequency HIFU. The pulse length was 2 ms for all experiments except the ones where the duty cycle was changed. It was found that dual-frequency thrombolysis efficiency was statistically better than single-frequency under the same acoustic power and excitation condition. When varying the acoustic power but fixing the duty cycle at 5%, it was found that dual-frequency ultrasound can save almost 30% power in order to achieve the same thrombolysis efficiency. In the experiment where the duty cycle was increased from 0.5% to 10%, it was shown that dual-frequency ultrasound can achieve the same thrombolysis efficiency with only half of the duty cycle of single-frequency. Dual-frequency ultrasound could also accelerate the thrombolysis by a factor of 2-4 as demonstrated in this study. No significant differences were found between dual-frequencies with different frequency differences (0.025, 0.05, and 0.1 MHz) and between dual-frequency and triple-frequency. The measured cavitation doses of dual-frequency and triple-frequency excitations were at about the same level but both were significantly higher than that of single-frequency.
引用
收藏
页码:7403 / 7418
页数:16
相关论文
共 50 条
  • [11] Thrombolysis enhanced by dual-frequency high-intensity focused ultrasound
    Guo, Sijia
    Suo, Dingjie
    Jing, Yun
    Jiang, Xiaoning
    Frank, Jonathan
    Lin, Weili
    [J]. 2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 2173 - 2176
  • [12] High intensity focused ultrasound at 3 mhz (hifu)
    Thueoff, S.
    Chaussy, C.
    [J]. EUROPEAN UROLOGY SUPPLEMENTS, 2007, 6 (02) : 293 - 293
  • [13] The safety of using high frequency, low intensity ultrasound to enhance thrombolysis
    Soltani, Azita
    [J]. Therapeutic Ultrasound, 2006, 829 : 233 - 237
  • [14] Machining of Aluminium with MHz High-Intensity Focused Ultrasound
    Pudas, Topi
    Hyvonen, Jere
    Holmstrom, Axi
    Sillanpaa, Tom
    Lassila, Petri
    Makinen, Joni
    Kuronen, Antti
    Kotiaho, Tapio
    Salmi, Ari
    Haeggstrom, Edward
    [J]. 2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [15] Frequency Optimization in High Intensity Focused Ultrasound
    Yetik, Hasan
    Ariyurek, Cemre
    Bozkurt, Ayhan
    Ergun, Arif Sanli
    [J]. 2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 409 - 412
  • [16] In Vitro Demonstration of Focused Ultrasound Thrombolysis Using Bifrequency Excitation
    Saletes, Izella
    Gilles, Bruno
    Auboiroux, Vincent
    Bendridi, Nadia
    Salomir, Rares
    Bera, Jean-Christophe
    [J]. BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [17] In vitro ablation of cardiac valves using high-intensity focused ultrasound
    Otsuka, R
    Fujikura, K
    Hirata, K
    Pulerwitz, T
    Oe, Y
    Suzuki, T
    Sciacca, R
    Marboe, C
    Wang, J
    Burkhoff, D
    Muratore, R
    Lizzi, FL
    Homma, S
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (01): : 109 - 114
  • [18] In Vitro Atrial Septal Ablation Using High-Intensity Focused Ultrasound
    Takei, Yasuyoshi
    Muratore, Robert
    Kalisz, Andrew
    Okajima, Kazue
    Fujimoto, Kohei
    Hasegawa, Takuya
    Arai, Kotaro
    Rekhtman, Yelena
    Berry, Grace
    Di Tullio, Marco R.
    Homma, Shunichi
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (04) : 467 - 472
  • [19] A Comparative Study of Fibroid Ablation Rates Using Radio Frequency or High-Intensity Focused Ultrasound
    Meng, Xin
    He, Guangbin
    Zhang, Jun
    Han, Zenghui
    Yu, Ming
    Zhang, Miaomiao
    Tang, Yu
    Fang, Ling
    Zhou, Xiaodong
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (04) : 794 - 799
  • [20] Hemostasis using high intensity focused ultrasound
    Vaezy, Shahram
    Martin, Roy
    Mourad, Pierre
    Crum, Lawrence
    [J]. European Journal of Ultrasound, 1999, 9 (01): : 79 - 87