3D-printed Handheld Models Do Not Improve Recognition of Specific Characteristics and Patterns of Three-part and Four-part Proximal Humerus Fractures

被引:8
|
作者
Spek, Reinier W. A. [1 ,2 ]
Schoolmeesters, Bram J. A. [1 ,2 ]
Oosterhoff, Jacobien H. F. [3 ,4 ]
Doornberg, Job N. [5 ,6 ]
van den Bekerom, Michel P. J. [7 ,8 ]
Jaarsma, Ruurd L. [1 ,2 ]
Eygendaal, Denise [9 ]
IJpma, Frank [6 ,10 ]
机构
[1] Flinders Univ S Australia, Dept Orthopaed Surg, Adelaide, SA, Australia
[2] Flinders Med Ctr, Adelaide, SA, Australia
[3] Harvard Med Sch, Massachusetts Gen Hosp, Dept Orthopaed Surg, Boston, MA 02115 USA
[4] Univ Amsterdam, Amsterdam Univ Med Ctr, Dept Orthopaed Surg, Amsterdam Movement Sci, Amsterdam, Netherlands
[5] Univ Groningen, Dept Orthopaed Surg, Groningen, Netherlands
[6] Univ Med Ctr Groningen, Groningen, Netherlands
[7] OLVG, Dept Orthopaed Surg, Shoulder & Elbow Expertise Ctr, Amsterdam, Netherlands
[8] Vrije Univ Amsterdam, Fac Behav & Movement Sci, Dept Human Movement Sci, Amsterdam Movement Sci, Amsterdam, Netherlands
[9] Univ Amsterdam, Amphia Hosp, Dept Orthopaed Surg, Med Ctr, Amsterdam, Netherlands
[10] Univ Groningen, Dept Trauma Surg, Groningen, Netherlands
关键词
INTEROBSERVER RELIABILITY; CLASSIFICATION;
D O I
10.1097/CORR.0000000000001921
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Reliably recognizing the overall pattern and specific characteristics of proximal humerus fractures may aid in surgical decision-making. With conventional onscreen imaging modalities, there is considerable and undesired interobserver variability, even when observers receive training in the application of the classification systems used. It is unclear whether three-dimensional (3D) models, which now can be fabricated with desktop printers at relatively little cost, can decrease interobserver variability in fracture classification. Questions/purposes Do 3D-printed handheld models of proximal humerus fractures improve agreement among residents and attending surgeons regarding (1) specific fracture characteristics and (2) patterns according to the Neer and Hertel classification systems? Methods Plain radiographs, as well as two-dimensional (2D) and 3D CT images, were collected from 20 patients (aged 18 years or older) who sustained a three-part or four-part proximal humerus fracture treated at a Level I trauma center between 2015 and 2019. The included images were chosen to comprise images from patients whose fractures were considered as difficult-to-classify, displaced fractures. Consequently, the images were assessed for eight fracture characteristics and categorized according to the Neer and Hertel classifications by four orthopaedic residents and four attending orthopaedic surgeons during two separate sessions. In the first session, the assessment was performed with conventional onscreen imaging (radiographs and 2D and 3D CT images). In the second session, 3D-printed handheld models were used for assessment, while onscreen imaging was also available. Although proximal humerus classifications such as the Neer classification have, in the past, been shown to have low interobserver reliability, we theorized that by receiving direct tactile and visual feedback from 3D-printed handheld fracture models, clinicians would be able to recognize the complex 3D aspects of classification systems reliably. Interobserver agreement was determined with the multirater Fleiss kappa and scored according to the categorical rating by Landis and Koch. To determine whether there was a difference between the two sessions, we calculated the delta (difference in the) kappa value with 95% confidence intervals and a two-tailed p value. Post hoc power analysis revealed that with the current sample size, a delta kappa value of 0.40 could be detected with 80% power at alpha = 0.05. Results Using 3D-printed models in addition to conventional imaging did not improve interobserver agreement of the following fracture characteristics: more than 2 mm medial hinge displacement, more than 8 mm metaphyseal extension, surgical neck fracture, anatomic neck fracture, displacement of the humeral head, more than 10 mm lesser tuberosity displacement, and more than 10 mm greater tuberosity displacement. Agreement regarding the presence of a humeral head-splitting fracture was improved but only to a level that was insufficient for clinical or scientific use (fair to substantial, delta kappa = 0.33 [95% CI 0.02 to 0.64]). Assessing 3D-printed handheld models adjunct to onscreen conventional imaging did not improve the interobserver agreement for pattern recognition according to Neer (delta kappa = 0.02 [95% CI -0.11 to 0.07]) and Hertel (delta kappa = 0.01 [95% CI -0.11 to 0.08]). There were no differences between residents and attending surgeons in terms of whether 3D models helped them classify the fractures, but there were few differences to identify fracture characteristics. However, none of the identified differences improved to almost perfect agreement (kappa value above 0.80), so even those few differences are unlikely to be clinically useful. Conclusion Using 3D-printed handheld fracture models in addition to conventional onscreen imaging of three-part and four-part proximal humerus fractures does not improve agreement among residents and attending surgeons on specific fracture characteristics and patterns. Therefore, we do not recommend that clinicians expend the time and costs needed to create these models if the goal is to classify or describe patients' fracture characteristics or pattern, since doing so is unlikely to improve clinicians' abilities to select treatment or estimate prognosis.
引用
收藏
页码:150 / 159
页数:10
相关论文
共 50 条
  • [21] Early results for treatment of three- and four-part fractures of the proximal humerus using the PHILOS plate system
    Moonot, P.
    Ashwood, N.
    Hamlet, M.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (09): : 1206 - 1209
  • [22] The Results of Nonoperative Treatment for Three- and Four-Part Fractures of the Proximal Humerus in Low-Demand Patients
    Yuksel, Halil Yalcin
    Yilmaz, Serdar
    Aksahin, Ertugrul
    Celebi, Levent
    Muratli, Hasan Hilmi
    Bicimoglu, Ali
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 (10) : 588 - 595
  • [23] Fixed-angle locked plating of two-, three-, and four-part proximal humerus fractures
    Badman, Brian L.
    Mighell, Mark
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2008, 16 (05) : 294 - +
  • [24] Level of physical activity in elderly patients after hemiarthroplasty for three- and four-part fractures of the proximal humerus
    Skutek, M
    Fremerey, RW
    Bosch, U
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1998, 117 (4-5) : 252 - 255
  • [25] Hemiarthroplasty for three- and four-part displaced fractures of the proximal humerus in patients over 65 years of age
    Pavlopoulos, Dimitrios A.
    Badras, Leonidas S.
    Georgiou, Christina S.
    Skretas, Efstathios F.
    Malizos, Konstantinos N.
    ACTA ORTHOPAEDICA BELGICA, 2007, 73 (03): : 306 - 314
  • [26] Comparison between reverse shoulder arthroplasty and Humerusblock in three- and four-part proximal humerus fractures in elderly patients
    Reinhold Ortmaier
    Georg Mattiassich
    Matthias Pumberger
    Wolfgang Hitzl
    Philipp Moroder
    Alexander Auffarth
    Herbert Resch
    International Orthopaedics, 2015, 39 : 335 - 342
  • [27] Reverse Total Shoulder Arthroplasty Demonstrates Better Outcomes Than Angular Stable Plate in the Treatment of Three-part and Four-part Proximal Humerus Fractures in Patients Older Than 70 Years
    Lanzetti, Riccardo Maria
    Gaj, Edoardo
    Berlinberg, Elyse J.
    Patel, Harsh H.
    Spoliti, Marco
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2023, 481 (04) : 735 - 747
  • [28] What Factors Are Associated With Poor Shoulder Function and Serious Complications After Internal Fixation of Three-part and Four-part Proximal Humerus Fracture-dislocations?
    Gavaskar, Ashok S.
    Pattabiraman, Kirubakaran
    Srinivasan, Parthasarathy
    Raj, Rufus, V
    Jayakumar, Balamurugan
    Rangasamy, Naveen Kumar
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2022, 480 (08) : 1566 - 1573
  • [29] Comparison of Treatment Options of Three- and Four-Part Humerus Proximal Fractures in Patients Over 50 Years of Age
    Erpala, Firat
    Tahta, Mesut
    Ozturk, Tahir
    Zengin, Cagatay
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (08)
  • [30] Comparison between reverse shoulder arthroplasty and Humerusblock in three- and four-part proximal humerus fractures in elderly patients
    Ortmaier, Reinhold
    Mattiassich, Georg
    Pumberger, Matthias
    Hitzl, Wolfgang
    Moroder, Philipp
    Auffarth, Alexander
    Resch, Herbert
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (02) : 335 - 342