Study on Measurement of Cl2 Emission Concentration by Differential Absorption Spectroscopy

被引:0
|
作者
Shi, Jiatong [1 ]
Guo, Jie [1 ]
Han, Xiaohong [1 ]
Yu, Zhiwei [1 ]
Zhang, Han [1 ]
机构
[1] Hangzhou Zetian Technol Co Ltd, Hangzhou 310052, Peoples R China
来源
关键词
differential optical absorption spectroscopy; broadband dielectric coated mirror; spectral measurement; Cl-2;
D O I
10.1117/12.2537544
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
An ultra-low emission Cl-2 monitoring optical system based on differential optical absorption spectroscopy has been set up. We have found through comparison experiments that UV reflection enhanced aluminum is damaged and the dielectric film mirror is intact under high concentration of Cl-2. Then verify the performance characteristics of ultra-low Cl-2 emission online monitoring device. The maximum absorbance of 50ppm Cl-2 exceeds 0.1, while the 30ppm Cl-2 reaches 0.063, so the measurement range can be 0-95 mg/m(3), which meets the maximum allowable emission concentration of Cl-2 required by the new regulations for detection of 65mg/m(3).
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Auger electron spectroscopy study of reactor walls in transition from an O2 to a Cl2 plasma
    Guha, Joydeep
    Donnelly, Vincent M.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2009, 27 (03): : 515 - 520
  • [42] Odorous Emission Monitoring Based on Differential Optical Absorption Spectroscopy
    Xue, Rui
    Li, Mingxuan
    Han, Xiaohong
    Guo, Jie
    Zhang, Han
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS VI, 2019, 11189
  • [43] Development of 100 μmol mol−1 Cl2 Standard Gas Mixture for Accurate Calibration of Ambient Cl2 Sensors and Stack Emission Monitors
    Jinsang Jung
    ByungMoon Kim
    Sanghyub Oh
    Asian Journal of Atmospheric Environment, 2020, 14 : 170 - 176
  • [44] Ammonia emission concentration measurement using laser absorption spectroscopy chamber system based on deep belief networks
    Yu, Dongqi
    Zhang, Yujun
    He, Ying
    You, Kun
    Fan, Boqiang
    Xie, Hao
    Zhang, Wangchun
    OPTICAL ENGINEERING, 2024, 63 (07)
  • [45] Measurement of absolute SiO concentration using UV absorption spectroscopy
    Coursimault, F
    Motret, O
    Viladrosa, R
    Pouvesle, JM
    JOURNAL DE PHYSIQUE IV, 2003, 108 : 131 - 134
  • [46] Influence of gas concentration inhomogeneity on measurement accuracy in absorption spectroscopy
    Komada, Pawel
    Cieszczyk, Slawomir
    Wojcik, Waldemar
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (08): : 36 - 38
  • [47] Measurement of elemental concentration of aerosols using spark emission spectroscopy
    Diwakar, Prasoon K.
    Kulkarni, Pramod
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (07) : 1101 - 1109
  • [48] Threshold photoelectron spectroscopy of Cl2 and Br2 up to 35 cV
    Yencha, A.J.
    Hopkirk, A.
    Hiraya, A.
    Donovan, R.J.
    Goode, J.G.
    Maier, R.R.J.
    King, G.C.
    Kvaran, A.
    Journal of Physical Chemistry, 1995, 99 (19):
  • [49] Measurement of low concentrations of NO2 gas by differential optical absorption spectroscopy method
    Al-Jalal, AbdulAziz
    Al-Basheer, Watheq
    Gasmi, Khaled
    Romadhon, Moch S.
    MEASUREMENT, 2019, 146 : 613 - 617
  • [50] Development of 100 μmol mol-1 Cl2 Standard Gas Mixture for Accurate Calibration of Ambient Cl2 Sensors and Stack Emission Monitors
    Jung, Jinsang
    Kim, ByungMoon
    Oh, Sanghyub
    ASIAN JOURNAL OF ATMOSPHERIC ENVIRONMENT, 2020, 14 (02) : 170 - 176