A New Columnar CsI(Tl) Scintillator for iQID detectors

被引:9
|
作者
Han, Ling [1 ]
Miller, Brian W. [1 ,3 ]
Barber, H. Bradford [1 ,2 ]
Nagarkar, Vivek V. [4 ]
Furenlid, Lars R. [1 ,2 ]
机构
[1] Univ Arizona, Coll Opt Sci, Tucson, AZ 85721 USA
[2] Univ Arizona, Dept Med Imaging, CGRI, Tucson, AZ 85721 USA
[3] Pacific NW Natl Lab, Richland, WA 99352 USA
[4] Radiat Monitoring Devices Inc, Watertown, MA 02472 USA
关键词
Columnar CsI(Tl); thick scintillator; iQID detector; sensitivity; resolution; depth of interaction; noise discrimination; frame parsing;
D O I
10.1117/12.2066179
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A 1650 mu m thick columnar CsI(Tl) scintillator for upgrading iQID detectors, which is a high-resolution photon-counting gamma-ray and x-ray detector recently developed at the Center for Gamma-Ray Imaging (CGRI), has been studied in terms of sensitivity, spatial resolution and depth-of-interaction effects. To facilitate these studies, a new frame-parsing algorithm for processing raw event data is also proposed that has more degrees of freedom in data processing and can discriminate against a special kind of noise present in some low-cost intensifiers. The results show that in comparison with a 450 mu m-thickness columnar CsI(Tl) scintillator, the 1650 mu m thick CsI(Tl) scintillator provides more than twice the sensitivity at the expense of some spatial resolution degradation. The depth-of-interaction study also shows that event size and amplitude vary with scintillator thickness, which can assist in future detector simulations and 3D-interaction-position estimation.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] LiF/CsI:Tl Scintillator for High-Resolution Neutron Imaging
    Miller, Stuart R.
    Marshall, Matthew S. J.
    Wart, Megan
    Bilheux, Hassina Z.
    Santodonato, Louis J.
    Riedel, Rick
    Nagarkar, Vivek V.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2019, 66 (10) : 2261 - 2264
  • [32] Properties of Vacuum Deposited CsI(Tl) and ZnSe(Te) Scintillator Layers
    Fedorov, Alexander
    Katrunov, Konstantin
    Lalayants, Alexander
    Lebedinsky, Alexey
    Shiran, Natalia
    Mateychenko, Pavel
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 955 - 957
  • [33] Packing Conditions of Optical Separated CsI: Tl Scintillator by Silicon Collimator
    Ohtake, R.
    Tabata, K.
    Nishizawa, J.
    Koike, A.
    Aoki, T.
    4TH INTERNATIONAL CONFERENCE ON NANOTECHNOLOGIES AND BIOMEDICAL ENGINEERING, ICNBME-2019, 2020, 77 : 735 - 739
  • [34] Applications of a pnCCD detector coupled to columnar structure CsI(Tl) scintillator system in ultra high energy X-ray Laue diffraction
    Shokr, M.
    Schlosser, D.
    Abboud, A.
    Algashi, A.
    Tosson, A.
    Conka, T.
    Hartmann, R.
    Klaus, M.
    Genzel, C.
    Strueder, L.
    Pietsch, U.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [35] CsI(Tl) scintillators as γ-ray detectors for the identification of hidden explosives
    Fioretto, E
    Tiana, M
    Innocenti, F
    Viesti, G
    Cinausero, M
    Coco, I
    Fabris, D
    Filippini, V
    Lunardon, M
    Nebbia, G
    Prete, G
    Pesente, S
    Bohus, LS
    Chukhaev, E
    Melnikov, AI
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2): : 234 - 238
  • [36] CsI(Tl) + photodiode scintillation assemblies for γ-ray and proton detectors
    A. M. Kudina
    Yu. A. Borodenkoa
    B. V. Grinyova
    A. V. Didenkoa
    A. V. Dudnikb
    B. G. Zaslavskya
    E. Valtonenc
    T. Eronenc
    J. Peltonend
    J. Lehtid
    H. Kettunene
    A. Virtanene
    J. Huovelin
    Instruments and Experimental Techniques, 2010, 53 : 39 - 44
  • [37] LIGHT OUTPUT OF CSI(TL) THIN-FILM DETECTORS
    LEVCHENKO, VF
    SARTBAEV, T
    SKREBTSOV, GP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1977, 20 (01) : 56 - 57
  • [38] THE OPTIMIZATION OF SMALL CSI(TL) GAMMA-RAY DETECTORS
    BIRD, AJ
    CARTER, T
    DEAN, AJ
    RAMSDEN, D
    SWINYARD, BM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 395 - 399
  • [39] Improved energy resolution for scintillator based gamma-ray detectors obtained using a CsI(Tl)/Si-PIN detector
    Patt, BE
    Iwanczyk, JS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (10): : 3926 - 3927
  • [40] Silicon Photomultiplier and CsI(Tl) scintillator in application to portable H*(10) dosimeter
    Buzhan, P.
    Karakash, A.
    Teverovskiy, Yu.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 912 : 245 - 247