Hand-held fans: Physical Properties and Perceptions of Patients with COPD

被引:6
|
作者
Smith, Tracy A. [1 ]
Cho, Jin-Gun
Roberts, Mary M.
Swami, Vinita
Wheatley, John R.
机构
[1] Westmead Hosp, Dept Resp & Sleep Med, POB 533, Wentworthville 2145, Australia
关键词
Dyspnea; Palliative Care; Patient preference; Pulmonary Disease; Chronic Obstructive; Fans; ADVANCED CANCER; AIR-FLOW; DYSPNEA; BREATHLESSNESS; FEASIBILITY; DISEASE;
D O I
10.1016/j.jpainsymman.2021.07.006
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Rationale. Patients with chronic obstructive pulmonary disease (COPD) may remain breathless despite optimal medical treatment. Hand-held fans (HHFs) are recommended to relieve breathlessness, but little is known about physical properties of different fans and the impact HHF properties may have on patient perceptions of fans. Objective. To describe the physical properties of HHFs and investigate the relationship of these properties to patient fan preference. Methods. We recruited 33 participants with COPD who were attending a pulmonary rehabilitation program. Participants trialled 5 HHFs in random order. Participants rated perceived airflow, pleasantness of airflow, noisiness, and ease of use of each fan using a 1-10 numerical rating scale (NRS). After trialling all 5 fans, participants ranked each HHF from best (5 arbitrary units; a.u.) to worst (1 a.u.). Rankings for each fan were tallied to produce total HHF scores (T-HHF; maximum=165 a.u.). Objective measurements were made of sound intensity (dB; sound level meter), airflow between 5cm and 30cm from the middle of the fan (anemometer), blade rotation speed, blade size and total fan weight. We assessed the strength of association of T-HHF scores against mean NRS values using Spearman correlation coefficients and used linear regression to compare measured to perceived airflow, and noisiness to sound intensity. Results. Participants were 68.5 +/- 8.9 years (mean +/- SD), 63% male, with a median FEV1 of 0.99L(IQR 0.76-1.31L). There was considerable variability between the 5 fans tested in terms of participant perceptions and physical properties with an almost 5-fold difference in air velocity at 30cm and a 3-fold difference in blade rotation speed. The most preferred fan had a T-HHF score of 140 and had the highest airflow (1.9 m/s) measured at 30cm. T-HHF score positively correlated with pleasantness of airflow (r = 0.46; P < 0.001), perceived airflow (r=0.58; P<0.001) and airflow velocity at 30cm from fan blades (r=1.0; P = 0.02). There were positive linear relationships between fan airflow velocity and perceived air amount, and between measured sound intensity and perceived noisiness(both P<0.001). Women reported significantly higher perceived airflow than men (P < 0.001). Conclusions. The physical properties of the five included HHFs are quite distinct. Patient preference was related to pleasantness of airflow, perceived airflow, and measured airflow at 30cm. Gender differences in perceived airflow were noted. Future research should explore the relationship between HHF characteristics and relief of breathlessness. J Pain Symptom Manage 2022;63:e9-e16. (c) 2021 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:E9 / E16
页数:8
相关论文
共 50 条
  • [21] Friction properties of the face of a hand-held tennis racket
    Maeda, Hiroshi
    Okauchi, Masaaki
    [J]. ENGINEERING OF SPORT CONFERENCE 2012, 2012, 34 : 544 - 549
  • [22] Promoting physical activity through hand-held computer technology
    King, Abby C.
    Ahn, David K.
    Oliveira, Brian M.
    Atienza, Audie A.
    Castro, Cynthia M.
    Gardner, Christopher D.
    [J]. AMERICAN JOURNAL OF PREVENTIVE MEDICINE, 2008, 34 (02) : 138 - 142
  • [23] HAND-HELD ECHOCARDIOGRAPHY IS VASTLY SUPERIOR TO PHYSICAL EXAMINATION BY CARDIOLOGISTS IN PATIENTS REFERRED FOR ECHOCARDIOGRAPHY
    Mehta, Manish
    Jacobson, Timothy
    Peters, Dawn
    Le, Dai-Trang
    Belcik, Todd
    Kaul, Sanjiv
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1083 - E1083
  • [24] PROPERTIES OF HAND-HELD SPREADERS AFTER SIMULATED USE
    SVEC, TA
    POWERS, JM
    [J]. JOURNAL OF ENDODONTICS, 1995, 21 (08) : 411 - 414
  • [25] PROPERTIES OF HAND-HELD SPREADERS AFTER SIMULATED USE
    SVEC, T
    POWERS, JM
    [J]. JOURNAL OF DENTAL RESEARCH, 1994, 73 : 409 - 409
  • [26] Evaluation of an electronic hand-held spirometer in patients with asthma
    Hamid, S
    Corden, ZM
    Ryan, DP
    Burnett, I
    Cochrane, GM
    [J]. RESPIRATORY MEDICINE, 1998, 92 (10) : 1177 - 1180
  • [27] Investigating the potential of hand-held expiratory flow meters in COPD screening programmes
    Beecroft, Simon
    Masters, Nigel
    Tutt, Catherine
    [J]. PRIMARY CARE RESPIRATORY JOURNAL, 2011, 20 (04): : 359 - 359
  • [28] THE BROWSER - A HAND-HELD BRAILLER
    VISSER, E
    [J]. JOURNAL OF VISUAL IMPAIRMENT & BLINDNESS, 1994, 88 (06) : 568 - 568
  • [29] A simple hand-held spectrometer
    Daw, HA
    [J]. AMERICAN JOURNAL OF PHYSICS, 1997, 65 (03) : 251 - 254
  • [30] Hand-held homogenization tool
    Kido, Horacio
    [J]. Genetic Engineering and Biotechnology News, 2013, 33 (08): : 24 - 25