摘要
A mercury analyzer (Model SMS 100) was evaluated for the direct determination of mercury in whole human blood samples. The instrument is based on sample combustion in an oxygen-rich furnace, elimination of interferences in a catalytic furnace, mercury concentration by amalgamation with gold, and the release of mercury vapor and its transport in a stream of oxygen to the measurement cell. Mercury determination is performed by atomic absorption spectrometry at 253.7 nm. In order to obtain complete combustion of the blood sample without loss of mercury, all operating conditions were optimized. The temperatures and times of the combustion step were critical to avoid spluttering of the sample. It was found that the samples of whole human blood, the certified reference material of human blood, and the aqueous standards showed different behavior in this step. The optimized condition for the combustion step was 650 degrees C for 60 seconds. The temperatures and times for the other steps were also optimized. The calibration and the analytical performance of the method were also studied. The detection limit obtained for mercury was 0.02 ng, and the relative standard deviations were between 1.1 and 3.2%. The proposed method is an interesting approach to the determination of mercury in whole human blood samples, because sample dissolution with wet digestion methods is not necessary, resulting in the ability to analyze an important number (approximately 7) of samples per hour.
引用
收藏
页码:102 / 106
页数:5
相关论文
共 50 条
  • [31] DETERMINATION OF VOLATILE MERCURY-COMPOUNDS IN AIR WITH THE COLEMAN MERCURY ANALYZER SYSTEM
    DUMAREY, R
    HEINDRYCKX, R
    DAMS, R
    HOSTE, J
    ANALYTICA CHIMICA ACTA, 1979, 107 (JUN) : 159 - 167
  • [32] THE DIRECT DETERMINATION OF MERCURY IN URINE
    ROBINSON, JW
    SKELLY, EM
    SPECTROSCOPY LETTERS, 1983, 16 (02) : 117 - 132
  • [33] THE DIRECT DETERMINATION OF MERCURY IN SWEAT
    ROBINSON, JW
    SKELLY, EM
    SPECTROSCOPY LETTERS, 1983, 16 (02) : 133 - 150
  • [34] DETERMINATION OF MERCURY CONTENT OF HUMAN BLOOD BY ACTIVATION ANALYSIS
    KELLERSHOHN, C
    COMAR, D
    LEPOEC, C
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1965, 66 (01): : 168 - +
  • [35] Use of a direct mercury analyzer® for mercury speciation in different matrices without sample preparation
    Windmoller, Claudia Carvalhinho
    Silva, Nayara Carolinne
    Morais Andrade, Pedro Henrique
    Mendes, Louise Aparecida
    do Valle, Claudia Magalhaes
    ANALYTICAL METHODS, 2017, 9 (14) : 2159 - 2167
  • [36] ASSESSMENT OF MERCURY LEVEL IN LOCAL POLISH AND IMPORTED HONEYS WITH USE OF DIRECT MERCURY ANALYZER
    Tomczyk, Monika
    Kusibab, Julita
    Zachara, Alicja
    Dzugan, Malgorzata
    JOURNAL OF APICULTURAL SCIENCE, 2023, 67 (01) : 5 - 13
  • [37] Comparison of direct mercury analyzer and FIA-CV-AAS in determination of methylmercury in fish
    Ulrich, J. C.
    Hortellani, M. A.
    Sarkis, J. E. S.
    Nakatsubo, M. A.
    8TH BRAZILIAN CONGRESS ON METROLOGY (METROLOGIA 2015), 2016, 733
  • [38] How small can you go? Using a direct mercury analyzer to measure mercury in vibrissae of Steller sea lions
    Gastaldi, Angela
    Bishop, Amanda
    Rea, Lorrie D.
    MARINE MAMMAL SCIENCE, 2023, 39 (03) : 1005 - 1010
  • [39] Quantification and speciation of mercury in streams and rivers sediment samples from Paracatu, MG, Brazil, using a direct mercury analyzer®
    Rezende, Patricia Sueli
    Silva, Nayara Carolinne
    Moura, William Douglas
    Windmoller, Claudia Carvalhinho
    MICROCHEMICAL JOURNAL, 2018, 140 : 199 - 206