Comparison of fracture loads of CAD/CAM and conventionally fabricated temporary fixed dental prostheses after different aging regimens

被引:0
|
作者
Edelhoff, D. [1 ]
Schraml, D. [1 ]
Eichberger, M. [1 ]
Stawarczyk, B. [1 ]
机构
[1] Klinikum Univ Munchen, Poliklin Zahnarztl Prothet, Campus Innenstadt,Goethestr 70, D-80336 Munich, Germany
关键词
chewing simulation; fracture load; PMMA; polymeric CAD/CAM materials; temporary restorations; BEARING CAPACITY; LABORATORY SIMULATION; RESTORATIONS; TEMPERATURE; COMPOSITE; DESIGN; RESINS; HOT;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated the fracture loads of different three unit fixed dental prostheses (FDPs) for temporary restorations. In total, three CAD/CAM materials (VITA CAD Temp [CT], Telio CAD [TC], and ZENO ProFix [ZP]) and two chairside materials (Protemp 4 [PT], and Dentalon Plus [DP]) were used for the fabrication of the FDPs. Sixteen FDPs were fabricated from each material in an anatomical shape and stored in 0.9% NaCl solution at 37 degrees C for 14 days. Thereafter, one half of the specimens from each group (n = 8) were additionally mechanically and thermally loaded (240,000 chewing cycles, 50 N, 5 degrees/55 degrees C, 2,100 thermal cycles). Fracture loads were measured and data analyzed using two- and one-way ANOVA, followed by Scheffe's post hoc test. ZP showed the highest mean fracture loads, regardless of the aging regime. Significantly lowest values were identified for DP and TC within the non-thermal loaded group, and for PT and CT within the thermal loaded group. No negative impact of aging regimes could be observed.
引用
收藏
页码:101 / 112
页数:12
相关论文
共 50 条
  • [21] First clinical experiences with CAD/CAM-fabricated PMMA-based fixed dental prostheses as long-term temporaries
    Fabian Huettig
    Andreas Prutscher
    Christoph Goldammer
    Curt A. Kreutzer
    Heiner Weber
    Clinical Oral Investigations, 2016, 20 : 161 - 168
  • [22] Comparison of clinical fit of three-unit zirconia fixed prostheses fabricated using chairside and labside CAD/CAM systems
    Ahn, Jong-Ju
    Bae, Eun-Bin
    Lee, Wan-Sun
    Cho, Won-Tak
    Huh, Jung-Bo
    JOURNAL OF DENTAL SCIENCES, 2020, 15 (02) : 239 - 242
  • [23] Zirconia fixed dental prostheses fabricated by 3D gel deposition show higher fracture strength than conventionally milled counterparts
    Rabel, Kerstin
    Nold, Julian
    Pehlke, Daniela
    Shen, James
    Abram, Anze
    Kocjan, Andraz
    Witkowski, Siegbert
    Kohal, Ralf -Joachim
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 135
  • [24] Fracture Strength of Six-Unit Anterior Fixed Provisional Restorations Fabricated Using Various Dental CAD/CAM Systems
    Yoon, Gyu-Won
    Park, Eun-Jin
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 : S49 - S54
  • [25] Fracture resistance of endocrowns made from different CAD/CAM materials after prolonged fatigue aging
    Dincturk, B. Arslandas
    Garoushi, Sufyan
    Alp, C. Kedici
    Vallittu, Pk
    Uctasli, M. B.
    Lassila, L.
    CLINICAL ORAL INVESTIGATIONS, 2025, 29 (03)
  • [26] Effect of placement strategies and connector designs in CAD/CAM technology on fracture resistance of multilayered monolithic zirconia fixed dental prostheses: An in vitro study
    Bakitian, Fahad
    Dental Materials Journal, 2024, 43 (05) : 693 - 700
  • [27] Mechanical analysis of three-unit metal-free fixed dental prostheses produced in different materials with CAD/CAM technology
    Demirci, Fatih
    Bahce, Erkan
    Baran, Melike Cigdem
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (09) : 5969 - 5978
  • [28] Mechanical analysis of three-unit metal-free fixed dental prostheses produced in different materials with CAD/CAM technology
    Fatih Demirci
    Erkan Bahce
    Melike Cigdem Baran
    Clinical Oral Investigations, 2022, 26 : 5969 - 5978
  • [29] Influence of different convergence angles of abutment teeth and cement spaces on internal adaptation of anterior CAD-CAM fixed dental prostheses
    Ito, Keigo
    Iwasaki, Taro
    Kitani, Jin
    Honda, Junichi
    Kubochi, Kei
    Komine, Futoshi
    JOURNAL OF ORAL SCIENCE, 2024, 66 (01) : 55 - 59
  • [30] Precision Fit of Screw-Retained Implant-Supported Fixed Dental Prostheses Fabricated by CAD/CAM, Copy-Milling, and Conventional Methods
    de Franca, Danilo Gonzaga B.
    Morais, Maria Helena S. T.
    das Neves, Flavio D.
    Carreiro, Adriana da Fonte P.
    Barbosa, Gustavo A. S.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (03) : 507 - 513