Comparison of quality control between PET/MRI and PET/CT systems using NEMA tests

被引:0
|
作者
Abuqbeitah, M. [1 ]
Demir, M. [1 ]
Yeyin, N. [1 ]
Toklu, T. [2 ]
Sezgin, S. [3 ]
Cetin, H. [3 ]
Sonmezoglu, K.
机构
[1] Istanbul Univ, Istanbul, Turkey
[2] Yeditepe Univ, Nucl Med Dept, Istanbul, Turkey
[3] Epsilon Lab, Istanbul, Turkey
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OP-619
引用
收藏
页码:S340 / S341
页数:2
相关论文
共 50 条
  • [1] Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests
    Demir, Mustafa
    Toklu, Turkay
    Abuqbeitah, Mohammad
    Cetin, Huseyin
    Sezgin, H. Sezer
    Yeyin, Nami
    Sonmezoglu, Kerim
    MOLECULAR IMAGING AND RADIONUCLIDE THERAPY, 2018, 27 (01) : 10 - 18
  • [2] Investigation of tumor assessment between two PET systems using various indices: comparison between PET/CT and PET/MRI systems
    Hotsumi, Hirotoshi
    Ishii, Shirou
    Suenaga, Hiroki
    Sugawara, Shigeyasu
    Fukushima, Kenji
    Ito, Hiroshi
    AMERICAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 13 (04): : 156 - 163
  • [3] A Clinical and Experimental Comparison of Time of Flight PET/MRI and PET/CT Systems
    Oprea-Lager, Daniela E.
    Yaqub, Maqsood
    Pieters, Indra C.
    Reinhard, Rinze
    van Moorselaar, Reindert J. A.
    van den Eertwegh, Alfons J. M.
    Hoekstra, Otto S.
    Lammertsma, Adriaan A.
    Boellaard, Ronald
    MOLECULAR IMAGING AND BIOLOGY, 2015, 17 (05) : 714 - 725
  • [4] A Clinical and Experimental Comparison of Time of Flight PET/MRI and PET/CT Systems
    Daniela E. Oprea-Lager
    Maqsood Yaqub
    Indra C. Pieters
    Rinze Reinhard
    Reindert J. A. van Moorselaar
    Alfons J. M. van den Eertwegh
    Otto S. Hoekstra
    Adriaan A. Lammertsma
    Ronald Boellaard
    Molecular Imaging and Biology, 2015, 17 : 714 - 725
  • [5] Investigation of acquisition time for harmonization of image quality between PET/CT and PET/MRI systems: A phantom study
    Yoon, Seok Hwan
    Park, Chan Rok
    OPTIK, 2021, 244
  • [6] Quality control in PET/CT and PET/MRI: Results of a survey amongst European countries
    Reynes-Llompart, Gabriel
    Zorz, Alessandra
    Boellaard, Ronald
    Ptacek, Jaroslav
    Pike, Lucy
    Soret, Marine
    Vandenberghe, Stefaan
    Matheoud, Roberta
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 99 : 16 - 21
  • [7] Comparison of PET/CT with Sequential PET/MRI Using an MR-Compatible Mobile PET System
    Nakamoto, Ryusuke
    Nakamoto, Yuji
    Ishimori, Takayoshi
    Fushimi, Yasutaka
    Kido, Aki
    Togashi, Kaori
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (05) : 846 - 851
  • [8] Evaluation of PET quantitation accuracy among multiple discovery IQ PET/CT systems via NEMA image quality test
    Vallot, Delphine
    De Ponti, Elena
    Morzenti, Sabrina
    Gramek, Anna
    Pieczonka, Anna
    Llompart, Gabriel Reynes
    Siennicki, Jakub
    Deak, Paul
    Dutta, Chiranjib
    Uribe, Jorge
    Caselles, Olivier
    EJNMMI PHYSICS, 2020, 7 (01)
  • [9] Comparison of NEMA characterizations for Discovery MI and Discovery MI-DR TOF PET/CT systems at different sites and with other commercial PET/CT systems
    Alexandre Chicheportiche
    Rami Marciano
    Marina Orevi
    EJNMMI Physics, 7
  • [10] Quality control in PET/CT systems: experiences and requirements
    Geworski, Lilli
    Karwarth, Cornelia
    Fitz, Eduard
    Plotkin, Michail
    Knoop, Bernd
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2010, 20 (01): : 46 - 50