Characterization of an optically stimulated dosimeter for dentomaxillofacial dosimetry

被引:4
|
作者
Valiyaparambil, Jayasanker V. [2 ]
Mallya, Sanjay M. [1 ]
机构
[1] Univ Calif Los Angeles, Div Diagnost & Surg Sci, Sch Dent, Los Angeles, CA 90095 USA
[2] Univ Connecticut, Sch Dent Med, Storrs, CT 06269 USA
关键词
COMPUTED-TOMOGRAPHY; LUMINESCENCE; DEVICES;
D O I
10.1016/j.tripleo.2011.06.024
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The objective of this study was to examine the suitability of optically stimulated luminescent dosimeters (OSLD) for point dosimetry of maxillofacial radiographic examinations. Study design. The dose response of OSLD nanoDot dosimeters was evaluated over the range of 10 mu Gy to 4900 mu Gy x-radiation. The angular dependence of the OSLD nanoDots was examined and compared with that of thermoluminescent dosimeter (TLD) chips. The concordance between OSDL- and TLD-measured absorbed doses at selected anatomic sites in an anthropomorphometric phantom was examined. Results. OSLD-measured doses were not significantly different from the actual delivered dose, as determined by an ionization chamber. The dose response is linear over the dose response over the examined dose range. Angular variation of OSLD dosimeters ranged from 88% to 109%; however, the magnitude of this variation was not significantly different from that of TLDs. There was a good concordance between OSLD- and TLD-measured absorbed doses. Conclusions. The OSLD nanoDots dosimeter system performs as well as currently used TLD systems and effective dose estimates using this new system did not differ significantly from current TLD-based dose estimates. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;112:793-797)
引用
收藏
页码:793 / 797
页数:5
相关论文
共 50 条
  • [22] Optically stimulated luminescence dosimeter based on CaS:Eu,Sm
    Liu Yanping
    Chen Zhaoyang
    Ba Weizhen
    Fan Yanwei
    Guo Qi
    Yu Xuefeng
    Chang Aiming
    Lu Wu
    Du Yanzhao
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2008, 19 (02) : 113 - 116
  • [23] Ultra-Violet Annealing of Optically Stimulated Luminescent Dosimeter
    Lam, K.
    Lee, C.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3721 - 3721
  • [24] Optically stimulated luminescence dosimeter based on CaS:Eu,Sm
    LIU Yanping~(1
    [J]. Nuclear Science and Techniques, 2008, (02) : 113 - 116
  • [25] Metal-organic frameworks as optically stimulated luminescence dosimeter
    Joshi, Shailesh
    Panda, Madhusmita
    Annalakshmi, O.
    Srinivas, C. Venkata
    Venkatraman, B.
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024,
  • [26] Optically Stimulated Light Dosimetry: Commissioning of An Optically Stimulated Luminescence (OSL) System for Remote Dosimetry Audits, the Radiological Physics Center Experience
    Aguirre, J.
    Alvarez, P.
    Followill, D.
    Ibbott, G.
    Amador, C.
    Tailor, A.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [27] Dosimetric characterization of optically stimulated luminescence dosimeter with therapeutic photon beams for use in clinical radiotherapy measurements
    Ponmalar, Retna
    Manickam, Ravikumar
    Ganesh, K. M.
    Saminathan, Sathiyan
    Raman, Arun
    Godson, Henry Finlay
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2017, 13 (02) : 304 - 312
  • [28] Optically stimulated luminescence and its use in medical dosimetry
    Akselrod, M. S.
    Botter-Jensen, L.
    McKeever, S. W. S.
    [J]. RADIATION MEASUREMENTS, 2006, 41 : S78 - S99
  • [29] Magnesium aluminate spinel for optically stimulated luminescence dosimetry
    Pan, L.
    Sholom, S.
    McKeever, S. W. S.
    Jacobsohn, L. G.
    [J]. JOURNAL OF ALLOYS AND COMPOUNDS, 2021, 880
  • [30] Online dosimetry based on optically stimulated luminescence materials
    Vaillé, JR
    Ravotti, F
    Garcia, P
    Glaser, M
    Matias, S
    Idri, K
    Boch, J
    Lorfèvre, E
    McNulty, PJ
    Saigné, E
    Dusseau, L
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (06) : 2578 - 2582