Synthetic Aperture Imaging in Breast Ultrasound: A Preliminary Clinical Study

被引:11
|
作者
Kim, Won Hwa [1 ]
Chang, Jung Min [1 ]
Kim, Choye [2 ]
Park, Jongho [2 ]
Yoo, Yangmo [3 ]
Moon, Woo Kyung [1 ]
Cho, Nariya [1 ]
Choi, Byung Ihn [1 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul 100744, South Korea
[2] Sogang Univ, Dept Elect Engn, Seoul, South Korea
[3] Sogang Univ, Interdisciplinary Program Integrated Biotechnol, Seoul, South Korea
关键词
Ultrasound; synthetic aperture imaging; breast lesions; CODED EXCITATION; SONOGRAPHY; SYSTEMS; LESIONS; MOTION;
D O I
10.1016/j.acra.2012.04.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To compare the image quality between conventional and synthetic aperture (SA) imaging in breast ultrasound (US). Materials and Methods: Twenty-four patients with 31 breast lesions were included in our study. The US data were processed with SA algorithm. For quantitative analysis, contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated. For qualitative analysis, conventional and SA images were reviewed by three radiologists and diagnostic preference (conspicuity, margin sharpness, and contrast) was assessed. The radiologists also determined whether artifacts were present. Parameters were analyzed using a paired t-test, Wilcoxon signed-rank test, and chi-square test. Results: The mean CNRs were higher in SA images compared with conventional images (mean, 2.56 versus 2.28, P=.004). The mean SNRs were higher in SA images compared with conventional images (31.62 versus 25.26, P <.0001). SA images were considered as being "better" or "much better" in 16-23 (51.6-74.2%) lesions of total 31 lesions for conspicuity, in 17-24 (45.2%-77.4%) for margin sharpness, and in 13-23 (41.9%-74.2%) for contrast. Significant preferences in SA images were demonstrated (conspicuity, P <.05 for all radiologists; margin sharpness and contrast in two radiologists). Refraction and speckle artifacts were less frequently observed in SA images (refraction, P <.05 for all radiologists; speckle, P <.05 for two radiologists), whereas reflection artifacts were more frequent in SA images (P <.05 in two radiologists). Conclusion: SA imaging provides better image quality than conventional imaging in patients with focal breast lesions in breast US.
引用
收藏
页码:923 / 929
页数:7
相关论文
共 50 条
  • [1] Synthetic aperture ultrasound imaging
    Jensen, Jorgen Arendt
    Nikolov, Svetoslav Ivanov
    Gammelmark, Kim Lokke
    Pedersen, Morten Hogholm
    ULTRASONICS, 2006, 44 : E5 - E15
  • [2] SYNTHETIC APERTURE ULTRASOUND IMAGING
    CRIBBS, RW
    MAHONY, JE
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (04): : 262 - 262
  • [3] Evaluation of a Synthetic Aperture Technique for Medical Ultrasound Imaging: Phantom and in vivo Breast study
    Kim, Choye
    Yoon, Changhan
    Kim, Won Hwa
    Chang, Jung Min
    Song, Tai-Kyung
    Yoo, Yangmo
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1287 - 1290
  • [4] Evaluation of Ultrasound Synthetic Aperture Imaging Using Bidirectional Pixel-Based Focusing: Preliminary Phantom and In Vivo Breast Study
    Kim, Choye
    Yoon, Changhan
    Park, Jong-Ho
    Lee, Yuhwa
    Kim, Won Hwa
    Chang, Jung Min
    Choi, Byung Ihn
    Song, Tai-Kyong
    Yoo, Yang-Mo
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (10) : 2716 - 2724
  • [5] Synthetic Transmit Aperture in Ultrasound Imaging
    Trots, Ihor
    Nowicki, Andrzej
    Lewandowski, Marcin
    ARCHIVES OF ACOUSTICS, 2009, 34 (04) : 685 - 695
  • [6] Synthetic Aperture Imaging in Ultrasound Calibration
    Ameri, Golafsoun
    Baxter, John S. H.
    McLeod, A. Jonathan
    Jayaranthe, Uditha
    Chen, Elvis C. S.
    Peters, Terry M.
    MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [7] Synthetic aperture ultrasound imaging with a ring transducer array: preliminary ex vivo results
    Xiaolei Qu
    Takashi Azuma
    Takeshi Yogi
    Shiho Azuma
    Hideki Takeuchi
    Satoshi Tamano
    Shu Takagi
    Journal of Medical Ultrasonics, 2016, 43 : 461 - 471
  • [8] Synthetic Aperture Ultrasound Imaging with Classified Aperture Coherence Factors
    Zhao, Jinxin
    Wang, Jin
    Wang, Yuanyuan
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (05) : 1013 - 1020
  • [9] Synthetic aperture ultrasound imaging with a ring transducer array: preliminary ex vivo results
    Qu, Xiaolei
    Azuma, Takashi
    Yogi, Takeshi
    Azuma, Shiho
    Takeuchi, Hideki
    Tamano, Satoshi
    Takagi, Shu
    JOURNAL OF MEDICAL ULTRASONICS, 2016, 43 (04) : 461 - 471
  • [10] Parametric Beamformer for Synthetic Aperture Ultrasound Imaging
    Nikolov, Svetoslav I.
    Tomov, Borislav G.
    Jensen, Jorgen A.
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 2172 - 2176