Assessment of Damping Control Using Maximum Power Point Tracking Methods for Heaving Wave Energy Converters

被引:0
|
作者
Mon, Bisni Fahad [1 ]
Wahyudie, Addy [1 ,2 ]
Jama, Mohammed Abdi [3 ]
Akbar, Siddiqul [2 ]
Mekhilef, Saad [4 ,5 ]
Shareef, Hussain [1 ]
Harib, Khalifa [6 ]
Errouissi, Rachid [1 ]
机构
[1] United Arab Emirates Univ UAE U, Dept Elect Engn, Al Ain, U Arab Emirates
[2] United Arab Emirates Univ, Natl Water & Energy Ctr NWEC, Al Ain, U Arab Emirates
[3] Abu Dhabi Univ, Dept Elect Engn, Al Ain, U Arab Emirates
[4] Swinburne Univ Technol, Sch Sci Comp & Engn Technol, Hawthorn, Vic 3122, Australia
[5] Univ Malaya, Dept Elect Engn, Kuala Lumpur 50603, Malaysia
[6] United Arab Emirates Univ, Dept Mech Engn, Al Ain, U Arab Emirates
关键词
Maximum power point trackers; Force; Mathematical models; Damping; Springs; Load modeling; Performance analysis; Damping control; hardware-in-the-loop; hill-climbing method; maximum power point tracking; perturb and observe algorithm; wave energy converters; LINEAR GENERATOR; SYSTEM;
D O I
10.1109/ACCESS.2021.3135601
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
There are not many studies conducted in the implementation of maximum power point tracking (MPPT) methods for heaving wave energy converters (WECs). An assessment of damping control using various MPPT methods for heaving WEC was conducted in this study. Damping control was implemented using a DC-DC boost converter. The duty cycle for MPPT was determined using a perturb and observe algorithm. This assessment study determines the following for applying MPPT for heaving WECs: best location for the observing parameters; best performance index for the MPPT; and effect of averaging the performance index. Three locations for the observing parameters (mechanical parameters near the source, electrical parameters at the load, and electrical parameters between the source and load) and three performance indices (maximising power, minimising impedance, and maximising admittance) were assessed and evaluated. Finally, the effects of applying the running mean and conventional instantaneous value on the performance index were compared. Various scenarios using nine MPPT methods were tested using simulated regular and irregular sea states. The test results were validated experimentally using a simple and low-cost hardware-in-the-loop (HIL) scheme. The HIL scheme was developed using off-the-shelf devices that can be used for any topology of WECs. The results showed that the MPPT method has an optimum performance by using the performance index for maximising power, using observing parameters between the source and the load, and deploying conventional instantaneous values for the observing parameters.
引用
收藏
页码:168907 / 168921
页数:15
相关论文
共 50 条
  • [41] Maximum Power Point Tracking Using Model Reference Adaptive Control
    Khanna, Raghav
    Zhang, Qinhao
    Stanchina, William E.
    Reed, Gregory F.
    Mao, Zhi-Hong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) : 1490 - 1499
  • [42] Comparison of Maximum Power Point Tracking Methods for Medium to High Power Wind Energy Systems
    Heydari, Mojtaba
    Smedley, Keyue
    2015 20TH CONFERENCE ON ELECTRICAL POWER DISTRIBUTION NETWORKS CONFERENCE (EPDC), 2015, : 184 - 189
  • [43] A Hill-Climbing-Method-Based Maximum-Power-Point-Tracking Strategy for Direct-Drive Wave Energy Converters
    Xiao, Xi
    Huang, Xuanrui
    Kang, Qing
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (01) : 257 - 267
  • [44] Research on maximum power point tracking control of acoustic energy harvest system
    Gu, Cong
    Chen, Yuansheng
    Jiang, Kun
    AIP ADVANCES, 2021, 11 (02)
  • [45] Maximum Power Point Tracking Methods for the Solar Battery
    Belova, Irina A.
    Martinovich, Miroslav, V
    Skolota, Vladimir A.
    Zaev, Ilya, V
    2018 19TH INTERNATIONAL CONFERENCE OF YOUNG SPECIALISTS ON MICRO/NANOTECHNOLOGIES AND ELECTRON DEVICES (EDM 2018), 2018, : 445 - 451
  • [46] Maximum Power Point Tracking in Wind Energy Conversion Systems Using Tracking Control System Based on Fuzzy Controller
    Mahdavian, M.
    Wattanapongsakorn, N.
    Shahgholian, G.
    Mozafarpoor, S. H.
    Janghorbani, M.
    Shariatmadar, S. M.
    2014 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2014,
  • [47] Multivariable maximum power point tracking for photovoltaic micro-converters using extremum seeking
    Ghaffari, Azad
    Seshagiri, Sridhar
    Krstic, Miroslav
    CONTROL ENGINEERING PRACTICE, 2015, 35 : 83 - 91
  • [48] Nonlinear control with wave observer to maximize harvested power for point absorber wave energy converters
    Do, Duc Khac
    ASIAN JOURNAL OF CONTROL, 2022, 24 (01) : 16 - 45
  • [49] Damping Control of Heaving Wave Energy Harvester Using a Single-Switch Boost Rectifier Circuit
    Jama, Mohammed
    Wahyudie, Addy
    2018 OCEANS - MTS/IEEE KOBE TECHNO-OCEANS (OTO), 2018,
  • [50] Increasing osmotic power and energy with maximum power point tracking
    Maisonneuve, Jonathan
    Chintalacheruvu, Sanjana
    APPLIED ENERGY, 2019, 238 : 683 - 695