Aortic valve replacement with stentless porcine aortic valves: A ten-year experience

被引:0
|
作者
David, TE
Feindel, CM
Scully, HE
Bos, J
Rakowski, H
机构
[1] Toronto Hosp, Div Cardiovasc Surg, Toronto, ON M5T 2S8, Canada
[2] Univ Toronto, Toronto, ON, Canada
来源
JOURNAL OF HEART VALVE DISEASE | 1998年 / 7卷 / 03期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aims of the study: It has been shown that although stentless porcine aortic valves have better hemodynamic features than stented porcine valves, their long-term durability remains unknown. This study was undertaken to examine the long-term clinical outcome of aortic valve replacement (AVR) with stentless porcine aortic valves. Methods: Between 1987 and 1989, custom-made stentless valves were implanted in 29 patients (mean age 58 years), and between 1991 and 1997, the Toronto SPV was implanted in 213 patients (mean age 63 years). In addition to AVR, one-third of the patients had coronary artery bypass. All patients were followed up at annual intervals and underwent Doppler echocardiography. Results: There were two operative and 11 late deaths (four cardiac, seven non-cardiac). The actuarial survival rate was 89 +/- 4% at nine years. There were two strokes and seven transient ischemic attacks; freedom from thromboembolic complications was 92 +/- 4% at nine years. Two patients developed infective endocarditis, one early and one late; freedom from prosthetic valve endocarditis was 98 +/- 1% at nine years. Freedom from primary tissue failure was 85 +/- 8% at nine years. Seven patients required repeat AVR, because of endocarditis (two) and aortic insufficiency (five); freedom from repeat AVR was 82 +/- 8% at nine years. Periodic hemodynamic assessment by echocardiography indicated that the mean systolic gradients across the valve decreased during the first year of implantation, the valve effective orifice increased, and valve competence remained stable. Conclusions: Stentless porcine aortic valves have provided excellent clinical results. These valves may suffer degenerative changes and fail at the same rate as stented porcine aortic valves but, because of their superior hemodynamic performance, they may enhance patients' survival by allowing complete regression of left ventricular hypertrophy and restoration of normal ventricular function.
引用
收藏
页码:250 / 254
页数:5
相关论文
共 50 条
  • [31] Aortic valve replacement with a bioprosthesis in patients with severe aortic stenosis. Stented or stentless valves?
    Andres Rodriguez-Caulo, Emiliano
    Garcia-Borbolla, Mariano
    Velazquez, Carlos J.
    Castro, Antonio
    Miranda, Nuria
    Ramirez, Bella
    Garcia-Borbolla, Rafael
    Gutierrez, Maria A.
    Perez-Duarte, Enrique
    Tellez, Juan C.
    Araji, Omar
    Barquero, Jose M.
    [J]. CIRUGIA CARDIOVASCULAR, 2013, 20 (01): : 18 - 24
  • [32] Stentless xenografts for aortic valve replacement
    Doty, JR
    Doty, DB
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (02) : 240 - 251
  • [33] Stentless aortic valve replacement: an update
    Kobayashi, Junjiro
    [J]. VASCULAR HEALTH AND RISK MANAGEMENT, 2011, 7 : 345 - 351
  • [34] ECHOCARDIOGRAPHIC ASSESSMENT OF AORTIC-VALVE REPLACEMENT WITH STENTLESS PORCINE XENOGRAFTS
    MELONI, L
    RICCHI, A
    CIRIO, E
    FALCHI, S
    ABBRUZZESE, PA
    ARU, GM
    MARTELLI, V
    ROSS, D
    CHERCHI, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (04): : 294 - 296
  • [35] AORTIC-VALVE REPLACEMENT WITH A STENTLESS PORCINE BIOPROSTHESIS - MULTICENTER TRIAL
    DELRIZZO, DF
    GOLDMAN, BS
    DAVID, TE
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 1995, 11 (07) : 597 - 603
  • [36] Ten-Year Experience with Transapical and Direct Transaortic Transcatheter Aortic Valve Replacement to Address Patients with Aortic Stenosis and Peripheral Vascular Disease
    Ferrari, Enrico
    Pozzoli, Alberto
    Klersy, Catherine
    Toto, Francesca
    Torre, Tiziano
    Cassina, Tiziano
    Pedrazzini, Giovanni
    Demertzis, Stefanos
    [J]. JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2022, 9 (12)
  • [37] Aortic valve repair: a ten-year single-centre experience DISCUSSION
    Ngaage, D.
    Dr Mangini
    Hanke, T.
    Kappetein, P.
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 19 (01) : 34 - 35
  • [38] Ten-Year Experience with a Transapical Approach for Transcatheter Aortic and Mitral Valve Implantation
    Galeone, Antonella
    Perrone, Fabiola
    Pesarini, Gabriele
    Ribichini, Flavio Luciano
    Di Gaetano, Renato
    Luciani, Giovanni Battista
    Onorati, Francesco
    [J]. JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2024, 11 (07)
  • [39] CLINICAL-EXPERIENCE WITH STENTLESS PERICARDIAL AORTIC MONOPATCH FOR AORTIC-VALVE REPLACEMENT
    BATISTA, RJV
    DOBRIANSKIJ, A
    COMAZZI, M
    NETO, LTL
    ROCHA, G
    SARTORI, F
    WESTPHAL, R
    TIMI, JR
    MOREIRA, R
    OLIVEIRA, PF
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1987, 93 (01): : 19 - 26
  • [40] Minimally Invasive Aortic Valve Replacement (AVR) with Stentless Pericardial Valves (SPV): Three Years Experience
    Repossini, A.
    Costetti, A.
    Ciobanu, A. M.
    Moggi, A.
    Chiari, E.
    Muneretto, C.
    [J]. CARDIOLOGY, 2012, 121 (02) : 133 - 133