A study of radon and thoron release from Egyptian building materials using polymeric nuclear track detectors

被引:39
|
作者
Hafez, AF [1 ]
Hussein, AS
Rasheed, NM
机构
[1] Univ Alexandria, Fac Sci, Dept Phys, Alexandria 21511, Egypt
[2] Nucl Mat Author, Cairo, Egypt
关键词
radon; thoron; polymeric track detectors; building materials; Egypt;
D O I
10.1016/S0969-8043(00)00281-5
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The free exhalation rates of both thoron and radon, the specific activities of Ra-224, and Ra-226, and the physical properties, such as the emanation coefficients and radon effective diffusion coefficient of several building material samples were determined using LR-115 and CR-39 polymeric nuclear track detectors. The free areal exhalation rate was measured by the sealed cup-technique, whereas the radium content was obtained by the alpha-autoradiographic method. The calibration coefficient for thoron measurements in air using cylindrical cup equipped with LR-115 detector was estimated. Moreover, the calibration coefficients for measurements of the specific activities of Ra-224 and 226Ra were also evaluated. New method was developed for evaluating the emanation coefficient as well as the diffusion coefficient of radon isotopes in the studied materials. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:291 / 298
页数:8
相关论文
共 50 条
  • [11] Radon exhalation studies in building materials using solid-state nuclear track detectors
    Ajay Kumar
    Surinder Singh
    Pramana, 2004, 62 : 143 - 146
  • [12] Radon diffusion studies in some building materials using solid state nuclear track detectors
    Singh, S
    Kumar, J
    Singh, B
    Singh, J
    RADIATION MEASUREMENTS, 1999, 30 (04) : 461 - 464
  • [13] A STUDY OF RADON EMITTED FROM BUILDING-MATERIALS USING PLASTIC ALPHA-TRACK DETECTORS
    ABUJARAD, F
    FREMLIN, JH
    BULL, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 683 - 694
  • [14] The analysis of results of radon/thoron measurements performed with the use of nuclear track detectors
    Chalupnik, Stanislaw
    JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (04) : N39 - N45
  • [15] RADON AND THORON DOSIMETRY BY PLASTIC SOLID-STATE NUCLEAR TRACK DETECTORS
    KHAN, HA
    AKBER, RA
    BUKHARI, KM
    SADDARUDIN, A
    NUCLEAR INSTRUMENTS & METHODS, 1977, 147 (01): : 125 - 131
  • [16] Radon exhalation rate in building materials using plastic track detectors
    D. Amrani
    D. E. Cherouati
    Journal of Radioanalytical and Nuclear Chemistry, 1999, 242 : 269 - 271
  • [17] Radon exhalation rate in building materials using plastic track detectors
    Amrani, D
    Cherouati, DE
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1999, 242 (02) : 269 - 271
  • [18] RADON MEASUREMENTS IN COAL-MINES USING POLYMERIC NUCLEAR TRACK DETECTORS
    TUFAIL, M
    MATIULLAH
    ALI, A
    ORFI, SD
    QURESHI, AA
    HUSSAIN, G
    KHAN, HA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1988, 15 (1-4): : 655 - 658
  • [19] Radiological Impact of Radon and Thoron Levels in Dwellings Measured using Solid State Nuclear Track Detectors
    Singh, Bhupender
    Kanta, Krishan
    Garg, Maneesha
    Singh, Ajit
    Sahoo, B. K.
    Sapra, B. K.
    ADVANCES IN BASIC SCIENCES (ICABS 2019), 2019, 2142
  • [20] A new method for studying the transport of radon and thoron in various building materials using CR-39 and LR-115 solid state nuclear track detectors
    Misdaq, MA
    Ktata, A
    Bakhchi, A
    RADIATION MEASUREMENTS, 2000, 32 (01) : 35 - 42