Experimental study of the swing compressor with two discharge channels for household air-conditioner applications

被引:5
|
作者
Pan, Xi [1 ]
Pan, Shulin [2 ]
Zhang, Hanyue [1 ]
Xie, Junlong [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 417000, Peoples R China
[2] Hunan Univ Humanities Sci & Technol, Sch Energy & Elect Engn, Loudi 417000, Peoples R China
关键词
Swing compressor; Two discharge channels; Isentropic efficiency; Volumetric efficiency; COP; LEAKAGE CHARACTERISTICS; MODEL; PUMP;
D O I
10.1016/j.ijrefrig.2021.09.024
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a novel swing compressor with two discharge channels (SCTC) is introduced, which can be an alternative compressor applied in household air-conditioner. SCTC has two discharge ports. The first one without discharge valve operates at all shaft speed and the other one with a high stiffness discharge valve operates at high shaft speed, which is helpful to improve the service life of compressor and discharge valve. Additionally, the discharge close volume is eliminated and the liquid strike can be prevented. In order to obtain the performance of SCTC, a prototype has been tested at three different shaft speeds and its volumetric efficiency, adiabatic efficiency, COP and noise characteristic have been analyzed. The performance of SCTC is always better than that of the swing compressor with no valve (SCNV). Besides, compared with the conventional swing compressor, the COP of SCTC increases by 2.26% at the shaft speed of 1800 r.min(-1).
引用
收藏
页码:56 / 62
页数:7
相关论文
共 50 条
  • [31] Design of a Variable Speed Compressor Drive System for Air-Conditioner without Electrolytic Capacitor
    Yoo, Hyunjae
    Sul, Seung-Ki
    Jang, Hoyong
    Hong, Youngho
    CONFERENCE RECORD OF THE 2007 IEEE INDUSTRY APPLICATIONS CONFERENCE FORTY-SECOND IAS ANNUAL MEETING, VOLS. 1-5, 2007, : 305 - +
  • [32] Experimental study on the effect of air outflow parameters of wall mounted air-conditioner on the indoor thermal environment
    Lai, Y. H.
    Zhang, J. G.
    Guo, L.
    Lin, Charlie
    Lu, M. X.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 492 - 498
  • [33] Experimental investigations on the thermal characteristics of a multi-functional air-conditioner
    Qiu, Fuqiang
    Du, Juanli
    Xu, Taoping
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2023, 18 : 218 - 227
  • [34] Experimental investigations on the thermal characteristics of a multi-functional air-conditioner
    Qiu, Fuqiang
    Du, Juanli
    Xu, Taoping
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2023, 18 : 218 - 227
  • [35] Experimental study on multi-split air conditioner with digital scroll compressor
    Tu, Qiu
    Dong, Kaijun
    Zou, Deqiu
    Lin, Yongman
    APPLIED THERMAL ENGINEERING, 2011, 31 (14-15) : 2449 - 2457
  • [36] Experimental study of the effects of the cycle characteristics on the refrigerant-induced noise in system air-conditioner
    Weui Bong Jeong
    Hyung Suk Han
    Jin Yong Mo
    Jae Kwon Lee
    Journal of Mechanical Science and Technology, 2007, 21 : 1112 - 1119
  • [37] Experimental study on the effect of the split-type air-conditioner on the transmission of smoking pollutants in a room
    Xie, Ruoyi
    Xu, Yiyang
    Chen, Guangming
    Zhang, Shaozhi
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2022, 72 (10) : 1113 - 1120
  • [38] Experimental study of the effects of the cycle characteristics on the refrigerant-induced noise in system air-conditioner
    Jeong, Weui Bong
    Han, Hyung Suk
    Mo, Jin Yong
    Lee, Jae Kwon
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2007, 21 (07) : 1112 - 1119
  • [39] Experimental Investigations on a Conventional Air-conditioner Working as Air-water Heat Pump
    Wang, Yu
    You, Yuwen
    Zhang, Zhigang
    PEEA 2011, 2011, 23
  • [40] Development of CBN Internal Grinding Machine for Precision Grinding of the Air-conditioner Compressor Piston Hole
    Zheng, Y. G.
    Liu, W. G.
    Jiang, B.
    Gao, H.
    Zheng, Sh. G.
    ADVANCES IN ABRASIVE TECHNOLOGY XII, 2009, 76-78 : 43 - +