Experimental Study of Perfobond Rib Shear Connector under Lateral Force

被引:4
|
作者
Wang, Xuewei [1 ]
He, Qiuxia [1 ]
An, Zhiwen [1 ]
Liu, Guojun [1 ]
Wen, Xingke [1 ]
Wang, Yongqiang [1 ]
Zhong, Zhenxiao [1 ]
机构
[1] Sichuan Agr Univ, Sch Civil Engn, Chengdu 611830, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 19期
关键词
Perfobond rib shear connector; experimental study; push-out tests; lateral force; SEMIRIGID COMPOSITE FRAMES; STEEL; BEHAVIOR; RESISTANCE; STRENGTH; GIRDERS;
D O I
10.3390/app11199088
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A series of full-scale pushed out tests were performed on the Perfobond rib shear connector. The tests were designed to examine the performance of the Perfobond rib shear connector under different rib hole sizes and shapes, reinforcing bar sizes, rib thicknesses, as well as the presence of lateral forces. It has been revealed from the test results that the rib hole size and reinforcement diameter may not act independently, and the influence of one's size is actually dependent on the size of the other one. The lateral forces also affect the performance of the shear connector; for example, the capacity of the shear connector would be larger under compression than under tension. The existence of transverse pretension stress accelerated the cracking of concrete, leading to the strength and stiffness of concrete, perforated plate, and reinforcing rebars unable to fully exert their effect. In addition, the constraint effect of transverse stress improved the strength and stiffness of concrete and delayed the concrete cracking, bringing the strength and stiffness of concrete, perforated plate, and reinforcing rebars into full play, and resulting in a significant improvement in the shear capacity of Perfobond rib shear connectors.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Experimental Evaluation of the Shear Resistance of Corrugated Perfobond Rib Shear Connections
    Kim, Sang-Hyo
    Ahn, Jin-Hee
    Choi, Kyu-Tae
    Jung, Chi-Young
    ADVANCES IN STRUCTURAL ENGINEERING, 2011, 14 (02) : 249 - 263
  • [22] Shear Resistance of Perfobond Rib Shear Connectors under Cyclic Loading
    Zhao, Canhui
    Wang, Yuechen
    Zhu, Shengchun
    Deng, Kailai
    Li, Zhixiang
    Yuan, Xing
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (02)
  • [23] Experimental shear strength evaluation of perfobond shear connector with various hole shapes
    Zheng, Shuangjie
    Zhao, Chen
    Liu, Yuqing
    STRUCTURAL ENGINEERING AND MECHANICS, 2018, 67 (02) : 131 - 142
  • [24] Evaluation of fibre-reinforced polymer perfobond rib shear connector resistance tests
    Kolpasky, L.
    Ryjacek, P.
    ADVANCES AND TRENDS IN ENGINEERING SCIENCES AND TECHNOLOGIES II, 2017, : 159 - 164
  • [25] Predicting the capacity of perfobond rib shear connector using an ANN model and GSA method
    Guorui SUN
    Jun SHI
    Yuang DENG
    Frontiers of Structural and Civil Engineering, 2022, 16 (10) : 1233 - 1248
  • [26] Application of a Perfobond Rib Shear Connector Group in a Beam-Arch Hybrid Bridge
    Xu, Fei
    Zhang, Zhe
    Wang, Dehui
    Wang, Huili
    STRUCTURAL ENGINEERING INTERNATIONAL, 2015, 25 (04) : 414 - 418
  • [27] Predicting the capacity of perfobond rib shear connector using an ANN model and GSA method
    Sun, Guorui
    Shi, Jun
    Deng, Yuang
    FRONTIERS OF STRUCTURAL AND CIVIL ENGINEERING, 2022, 16 (10) : 1233 - 1248
  • [28] Bearing mechanisms of perfobond rib shear connectors by experimental investigation
    Meng, Hao
    Xu, Rongqiao
    ENGINEERING STRUCTURES, 2025, 326
  • [29] Experimental and Parametric Study on the Pull-Out Resistance of a Notched Perfobond Shear Connector
    Zheng, Shuangjie
    Liu, Yuqing
    Liu, Yangqing
    Zhao, Chen
    APPLIED SCIENCES-BASEL, 2019, 9 (04):
  • [30] Perfobond shear connector for composite construction
    Medberry, SB
    Shahrooz, BM
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 2002, 39 (01): : 2 - 12