Determination of Reference Geometry for Polyethylene Tibial Insert Wear Analysis

被引:16
|
作者
Teeter, Matthew G. [1 ,2 ]
Naudie, Douglas D. R. [1 ,3 ]
Milner, Jaques S. [1 ]
Holdsworth, David W. [1 ,2 ,3 ]
机构
[1] Univ Western Ontario, Imaging Res Labs, Robarts Res Inst, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, Schulich Sch Med & Dent, London, ON N6A 5K8, Canada
[3] Univ Western Ontario, Div Orthoped Surg, Schulich Sch Med & Dent, London, ON N6A 5K8, Canada
来源
JOURNAL OF ARTHROPLASTY | 2011年 / 26卷 / 03期
基金
加拿大健康研究院;
关键词
total knee arthroplasty; polyethylene wear; micro-computed tomography; wear analysis; retrieval studies;
D O I
10.1016/j.arth.2010.01.096
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Geometric wear analysis techniques require unworn geometries to serve as a reference in wear measurement. A method to create a reference geometrical model is described for retrieval studies when the actual unworn geometry is unavailable. Never-implanted tibial inserts were scanned with micro-computed tomography. Two, 3, or 6 insert surfaces were coaligned and averaged to create reference geometries. Individual inserts were compared with each other (manufacturing variability) and with the reference geometries (reference variability). The 3-dimensional deviations between the surfaces were recorded. The reference variability was reduced to 8.3 +/- 39 mu m, vs manufacturing variability of 15 +/- 59 mu m. Deviations were smallest on the articular surfaces where most wear occurs and were significantly less than the reported insert wear rate of 20 mu m/y.
引用
收藏
页码:497 / 503
页数:7
相关论文
共 50 条
  • [21] Polyethylene insert exchange for wear after toad shoulder arthroplasty
    Cheung, Emilie V.
    Sperling, John W.
    Cofield, Robert H.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (05) : 574 - 578
  • [22] Failure Analysis of Ultra-High Molecular Weight Polyethylene Tibial Insert in Total Knee Arthroplasty
    Manescu , Veronica
    Antoniac, Iulian
    Antoniac, Aurora
    Paltanea, Gheorghe
    Miculescu, Marian
    Bita, Ana-Iulia
    Laptoiu, Stefan
    Niculescu, Marius
    Stere, Alexandru
    Paun, Costel
    Cristea, Mihai Bogdan
    MATERIALS, 2022, 15 (20)
  • [23] Simulated normal gait wear testing of a highly cross-linked polyethylene tibial insert (vol 22, pg 435, 2007)
    不详
    JOURNAL OF ARTHROPLASTY, 2008, 23 (01): : 158 - 158
  • [24] Five-year migration and insert wear of uncemented tibial components with either conventional polyethylene or sequentially annealed highly crosslinked polyethylene inserts: a blinded randomized controlled trial using radiostereometric analysis
    de Ridder, R.
    Kaptein, B. L.
    Pijls, B. G.
    Nelissen, R. G. H. H.
    Kaptijn, H. H.
    BONE & JOINT JOURNAL, 2023, 105B (05): : 518 - 525
  • [25] The incidence of modular tibial polyethylene insert exchange in total knee arthroplasty when polyethylene failure occurs
    Bert, JM
    Reuben, J
    Kelly, F
    Gross, M
    Elting, J
    JOURNAL OF ARTHROPLASTY, 1998, 13 (06): : 609 - 614
  • [26] Nontraumatic, Spontaneous Dislocation of Polyethylene Tibial Insert 1 Year After TKA
    Wright, Russell C.
    Crouch, Andrew
    Yacoubian, Stephan V.
    Ravan, Raymond B., III
    Falkinstein, Yuri
    Yacoubian, Shahan V.
    ORTHOPEDICS, 2011, 34 (12) : 1002 - 1002
  • [27] Isolated Tibial Polyethylene Insert Exchange Outcomes After Total Knee Arthroplasty
    Willson, Seann E.
    Munro, Michelle L.
    Sandwell, Julie C.
    Ezzet, Kace A.
    Colwell, Clifford W., Jr.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) : 96 - 101
  • [28] Angled polyethylene insert exchange for sagittal tibial malalignment in total knee arthroplasty
    Sah, Alexander P.
    Scott, Richard D.
    Iorio, Richard
    JOURNAL OF ARTHROPLASTY, 2008, 23 (01): : 141 - 144
  • [29] MULTIPLE DAMAGE OF THE TIBIAL POLYETHYLENE INSERT IN KNEE JOINT PROSTHESIS (CAN EXCELLENT POSTOPERATIVE OUTCOME BE THE CAUSE OF THE TIBIAL INSERT FRACTURE?) Case report and review
    Song, Eun-Kyoo
    Eshnazarov, Kamolhuja
    Asilova, Saodat
    Seon, Jong-Keun
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2016, 22 (01): : 124 - 128
  • [30] Comparison of Tibial Insert Polyethylene Damage in Rotating Hinge and Highly Constrained Total Knee Arthroplasty: A Retrieval Analysis
    Bali, Kamal
    Naudie, Douglas D.
    Howard, James L.
    McCalden, Richard W.
    MacDonald, Steven J.
    Teeter, Matthew G.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (01): : 290 - 294