Determination of Reference Geometry for Polyethylene Tibial Insert Wear Analysis

被引:16
|
作者
Teeter, Matthew G. [1 ,2 ]
Naudie, Douglas D. R. [1 ,3 ]
Milner, Jaques S. [1 ]
Holdsworth, David W. [1 ,2 ,3 ]
机构
[1] Univ Western Ontario, Imaging Res Labs, Robarts Res Inst, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, Schulich Sch Med & Dent, London, ON N6A 5K8, Canada
[3] Univ Western Ontario, Div Orthoped Surg, Schulich Sch Med & Dent, London, ON N6A 5K8, Canada
来源
JOURNAL OF ARTHROPLASTY | 2011年 / 26卷 / 03期
基金
加拿大健康研究院;
关键词
total knee arthroplasty; polyethylene wear; micro-computed tomography; wear analysis; retrieval studies;
D O I
10.1016/j.arth.2010.01.096
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Geometric wear analysis techniques require unworn geometries to serve as a reference in wear measurement. A method to create a reference geometrical model is described for retrieval studies when the actual unworn geometry is unavailable. Never-implanted tibial inserts were scanned with micro-computed tomography. Two, 3, or 6 insert surfaces were coaligned and averaged to create reference geometries. Individual inserts were compared with each other (manufacturing variability) and with the reference geometries (reference variability). The 3-dimensional deviations between the surfaces were recorded. The reference variability was reduced to 8.3 +/- 39 mu m, vs manufacturing variability of 15 +/- 59 mu m. Deviations were smallest on the articular surfaces where most wear occurs and were significantly less than the reported insert wear rate of 20 mu m/y.
引用
收藏
页码:497 / 503
页数:7
相关论文
共 50 条
  • [1] Tibial insert undersurface as a contributing source of polyethylene wear debris
    Wasielewski, RC
    Parks, N
    Williams, I
    Surprenant, H
    Collier, JP
    Engh, G
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1997, (345) : 53 - 59
  • [2] Polyethylene wear on the distal tibial insert surface in total knee arthroplasty
    Gabriel, SM
    Dennis, DA
    Honey, MJ
    Scott, RD
    KNEE, 1998, 5 (03): : 221 - 228
  • [3] Manufacturing lot affects polyethylene tibial insert volume, thickness, and surface geometry
    Teeter, Matthew G.
    Milner, Jaques S.
    MacDonald, Steven J.
    Naudie, Douglas D. R.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (08) : 884 - 889
  • [4] Isolated Tibial Polyethylene Insert Exchange After Total Knee Arthroplasty for Treatment of Instability and/or Polyethylene Wear
    Alexander, Jacob S.
    Richardson, Eleanor
    Crawford, David A.
    Berend, Keith R.
    Morris, Michael J.
    Lombardi, Adolph V., Jr.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2023, 42
  • [5] Comparison of Polyethylene Tibial Insert Damage from In Vivo Function and In Vitro Wear Simulation
    Harman, Melinda K.
    DesJardins, John
    Benson, Lisa
    Banks, Scott A.
    LaBerge, Martine
    Hodge, W. Andrew
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2009, 27 (04) : 540 - 548
  • [6] Simulated normal gait wear testing of a highly cross-linked polyethylene tibial insert
    Muratoglu, Orhun K.
    Rubash, Harry E.
    Bragdon, Charles R.
    Burroughs, Brian R.
    Huang, Anna
    Harris, William H.
    JOURNAL OF ARTHROPLASTY, 2007, 22 (03): : 435 - 444
  • [7] Micromotion between the tibial tray and the polyethylene insert
    Sosa, MA
    Wasielewski, RC
    Litsky, AS
    PROCEEDINGS OF THE 1996 FIFTEENTH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE, 1996, : 210 - 213
  • [9] Tibial polyethylene insert mobility in mobile bearing total knee: a radiological analysis
    Castel, E
    Roger, B
    Camproux, A
    Saillant, G
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1999, 85 (01): : 33 - 41
  • [10] CATASTROPHIC WEAR OF TIBIAL POLYETHYLENE INSERTS
    KILGUS, DJ
    MORELAND, JR
    FINERMAN, GAM
    FUNAHASHI, TT
    TIPTON, JS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1991, (273) : 223 - 231